MEAN WELL HVGC-240-1050AB [2/9] Hvgc 24

MEAN WELL HVGC-240-1050A [2/9] Hvgc 24
SPECIFICATION
240W Constant Current Mode LED Driver
HVGC-240 series
File Name:HVGC-240-SPEC 2018-10-18
MODEL
RATED CURRENT
RATED POWER
OPEN CIRCUIT VOLTAGE (max.)
OUTPUT
CURRENT ADJ. RANGE
SET UP TIME
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A/AB-Type only (via built-in potentiometer)
47 ~ 63Hz
0.76A / 347VAC 0.56A / 480VAC
<0.75mA / 480VAC
Compliance to FCC Part 15 Subpart B, EN55015, EN61000-3-2(@load 80%), EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level surge immunity Line-Earth 4KV, Line-Line 2KV , EAC TP TC 020()
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃
0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 (type”HL”), CSA C22.2 No. 250.13-12, IEC/EN61347-1,IEC/EN61347-2-13, EN62384 independent,
EAC TP TC 004 IP65 or IP67 approved,
143.6K hrs min. MIL-HDBK-217F (25 )
254.2*68*38.8mm (L*W*H)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
240 ~ 263V360 ~ 394V
120 ~ 131.4V
180 ~ 197V
144 ~ 158V
90 ~ 99V 72 ~ 79V
93.5%
93%
92.5%93% 93% 92.5% 92.5%
350~700mA 525~1050mA 700~1400mA
875~1750mA
1050~2100mA
1400~2800mA
1750~3500mA
700mA
171.4 ~ 342.8V
1050mA
114.3 ~ 228.6V
2100mA
57.2 ~ 114.3V
240W
354V
240W
235V
240W
176V
240W
141V
240W
117V
240W
88V
240.1W
71V
2800mA 3500mA
42.9 ~ 85.7V
34.3 ~ 68.6V
1400mA 1750mA
85.7 ~ 171.4V
68.5~137.1V
EMC IMMUNITY
EMC EMISSION
COLD START 50A(t = 532 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION
Note.2
PACKING
1.35Kg; 12pcs/17.2Kg/0.78CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 347VAC input, rated current and 25 of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by thedriver
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.
7. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
9. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
μ
500ms/230VAC, 347VAC, 480VAC
Shut down and latch off o/p voltage, re-power on to recover
Shut down o/p voltage with re-power on to recovery
HVGC-240-700
HVGC-240-1050
HVGC-240-1400
HVGC-240-1750
HVGC-240-2100
HVGC-240-2800
HVGC-240-3500
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC
CURRENT RIPPLE 5.0% max. @rated current
CURRENT TOLERANCE ±
5%
VOLTAGE RANGE
Note.3
180 ~ 528VAC 254VDC ~ 747VDC
(Please refer to "STATIC CHARACTERISTIC" section)
POWER FACTOR (Typ.)
PF 0.9 /230VAC, PF 0.9 /277VAC full load≧≧≧≧8 7 , PF 0.95/347VAC, PF 0.93/480VAC @
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20%(@ load 50%/230VAC, 277VAC, 347VAC, @ load 60%/480VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
WORKING TEMP.
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase=+90