Daikin FXZQ32MVE [14/42] Main features
![Daikin FXZQ32MVE [14/42] Main features](/views2/1700118/page14/bge.png)
1
6
• Systems • Introduction
13
• Introduction
6Main features
6-2 Energy efficient solution
6-2-1 Low running costs
• VRV systems have low running costs because it permits each zone to be controlled individually. That is, only those rooms that require air conditioning
will be heated or cooled, while the system can be shut down completely in rooms where no air conditioning is required.
• VRV units have the highest COP/EER in the market in the most common operating area
6-2-2 Most advanced reluctance brushless DC compressor technology
The scroll compressor is driven by the newly developed motor, enabling better performance, higher enery efficiency resulting in higher energy cost
savings.
6-2-3 HRV - Heat Recovery Ventilation System
• Heat and humidity are exchanged between supply and exhaust air, which
-brings outdoor air close to indoor air conditions
-recovers energy loss
-realises considerable reduction of air conditioning capacity
• The VAM heat exchanger modulates the humidity and temperature of incoming fresh air to match indoor conditions.
• The balance achieved between indoor and outdoor ambients, enables the cooling/heating load placed on the air conditioning system to be reduced.
(heat and humidity are exchanged)
•Most energy saving solution as smaller indoor units can be selected:
- size down of indoor units down to 40 %
-payback total VAM system: ±2.5 years*
*conditions: outside cooling conditions: 30°C / outside heating conditions: - 8°C
inside cooling conditions: 24°C / inside heating conditions: 22°C
ventilation per room: 150m3/h
•Ideal modular concept to cope with the fresh air requirements
6-2-4 Auto restart capability
Even after exceptionally long power failures, the built-in auto restart capability ensures automatic system start up. Since the preset memory is not erased
by interruptions in power supply, no programme resetting is necessary.
First in the
industry
First in the
industry
Содержание
- I introduction table of contents 2
- Introduction 3
- Possible indoor units using r 410a 3
- Systems introduction 3
- 1 indoor unit capacity index 4
- Possible outdoor units using r 410a 4
- 1 indoor units 5
- Nomenclature 5
- 2 outdoor units 6
- Nomenclature 6
- Introduction 7
- Line up 7
- Systems introduction 7
- Technology 8
- Aero fitting grill aero spiral fan 9
- Dc fan motor 9
- E bridge circuit 9
- Technology 9
- Compact aero box 10
- E pass heat exchanger 10
- I demand function 10
- Technology 10
- 1 creating maximum comfort 11
- Main features 11
- 1 creating maximum comfort 12
- Main features 12
- 1 creating maximum comfort 13
- Main features 13
- 2 energy efficient solution 14
- Main features 14
- 2 energy efficient solution 15
- Main features 15
- 2 energy efficient solution 16
- Main features 16
- 3 high reliability 17
- Main features 17
- 3 high reliability 18
- Main features 18
- 4 eco friendly 19
- Main features 19
- 5 easy and flexible design 20
- Main features 20
- 5 easy and flexible design 21
- Main features 21
- 5 easy and flexible design 22
- Main features 22
- 6 simple and rapid installation 23
- Main features 23
- 6 simple and rapid installation 24
- Main features 24
- Main features 25
- Standard vrv system 25
- System 25
- 6 simple and rapid installation 26
- Main features 26
- 1 selection procedure system based on cooling load 27
- Selection procedure 27
- 1 selection procedure system based on cooling load 28
- Selection procedure 28
- 1 selection procedure system based on cooling load 29
- Selection procedure 29
- 2 capacity correction ratio 30
- Selection procedure 30
- 2 capacity correction ratio 31
- Selection procedure 31
- 2 capacity correction ratio 32
- Selection procedure 32
- 2 capacity correction ratio 33
- Selection procedure 33
- 2 capacity correction ratio 34
- Selection procedure 34
- 2 capacity correction ratio 35
- Selection procedure 35
- 2 capacity correction ratio 36
- Selection procedure 36
- 2 capacity correction ratio 37
- Selection procedure 37
- 3 refnet pipe system 38
- Selection procedure 38
- 3 refnet pipe system 39
- Selection procedure 39
- 4 refnet pipe selection 40
- Selection procedure 40
- Eede03 2 3 05 2003 prepared in belgium by vanmelle 42
- Specifications are subject to change without prior notice 42
- Systems 42
- Zandvoordestraat 300 b 8400 ostend belgium internet http www daikineurope com 42
Похожие устройства
- Daikin FXZQ32MVE Сервис мануал
- Daikin FXZQ40MVE Инструкция по эксплуатации
- Daikin FXZQ40MVE Инструкция по монтажу
- Daikin FXZQ40MVE Брошюра
- Daikin FXZQ40MVE Технические данные
- Haier C2F637CWRG Инструкция по эксплуатации
- Daikin FXZQ40MVE Сервис мануал
- Daikin FXZQ50MVE Инструкция по эксплуатации
- Daikin FXZQ50MVE Инструкция по монтажу
- Haier C2F536CMSRG Инструкция по эксплуатации
- Daikin FXZQ50MVE Брошюра
- Daikin FXZQ50MVE Технические данные
- Daikin FXZQ50MVE Сервис мануал
- Haier C2F536CWFG Инструкция по эксплуатации
- Haier C2F536MSFG Инструкция по эксплуатации
- Haier C2F537MSFG Инструкция по эксплуатации
- Haier C2F637CMG Инструкция по эксплуатации
- Haier A2F637CMG Инструкция по эксплуатации
- Haier C2F737CMG Инструкция по эксплуатации
- Haier A2F737CMG Инструкция по эксплуатации