MEAN WELL HLN-60H-15B Datasheet онлайн

MEAN WELL HLN-60H-15B Datasheet онлайн
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION
Note.4
HLN-60H-15
A
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
COLD START 55A(twidth=265 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 40 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
338Khrs min. MIL-HDBK-217F (25 )
161*61.5*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
0.46Kg;32pcs/15.7Kg/1.10CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
Fully isolated plastic case with IP64 level
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp locations or outdoor application
3 years warranty
Features :
HLN-60H series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
A : IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
87%
88.5%
89%
89.5%
90%
90.5%90% 90.5%
±2.0%
2.4 ~ 4A
±1.0%
1.8 ~ 3A
±1.0%
1.5 ~ 2.5A
±1.0%
1.2 ~ 2A
±1.0%
1 ~ 1.7A
±1.0%
0.78 ~ 1.3A
±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
0.69 ~ 1.15A
±0.5%
±0.5%
±1.0%
0.87 ~ 1.45A
±0.5%
±0.5%
15V
HLN-60H-15 HLN-60H-36HLN-60H-24 HLN-60H-48HLN-60H-20 HLN-60H-42HLN-60H-30 HLN-60H-54
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
4A 3A 2.5A
2A
1.7A
1.3A
60W 60W 60W 60W
61.2W
62.4W
150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
300mVp-p
44 ~ 53V
54V
32.4 ~ 54V
1.15A
62.1W
300mVp-p
49 ~ 58V
42V
25.2 ~ 42V
1.45A
60.9W
300mVp-p
40 ~ 46V
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V 54 ~ 65V
48 ~ 58V 59 ~ 68V
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
EMC EMISSION
SELV
IP64
FMM
110
( except for 48V,54V )( for 48V,54V only)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
File Name:HLN-60H-SPEC 2014-08-14
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP64, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
500ms, 80ms at full load 230VAC / 115VAC