Daikin UAT240CGXY1 [10/16] Model uat150 180 240 300c
![Daikin UAT240CGXY1 [10/16] Model uat150 180 240 300c](/views2/1694809/page10/bga.png)
8
Model
Power cable
(mm
2
)
Breaker
capacity(A)
Over current
protection switch (A)
Earth cable
(mm
2
)
UAT150C 16 48 63 16
UAT180C 25 57 63 25
UAT240C 35 72.5 80 35
UAT300C 35 85 100 35
Note:
A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated
in fixed wiring in accordance with local and national legislation.
The unit is to be wired directly from an electrical distribution board either by a circuit breaker (preferred) or
HRC fuse.
Fix the power supply wiring to control module. Connect control wiring to control terminal block through the
control box’s hole.
Earth wiring must be connected.
The power supply cord must be equivalent to H07RN-F which is the minimum requirement, and to be used in
protective tube.
•
•
•
•
•
Model: UAT150/180/240/300C
Control wire
Terminal block
Power cable
CONTROL
BOX
(2) Wiring connection to unit
Route the power supply wires and control wire through the holes in the unit.
Remove the service panels and connect the units power supply wires to terminal block inside the control box, as
shown.
Make use of push releasable cable ties which are located at the bottom of control box to hold the power supply
wires properly
•
•
•
Terminal block
(3) Wiring Example And Selection Of Circuit Breaker
Note:
While installing the circuit breaker onto the unit, make sure that the screws do not damage the components
(e.g. coil) inside the unit.
•
1 IM RTC-0712(0)-DAIKIN-EN.indd 81 IM RTC-0712(0)-DAIKIN-EN.indd 8 8/10/12 11:25:58 AM8/10/12 11:25:58 AM
Содержание
- Installation manual 1
- Center of gravity 3
- English 3
- Model uat150c 3
- Model uat180c 3
- Original instruction 3
- Outline and dimensions 3
- 1672 147 4
- 1672 158 4
- Center of gravity 4
- Model uat240c 4
- Model uat300c 4
- Outline and dimensions 4
- English 5
- Installation manual 5
- Notice 5
- Safety precautions 5
- Warning caution 5
- Refrigerant circuit diagram 6
- Caution 7
- English 7
- Installation of the unit 7
- Electrical data 9
- English 9
- Physical data 9
- Wire connection 9
- Model uat150 180 240 300c 10
- Caution 11
- English 11
- Model uat150c 11
- Warning 11
- B sequential control 12
- Model uat150c 12
- Model uat180 240c model uat300c 12
- Caution 13
- English 13
- Operating range 13
- Phase protector 13
- Warning 13
- Air filter air filter 14
- Air filter position unit shown in the diagram is uat300c other models shall follow the same method 14
- For any enquiries on spare parts please contact your authorized dealer if any malfunction of the air conditioner unit is noted check the following fault conditions and causes for some simple troubleshooting tips 14
- If the fault persists please call your authorized local dealer serviceman 14
- Problem causes action 14
- Remove filter cover for filter service 14
- Service and maintenance 14
- Service parts maintenance procedures 14
- Troubleshooting 14
Похожие устройства
- Daikin UAT300CGXY1 Брошюра
- Daikin UAT300CGXY1 Руководство по эксплуатации
- Daikin UAT300CGXY1 Инструкция по монтажу
- Daikin UAT150CGXY19 Брошюра
- Daikin UAT150CGXY19 Руководство по эксплуатации
- Daikin UAT150CGXY19 Инструкция по монтажу
- Daikin UAT180CGXY19 Брошюра
- Daikin UAT180CGXY19 Руководство по эксплуатации
- Daikin UAT180CGXY19 Инструкция по монтажу
- Daikin UAT240CGXY19 Брошюра
- Daikin UAT240CGXY19 Руководство по эксплуатации
- Daikin UAT240CGXY19 Инструкция по монтажу
- Daikin UAT300CGXY19 Брошюра
- Daikin UAT300CGXY19 Руководство по эксплуатации
- Daikin UAT300CGXY19 Инструкция по монтажу
- Daikin UAT180AMY1 Инструкция по эксплуатации
- Daikin UAT180AMY1 Руководство по эксплуатации
- Daikin UAT180AMY1 Технические данные
- Daikin UAT180AMY1 Инструкция по монтажу
- Daikin UAT240AMY12 Инструкция по монтажу