MEAN WELL HLP-60H-48 Datasheet онлайн

MEAN WELL HLP-60H-42 Datasheet онлайн
THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
CONSTANT CURRENT REGION Note.4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
COLD START 55A(twidth=265 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
288.5Khrs min. MIL-HDBK-217F (25)
147*53*27mm (L*W*H)






  
    




Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
0.2Kg;72pcs/15.4Kg/1.01CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output Switching Power Supply












HLP-60H series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
88%
89%
89.5%
90%
90%
90.5%
90%
90.5%
±2.0%
2.4 ~ 4A
±1.0%
1.8 ~ 3A
±1.0%
1.5 ~ 2.5A
±1.0%
1.2 ~ 2A
±1.0%
1 ~ 1.7A
±1.0%
0.78 ~ 1.3A
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±1.0%
0.69 ~ 1.15A
±0.5%
±0.5%
±1.0%
0.87 ~ 1.45A
±0.5%
±0.5%
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
4A
3A
2.5A
2A
1.7A
1.3A
60W
60W
60W
60W
61.2W
62.4W
150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
300mVp-p
44 ~ 53V
54V
32.4 ~ 54V
1.15A
62.1W
300mVp-p
49 ~ 58V
42V
25.2 ~ 42V
1.45A
60.9W
300mVp-p
40 ~ 46V
HLP-60H-15 HLP-60H-20 HLP-60H-24 HLP-60H-30 HLP-60H-36 HLP-60H-42 HLP-60H-48 HLP-60H-54
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
54 ~ 65V
48 ~ 58V
59 ~ 68V
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A, EAC TP TC 020
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
500ms, 80ms at full load 230VAC / 115VAC
File Name:HLP-60H-SPEC 2020-12-10
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C (60% load) ; EN61000-3-3, EAC TP TC 020
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13, , GB19510.14 GB19510.1,
EAC TP TC 004 EN60335-1 approved ; design refer to UL60950-1,

Bauar
Sicherh eit
egel gema
t gepru ft
od
be
www.
ID 2000000000
tuv.com
wac g
o s

Скачать