MEAN WELL LPF-40D-48 [2/8] Lpf 40d

MEAN WELL LPF-40D-42 [2/8] Lpf 40d
LPF-40D series
SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
47 ~ 63Hz
<0.75mA / 240VAC
Compliance to
EN55015
,EN61000-3-2 Class C (@load60%) ; EN61000-3-3
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
1144.7K hrs min. Telcordia SR-332 (Bellcore) ; 394.9Khrs min. MIL-HDBK-217F (25)
ENVIRONMENT
EMC EMISSION Note.8
SAFETY &
EMC
PROTECTION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
TOTAL HARMONIC DISTORTION
DC VOLTAGE
RATED CURRENT
RATED POWER Note.5
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
CONSTANT CURRENT REGION Note.2
OVER CURRENT
SAFETY STANDARDS Note.8
COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACμ ; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
MAX. CASE TEMP.
Tcase=+80
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV)
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 305VAC 127 ~ 431VDC
1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25ofambienttemperature.
2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".
3.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.
4.Tolerance:includessetuptolerance,lineregulationandloadregulation.
5.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.
6.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthedrivermayleadtoincreaseofthesetuptime.
7.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe
completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.
8.ThemodelcertifiedforCCC(GB19510.14,GB19510.1,GB17743andGB17625.1)isanoptionalmodel.PleasecontactMEANWELLfordetails.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch
without permanently connected to the mains.
10.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTcase,particularlytcpoint(orTMP,perDLC),isabout75orless.
11.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load60%/115VC,230VAC; @load75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
Tcase=-40 ~ +80 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Shut down o/p voltage, re-power on to recover
16ms/230VAC 16ms/115VAC
1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC
Shut down o/p voltage, re-power on to recover
40W Constant Current Mode LED Driver
CURRENT TOLERANCE
CURRENT RIPPLE
±5.0%
5.0% max. @rated current
LPF-40D-12
LPF-40D-15
LPF-40D-20
LPF-40D-24
LPF-40D-30
LPF-40D-36
LPF-40D-42
LPF-40D-48
LPF-40D-54
12V 15V 20V 24V 30V
36V
48V 54V
42V
15 ~ 17V 17.5 ~ 21V
23 ~ 27V
28 ~ 35V
34 ~ 40V
41 ~ 49V 54 ~ 63V
46 ~ 54V 59 ~ 66V
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP67,
J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
162.5*43*32mm (L*W*H)
0.45Kg; 32pcs/15.4Kg/0.93CUFT
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
3.34A 2.67A 2A 1.67A
1.34A
1.12A
0.84A 0.76A
0.96A
40.08W 40.08W 40W 40.08W 40.2W
40.32W
40.32W 41.04W
40.32W
7.2 ~12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
28.8 ~ 48V 32.4 ~ 54V
25.2 ~ 42V
84%
85%
86%
87%
88%
88%
89%88.5% 89%
0.6A / 115VAC 0.3A / 230VAC 0.25A/277VAC
File Name:LPF-40D-SPEC 2017-04-13
Скачать