Daikin FXMQ40PVE [11/20] Dimensional drawing centre of gravity
![Daikin FXMQ32PVE [11/20] Dimensional drawing centre of gravity](/views2/1702321/page11/bgb.png)
• Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE
•VRV
®
Systems • Indoor Units
140
6 Dimensional drawing & centre of gravity
6 - 1 Dimensional drawing
FXMQ40P
3D060160
12 Drain hose (accessory) O.D. ø 32 (outlet)
11 Socket (for maintenance)
VP25 (O.D. ø 32 /I.D. ø 25)
10 Hook For M10
9 Air suction flange
8 Air discharge flange
7 Power supply connection
6 Interunit wiring connection
5 Control box (inside)
4 Ground terminal (in control box) M4
3 Drain pipe connection
VP25 (O.D. ø 32 /I.D. ø 25)
2 Gas pipe connection ø 12.7 flale connection
1 Liquid pipe connection ø 6.4 flale connection
ITEM
PART NAME REMARK
20-ø 4.7 hole
(All around)
(Suspention bolt position)
Air Outlet
26-ø 4.7 hole
(All around)
or less
Air Inlet
12 - 8x12 oblong hole
(All around)
450 or more
(service space)
700 or more
(service space)
View
(From the Air Outlet)
Inspection hatch 450 or more
700 or more
Adjustable
(467 or less)
Air outlet
Ceiling
Floor surface
300 or more
Air Inlet
(Note 2)
(Note 4)
(A case without the
ceiling)
14 - 8x12 oblong hole
(All around)
(From the air inlet)
300 or less
Fig. A
View B-1
View B-2
Inspection hatch 2
Air
outlet
Air
inlet
Control box
<Inspection hatch>
(Ceiling opening)
Control box
Inspection hatch
Ceiling
Inspection hatch
Ceiling
Inspection hatch (450mmx450mm)
Inspection hatch (°450)
Control box
Control box
Control box
Inspection hatch 3
or more
or lessor more
or more
NOTES
1 Location of MANUFACTURE’S LABEL: Control box
surface
2 Mount the air filter at the suction side.
(Select its colorimethod (gravity method) 50% or more)
3 Do not locate things should not be wet under the indoor
unit.
Dews may droop when humidity reaches over 80%, or a
drain gets stuck, or air filters are not clean.
4 Space for Service Works
1) One inspection hatch (450x450) on the control box side and a space of 300mm or
more under the unit. (Fig.A)
2) One inspection hatch (450x450) on the control box side and 2 (two) inspection
hatches under the unit (Arrow view B-1)
3) 3 (three) inspection hatches under the unit and the control box. (Arrow view B-2)
According to any one of below 1) - 3), secure a space for service works, such
as, checking and maintenance of control box and drain pumps, etc.
FXMQ50,63,80P
3D060161
12 Drain hose (accessory) O.D. ø 32 (outlet)
11 Socket (for maintenance)
VP25 (O.D. ø 32 /I.D. ø 25)
10 Hook For M10
9 Air suction flange
8 Air discharge flange
7 Power supply connection
6 Interunit wiring connection
5 Control box (inside)
4 Ground terminal (in control box) M4
3 Drain pipe connection
VP25 (O.D. ø 32 /I.D. ø 25)
2 Gas pipe connection ø 15.9 flale connection
1 Liquid pipe connection ø 9.5 flale connection
ITEM
PART NAME REMARK
30-ø 4.7 hole
(All around)
(Suspention bolt position)
Air Outlet
36-ø 4.7 hole
(All around)
or less
Air Inlet
16 - 8x12 oblong hole
(All around)
450 or more
(service space)
700 or more
(service space)
View
(From the Air Outlet)
Inspection hatch 450 or more
700 or Less
Adjustable
(467 or more)
Air outlet
Ceiling
Floor surface
300 or more
Air Inlet
(Note 2)
(Note 4)
2500 or more
(A case without the
ceiling)
18 - 8x12 oblong hole
(All around)
(From the air inlet)
300 or less
Fig. A
View B-1
View B-2
Inspection hatch 2
Air
outlet
Air
inlet
Control box
<Inspection hatch>
(Ceiling opening)
Control box
Inspection hatch
Ceiling
Inspection hatch
Ceiling
Inspection hatch (450mmx450mm)
Inspection hatch (°450)
Control box
Control box
Control box
Inspection hatch 3
or more
or lessor more
or more
NOTES
1 Location of MANUFACTURE’S LABEL: Control box
surface
2 Mount the air filter at the suction side.
(Select its colorimethod (gravity method) 50% or
more)
3 Do not locate things should not be wet under the
indoor unit.
