Daikin UAT150CGXY19 [5/8] Anti corrosion protection as standard
![Daikin UAT240CGXY19 [5/8] Anti corrosion protection as standard](/views2/1694807/page5/bg5.png)
Anti corrosion protection as standard
Standard anticorrosion protection with the hydrophilic gold n coating, giving the condenser coil a longer life span under corrosive
environment.
Cooling only
Indoor UnIT UAT150CGXY UAT180CGXY UAT240CGXY UAT300CGXY
Cooling capacity Nom. kW
43.96 (1) / 42.26 (2) / 39.21 (3) / 38.71 (4) 56.36 (1) / 54.25 (2) / 50.85 (3) / 49.765 (4) 74.74 (1) / 71.81 (2) / 67.409 (3) / 64.478 (4) 92.12 (1) / 87.92 (2) / 83.47 (3) / 81.565 (4)
Btu/h
150,000 (1) / 144,200 (2) / 133,800 (3) / 132,100 (4) 192,300 (1) / 185,100 (2) / 173,500 (3) / 169,800 (4) 255,000 (1) / 245,000 (2), 230,000 (3) / 220,000 (4) 314,300 (1) / 300,000 (2) / 284,800 (3) / 278,300 (4)
Power input Cooling Nom. kW 13.07 16.92 23.00 28.36
EER W/W 1.51 (4) 1.55 (4) 1.62 (4) 1.57 (4)
Btu/hr/W
11,5 (1) / 11,0 (2) / 10,2 (3) / 10,1 (4) 11,4 (1) / 10,9 (2) / 10,4 (3) / 10,0 (4) 11,1 (1) / 10,7 (2) / 10,0 (3) / 9,6 (4) 11,1 (1) / 10,6 (2) / 10,0 (3) / 9,8 (4)
Evaporator Air ow rate Cooling m/min 130.38 184.08 223.74 246.06
cfm 276,262 390,047 474,083 521,377
External static pressure (standard) Pa 125 150 200 250
Casing Colour Light grey
Evaporator piping connections
Condensation drain size
OD mm 25.40
Condenser Dimensions Unit
HeightxWidthxDepth
mm 1,390x1,965x1,630
1,690x1,965x1,905 1,650x2,410x2,030
Weight Unit kg 600 650 850 980
Casing Colour Light grey
Material -
Operation range Cooling Min.~Max. °CDB 19~54
Sound pressure level
Nom. dBA 66 68 73
Sound power level
Nom. dBA 85 87 92
Refrigerant Type R-22
Power supply Phase/Frequency/Voltage Hz/V 3N~/50/380-415
(1) Gross cooling capacity based on 26.7 °C DB/19.4 °C WB indoor and 35 °C DB outdoor (2) Cooling capacity based on ARI standard with condition 26.7 °C DB/19.4 °C WB indoor and 35 °C DB outdoor (3) Gross cooling capacity based on 26.7 °C DB/19.4 °C WB
indoor and 46 °C DB outdoor (4) Gross cooling capacity based on 26.7 °C DB/19.4 °C WB indoor and 48 °C DB outdoor (5) Gross capacity does not include the eect of evaporator fan motor heat (6) All specications are subjected to change by the manufacturer
without prior notice. (7) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (8) All units are being tested and comply to ISO5151. (9) Sound pressure levels are according to JIS B 8615 standard. Position of the measurement is 1m in front
and 1m below the unit. (10) Designation based on cooling cycle.
Quiet operation as standard
The operating sound level is down to 66 dBA.
Easy duct design
Horizontal air discharge from the top and return air from the bottom for an easy duct design.
*** Mechanical control rooftop series name is UAT-CGXY9.
Rooftop unit Thermostat
Evaporator fan Dry contact input G (fan)
Comp 1 Dry contact input Y1 (Cooling 1)
Comp 2 Dry contact input Y2 (Cooling 2)
24 VAC 24 VAC
Flexible control: optional mechanical control series
For certain applications a mechanical control is required instead of PCB control. For the UAT-CGY series this is available through an optional
series***. The rooftop with mechanical control provides connection to the thermostat for control of evaporator fan motor, compressors
and condenser fan motor, and has a 24 Volt transformer provided for eld installed thermostat.
