Daikin FXFQ32PVE [9/90] Fxfq63p 80pve

Daikin FXFQ25PVE [9/90] Fxfq63p 80pve
Dimensions ED39-865
8 FXFQ-P (R-410A)
FXFQ63P / 80PVE
(SQUARE-SHAPED TYPE)
C/L
(ROUND SHAPE TYPE)
(ROUND SHAPE TYPE)
A
B
C
B ARROW VIEW
C/L
4-M8~M10
300
OR LESS
(DIRECT INSTALLATION TYPE)
C/L
DRAIN CONNECTION SIDE
(NOTE 4)
(ROUND SHAPE TYPE)
FOR HEIGHT INSTALLATION
(K
N
O
C
K
H
O
LE
)
PIPE CONNECTION SIDE
(SQUARE-SHAPED TYPE)
(ROUND SHAPE TYPE)
A ARROW VIEW
C ARROW VIEW
(SQUARE-SHAPED TYPE)
(SQUARE-SHAPED TYPE)
60
246
55
20
860~910 (CELING OPENING SPACE) (NOTE 4)
35 OR LESS
110
20-M4 PREPARED HOLE
64
213
124
CONNECTION POSITION
OF BRANCH DUCT
160
256
CONNECTION POSITION
OF BRANCH DUCT
124
50
157
16-M4 PREPARED HOLE
CONNECTION POSITION
OF BRANCH DUCT
124
4
95
80
90
95
8
80
2 × 100=200
ADJUSTABLE (0~675)
850
340
80
90
350
840
420
256
780 (SUSPENTION POSITION)
157
157
95
81
81
840
130
150
175
CONNECTION POSITION
OF BRANCH DUCT
10
CONNECTION POSITION
OF FRESH AIR INTAKE KIT
160
124
CONNECTION POSITION
OF BRANCH DUCT
25
CONNECTION POSITION
OF BRANCH DUCT
109
NOTE 2
SUSPENTION BOLT
85
42
2 × 100=200
110
160
35 OR LESS (NOTE 4)
950
124
124
157
(REQUIRED SPACE)
1500 OR MORE
330
20-M4
PREPARED HOLE
FROM THE FLOOR SIDE 2500 OR MORE
1
6
2 × 100=200
9
350
950
350
125
55
2
710 (SUSPENTION POSITION)
860~910 (CELING OPENING SPACE) (NOTE 4)
280
φ 100
420
350
40
80
160
50
105
85
CONNECTION POSITION
OF BRANCH DUCT
110
5
CONNECTION POSITION
OF BRANCH DUCT
95
2 × 100=200
55
183
165
55
16-M4 HOLE
124
7
124
3
NOTE) 1. STICKING LOCATION FOR MANUFACTURE'S LABEL
MANUFACTURE'S LABEL FOR INDOOR UNIT:
SUCTION GRILL INNER SIDE'S ELECTRIC COMPONENTS BOX'S LID SURFACE
MANUFACTURE'S LABEL FOR DECORATION PANEL:
DECORATION PANEL'S CORNER DECORATION COVER INNER SURFACE
2. IN CASE OF USING WIRELESS REMOTE CONTROLLER, THIS POSITION WILL
BE A SIGNAL RECEIVER. REFER TO THE DRAWING OF WIRELESS REMOTE
CONTROLLER IN DETAIL.
3. WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30˚C AND
RH 80% OR THE FRESH AIR IS INDUCTED INTO THE CEILING OR THE UNIT
CONTINUES 24 HOUR OPERATION, AN ADDITIONAL INSULATION (THICKNESS
10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS REQUIRED.
4. THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 910mm
SQUARE CEILING OPENING, KEEP THE CLEARANCE OF 35mm OR LESS
BETWEEN THE INDOOR UNIT AND THE CEILING OPENING SO THAT THE
PANEL OVERLAP ALLOWANCE CAN BE ENSURED.
5. PLEASE DO NOT PLACE THE THING BEEN DAMP AND TROUBLED UNDER AN
INDOOR UNIT.
WHEN THE CASE WHERE HUMIDITY IS 80% OR MORE, AND THE DRAIN
OUTLET ARE CHOKED UP AND THE AIR FILTER ARE DIRTY, DEW MAY FALL.
• REQUIRED SPACE
1500mm OR MORE*
1500mm OR MORE*
1500mm OR MORE*
1500mm OR MORE*
200mm OR MORE*
200mm OR MORE*
* WHEN THE BLOW-OFF GRILL IS CLOSING. THE REQUIRED
SPACE IS 500mm OR MORE.
WHEN UNITING AND CLOSING A CORNER PART (BOTH
RIGHT AND LEFT OF THE BLOW-OFF GRILL TO CLOSE), IT
IS 200mm OR MORE.
• DECORATION PANEL
BYCP125K-W1 FRESH WHITE 6.5Y 9.5/0.5
ITEM PART NAME REMARK
SUCTION GRILLE
DRAIN HOSE (ACCESSORY)
DRAIN PIPE CONNECTION
CORNER DECORATION COVER
CONNECTION WIRING/
REMOTE CONTROL WIRING
CONNECTION
GAS PIPE CONNECTION
AIR-OUTLET
POWER-SOURCE WIRING
AND A UNIT WIRING CONNECTION
LIQUID PIPE CONNECTION
9
8
7
6
5
4
3
2
1
φ 15.9 (FLARE CONNECTION)
φ 9.5 (FLARE CONNECTION)
VP25 (OD φ 32)
LOCAL CONNECTION OD φ 32
(OUTLET) (UNIT CONNECTION
OD φ 26)
3D058460A