Daikin UATY18KTAL [31/87] Heating capacity 50hz

Daikin UATY09KTAL [31/87] Heating capacity 50hz
Capacity Tables ED43-441
30 Packaged Air Conditioners UATY-K Series
7.2 Heating Capacity [50Hz]
UATY06KY1
UATY08KY1
(m³/min.)
(˚CDB)
(kW)
(kW)
Symbols:
AFR
EDB
TC
PI
: Air flow rate
: Entering dry bulb temp.
: Total heating capacity
: Power input
(Comp.+outdoor fan motor).
Notes:
1. Direct interpolation is permissible.
Do not extrapolate beyond the Operation Limits.
2. shows nominal capacities.
3. Capacities are based on the following conditions.
Outdoor air : 85% RH. However, the condition on nominal capacity is
7˚CDB/6˚CWB.
4. Above heating capacities include indoor fan motor heat.
3D014896A
AFR
47
52
62
EDB(˚C)
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
TC
13.8
13.7
13.7
13.7
13.7
13.7
13.8
13.8
13.7
13.7
13.7
13.7
13.8
13.8
13.7
13.7
13.7
13.7
PI
4.4
4.5
4.7
4.8
4.9
5.1
4.3
4.4
4.6
4.7
4.8
5.0
4.2
4.3
4.5
4.5
4.6
4.8
TC
16.7
16.7
16.6
16.6
16.6
16.5
16.7
16.7
16.6
16.6
16.6
16.5
16.8
16.7
16.7
16.7
16.6
16.3
PI
4.8
5.0
5.1
5.2
5.3
5.5
4.7
4.8
5.0
5.1
5.2
5.4
4.5
4.7
4.8
4.9
5.0
5.1
TC
18.3
18.2
18.1
18.1
18.1
18.0
18.3
18.3
18.2
18.1
18.1
18.0
18.4
18.4
18.3
18.2
18.2
18.1
PI
5.0
5.2
5.3
5.4
5.5
5.7
4.9
5.0
5.2
5.3
5.4
5.6
4.7
4.8
5.0
5.1
5.2
5.4
TC
20.3
20.2
20.1
20.1
20.0
19.9
20.4
20.3
20.2
20.1
20.1
20.0
20.6
20.4
20.3
20.3
20.2
20.1
PI
5.3
5.5
5.7
5.8
5.9
6.1
5.2
5.3
5.5
5.6
5.7
5.9
4.9
5.1
5.3
5.4
5.5
5.7
TC
22.8
22.8
22.7
22.6
22.9
22.9
22.8
22.7
23.1
23.1
23.0
22.9
PI
6.2
6.3
6.4
6.6
6.0
6.1
6.2
6.4
5.7
5.8
5.9
6.1
-5 0 6 10 15
Indoor air
Outdoor temp. (˚CWB)
3D014900A
(m³/min.)
(˚CDB)
(kW)
(kW)
Symbols:
AFR
EDB
TC
PI
: Air flow rate
: Entering dry bulb temp.
: Total heating capacity
: Power input
(Comp.+outdoor fan motor).
Notes:
1. Direct interpolation is permissible.
Do not extrapolate beyond the Operation Limits.
2. shows nominal capacities.
3. Capacities are based on the following conditions.
Outdoor air : 85% RH. However, the condition on nominal capacity is
7˚CDB/6˚CWB.
4. Above heating capacities include indoor fan motor heat.