Separate service panel
Service panels are divided into two dierent sections for ease of servicing. Preliminary servicing & Troubleshooting can be conducted
by opening the top service panel, without stopping the unit operation.
Содержание
- Air conditioners 1
- Cooling only 1
- Uat cgxy remote control 1
- Features 2
- High efficiency 2
- Once the ductwork is installed the only thing left to do is 2
- Plug and play installation 2
- Auto random restart with last state memory 3
- Cdb 20 cdb 3
- Compact and light 3
- Control randomly instead of turning on at the same time 3
- Easy to control 3
- Flexibility of air supply 3
- In case of sudden power failure during operation unit will 3
- Indoor air quality 3
- Large line up 3
- Sequential lcd controller for uat cgxy and uat ay1 c10 c12 incorporates many functions like a 7 programmable timer 3
- The operation is based on the previous setting mode 3
- This ensures that air conditioners in the same building resume 3
- Wide operation range 3
- High efficiency range 4
- High performance under standard and high ambient conditions uat300cgy 4
- Independent refrigerant circuits 4
- Start up booster mode for quick cooling 4
- Uat cgxy 4
- And condenser fan motor and has a 24 volt transformer provided for field installed thermostat 5
- Anti corrosion protection as standard 5
- By opening the top service panel without stopping the unit operation 5
- Comp 1 dry contact input y1 cooling 1 5
- Comp 2 dry contact input y2 cooling 2 5
- Cooling only 5
- Easy duct design 5
- Environment 5
- Evaporator fan dry contact input g fan 5
- Flexible control optional mechanical control series 5
- For certain applications a mechanical control is required instead of pcb control for the uat cgy series this is available through an optional 5
- Horizontal air discharge from the top and return air from the bottom for an easy duct design 5
- Quiet operation as standard 5
- Rooftop unit thermostat 5
- Separate service panel 5
- Series the rooftop with mechanical control provides connection to the thermostat for control of evaporator fan motor compressors 5
- Service panels are divided into two different sections for ease of servicing preliminary servicing troubleshooting can be conducted 5
- Standard anticorrosion protection with the hydrophilic gold fin coating giving the condenser coil a longer life span under corrosive 5
- The operating sound level is down to 66 dba 5
- Vac 24 vac 5
- Standard efficiency range 6
- Uat ay1 6
- Available on uat320ay1 7
- Capacity is required 7
- Cooling only 7
- Field convertible return and supply air increases flexibility of installation 7
- High efficiency 7
- Horizontal throw 2 down throw 7
- Mode by simply repositioning the fan group 7
- Nominal eer up to 3 08 w w 10 5 btu hr w 7
- Partial loading 7
- Quiet operation as standard 7
- The 2 compressors systems can run at part load when less 7
- The operating sound level is down to 63 dba 7
- The return and discharge air flow can be shifted to vertical 7
- Daikin products are distributed by 8
- Ecpen13 135 8
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu be 0412 120 336 rpr oostende 8
- Remote control uat cgxy 8
Похожие устройства
- Daikin UAT150CGXY19 Руководство по эксплуатации
- Daikin UAT150CGXY19 Инструкция по монтажу
- Daikin UAT180CGXY19 Брошюра
- Daikin UAT180CGXY19 Руководство по эксплуатации
- Daikin UAT180CGXY19 Инструкция по монтажу
- Daikin UAT240CGXY19 Брошюра
- Daikin UAT240CGXY19 Руководство по эксплуатации
- Daikin UAT240CGXY19 Инструкция по монтажу
- Daikin UAT300CGXY19 Брошюра
- Daikin UAT300CGXY19 Руководство по эксплуатации
- Daikin UAT300CGXY19 Инструкция по монтажу
- Daikin UAT180AMY1 Инструкция по эксплуатации
- Daikin UAT180AMY1 Руководство по эксплуатации
- Daikin UAT180AMY1 Технические данные
- Daikin UAT180AMY1 Инструкция по монтажу
- Daikin UAT240AMY12 Инструкция по монтажу
- Daikin UAT240AMY12 Технические данные
- Daikin UAT240AMY12 Руководство по эксплуатации
- Daikin UAT240AMY12 Инструкция по эксплуатации
- Daikin UAT280AMY12 Технические данные