Dews may droop when humidity reaches over 80%,
or a drain gets stuck, or air filters are not clean.
4 Space for Service Works
According to any one of below 1) - 3), secure a space for service works, such
as, checking and maintenance of control box and drain pumps, etc.
1) One inspection hatch (450x450) on the control box side and a space of
300mm or more under the unit. (Fig.A)
2) One inspection hatch (450x450) on the control box side and 2 (two)
inspection hatches under the unit (Arrow view B-1)
3)
3 (three) inspection hatches under the unit and the control box. (Arrow view B-2)
Содержание
- Air conditioning systems 1
- Technical data 1
- Capacity table 2
- Centre of gravity 2
- Control system 2
- Cooling capacity tables 2
- Dimensional drawing 2
- Dimensional drawing centre of gravit 2
- Electrical specifications 2
- Fan characteristic 2
- Heating capacity tables 2
- Option 2
- Piping diagra 2
- Safety device setting 2
- Sound dat 2
- Sound pressure spectrum 2
- Specification 2
- Table of contents fxmq pve 2
- Technical specifications 2
- Wiring diagra 2
- Wiring diagram 2
- 1 technical specifications 3
- Indoor units concealed ceiling unit fxmq pve 3
- Specifications 3
- Systems indoor units 132 3
- 2 electrical specifications 4
- Indoor units concealed ceiling unit fxmq pve 4
- Specifications 4
- Systems indoor units 133 4
- D034597e 5
- D060443 5
- Fxmq p 5
- Indoor units concealed ceiling unit fxmq pve 5
- Options 5
- Safety device settings 5
- See the latest for the modification marks 5
- Systems indoor units 134 5
- Control systems 6
- D060455 6
- Fxmq p 6
- 1 cooling capacity tables 7
- Capacity tables 7
- Fxmq p 7
- Indoor units concealed ceiling unit fxmq pve 7
- Systems indoor units 136 7
- 1 cooling capacity tables 8
- Capacity tables 8
- Fxmq p 8
- Indoor units concealed ceiling unit fxmq pve 8
- Systems indoor units 137 8
- 2 heating capacity tables 9
- Capacity tables 9
- Fxmq p 9
- Indoor units concealed ceiling unit fxmq pve 9
- Systems indoor units 138 9
- 2 heating capacity tables 10
- Capacity tables 10
- Fxmq p 10
- Indoor units concealed ceiling unit fxmq pve 10
- Systems indoor units 139 10
- 1 dimensional drawing 11
- 8x12 oblong hole 11
- 8x12 oblong hole all around 11
- According to any one of below 1 3 secure a space for service works such as checking and maintenance of control box and drain pumps etc 11
- Air inlet 11
- Air inlet note 2 11
- Air outlet 11
- Air outlet air inlet 11
- All around 11
- All around suspention bolt position 11
- Ceiling floor surface 11
- Ceiling opening 11
- Control box 11
- Control box control box 11
- Control box inspection hatch 3 11
- D060160 11
- Dimensional drawing centre of gravity 11
- Drain hose accessory o d ø 32 outlet 11 socket for maintenance 11
- From the air inlet 11
- From the air outlet 11
- Fxmq40p 11
- Gas pipe connection ø 12 flale connection 1 liquid pipe connection ø 6 flale connection 11
- Gas pipe connection ø 15 flale connection 1 liquid pipe connection ø 9 flale connection 11
- Hook for m10 9 air suction flange 8 air discharge flange 7 power supply connection 6 interunit wiring connection 5 control box inside 4 ground terminal in control box m4 3 drain pipe connection 11
- Indoor units concealed ceiling unit fxmq pve 11
- Inspection hatch 450 or more 11
- Inspection hatch 450mmx450mm inspection hatch 450 11
- Inspection hatch ceiling 11
- Location of manufacture s label control box surface 2 mount the air filter at the suction side select its colorimethod gravity method 50 or more 3 do not locate things should not be wet under the indoor unit dews may droop when humidity reaches over 80 or a drain gets stuck or air filters are not clean 11
- One inspection hatch 450x450 on the control box side and a space of 300mm or more under the unit fig a 2 one inspection hatch 450x450 on the control box side and 2 two inspection hatches under the unit arrow view b 1 3 11
- One inspection hatch 450x450 on the control box side and a space of 300mm or more under the unit fig a 2 one inspection hatch 450x450 on the control box side and 2 two inspection hatches under the unit arrow view b 1 3 3 three inspection hatches under the unit and the control box arrow view b 2 11
