Daikin FRPJ280PYE [9/45] Cooling output

Daikin FRJ560PYE [9/45] Cooling output
7
INDICATED ANNUAL ENERGY CONSUMPTION
This fi gure indicates the approximate amount of energy consumed per year by the unit, based on a standard household
model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN
COOLING MODE AT FULL LOAD.
In order to calculate the cost of annual energy consumption, you merely multiply this fi gure by your electricity tariff.
COOLING OUTPUT
Cooling output is defi ned as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is
important to choose an air conditioning unit with a rated output suffi cient for your cooling/heating requirements. An
oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide
adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.
ENERGY EFFICIENCY RATIO (EER)
This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input).
In other words, the higher the EER, the greater the energy effi ciency.
TYPE
TYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating system
COOLING MODE: it indicates if the unit is air cooled or water cooled
HEATING OUTPUT
Heating output is defi ned as the heating capacity in kW of the appliance, operating in heating mode at full load.
ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE:
A EER 3.60
B 3.60 EER 3.40
C 3.40 EER 3.20
D 3.20 EER 2.80
E 2.80 EER 2.60
F 2.60 EER 2.40
G 2.40 EER
Noise level: only for portable units.
(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted
type) - for other units we refer to the multi brochure.