- Or less 11
- Or more 11
- Part name remark 11
- Service space 11
- Systems indoor units 140 11
- Three inspection hatches under the unit and the control box arrow view b 2 11
- View b 1 view b 2 inspection hatch 2 11
- Vp25 o d ø 32 i d ø 25 11
- Ø 4 hole 11
- 1 dimensional drawing 12
- Between remote control and control box 12
- Conduit 12
- Control box 12
- Cord oulet hole 12
- Dimensional drawing centre of gravity 12
- Exposed body embedded cord exposed body embedded code 12
- Exposed body exposed cord 12
- For australia for other countries 12
- Indoor units concealed ceiling unit fxmq pve 12
- Installation method 12
- Location of manufacture s label control box surface 2 mount the air filter at the suction side select its colorimethod gravity method 50 or more 3 do not locate things should not be wet under the indoor unit dews may droop when humidity reaches over 80 or a drain gets stuck or air filters are not clean 12
- Remote control 12
- Remote control dimensions 12
- Shield wire insulated thickness 1mm or more vinyl cord with sheath or cable insulated thickness 1mm or more 12
- Staple 12
- Systems indoor units 141 12
- Through hole 12
- 1 dimensional drawing 13
- 5x9 slot 13
- Ceiling opening 13
- Dimensional drawing centre of gravity 13
- Indoor units concealed ceiling unit fxmq pve 13
- Liquid crystal remote control wireless 13
- Location of manufacture s label control box surface 2 mount the air filter at the suction side select its colorimethod gravity method 50 or more 3 do not locate things should not be wet under the indoor unit dews may droop when humidity reaches over 80 or a drain gets stuck or air filters are not clean 13
- Remote control dimensions receiver detail 13
- Remote control holder 13
- Remote control holder installation procedure installation to wall surface 13
- Service space for ceiling installation 13
- Switch box 13
- Systems indoor units 142 13
- Transmitting part 13
- 2 centre of gravity 14
- Dimensional drawing centre of gravity 14
- Fxmq100 125p 14
- Fxmq40p 14
- Fxmq50 63 80p 14
- Model name 14
- D034245c 15
- Fxmq p 15
- Indoor units concealed ceiling unit fxmq pve 15
- Piping diagram 15
- Systems indoor units 144 15
- 1 wiring diagram 16
- Indoor units concealed ceiling unit fxmq pve 16
- Systems indoor units 145 16
- Wiring diagram 16
- 1 sound pressure spectrum 17
- D060428 17
- D060429 17
- D060446 17
- D060447 17
- Fxmq40p 17
- Fxmq50p 17
- Fxmq63p 17
- Fxmq80p 17
- Indoor units concealed ceiling unit fxmq pve 17
- Sound data 17
- Systems indoor units 146 17
- 1 sound pressure spectrum 18
- D060448 18
- D060449 18
- Fxmq100p 18
- Fxmq125p 18
- Indoor units concealed ceiling unit fxmq pve 18
- Sound data 18
- Systems indoor units 147 18
- D060456 19
- D060457 19
- D060458 19
- D060459 19
- D060460 19
- D060461 19
- External static pressure 19
- Fan characteristics 19
- Fxmq100p 19
- Fxmq125p 19
- Fxmq40p 19
- Fxmq50p 19
- Fxmq63p 19
- Fxmq80p 19
- Indoor units concealed ceiling unit fxmq pve 19
- Systems indoor units 148 19
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu btw be 0412 120 336 rpr oostende 20
- Èeeden08 204aëí 20
Похожие устройства
- Daikin FXMQ50PVE Инструкция по эксплуатации
- Daikin FXMQ50PVE Инструкция по монтажу
- Daikin FXMQ50PVE Технические данные
- Daikin FXMQ63PVE Инструкция по эксплуатации
- Daikin FXMQ63PVE Инструкция по монтажу
- Daikin FXMQ63PVE Технические данные
- Daikin FXMQ80PVE Инструкция по эксплуатации
- Daikin FXMQ80PVE Инструкция по монтажу
- Daikin FXMQ80PVE Технические данные
- Daikin FXMQ100PVE Инструкция по эксплуатации
- Daikin FXMQ100PVE Инструкция по монтажу
- Daikin FXMQ100PVE Технические данные
- Daikin FXMQ125PVE Инструкция по эксплуатации
- Daikin FXMQ125PVE Инструкция по монтажу
- Daikin FXMQ125PVE Технические данные
- Daikin FXMQ140PVE Инструкция по эксплуатации
- Daikin FXMQ140PVE Инструкция по монтажу
- Daikin FXMQ140PVE Технические данные
- Daikin FXMQ20PVE4 Инструкция по эксплуатации
- Daikin FXMQ20PVE4 Инструкция по монтажу