Daikin FXDQ25PBNVT [77/458] Ceiling mounted duct type

Daikin RXYQ8P9W1B [77/458] Ceiling mounted duct type
Specifications Si34-803
66 Specifications
Ceiling Mounted Duct Type
Note:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level
difference : 0 m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level
difference : 0 m.
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5 m, level difference :
0 m.
4 External static pressure is changeable in 13 or 14 stages within the ( ) range by remote controller.
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its
colorimetric method (gravity method) 50% or more.
6 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
7 Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During
actual operation, these values are normally somewhat higher as a result of ambient conditions.
Model FXMQ100PVE FXMQ125PVE
1 Cooling Capacity (19.5°CWB)
kcal/h 10,000 12,500
Btu/h 39,600 49,500
kW 11.6 14.5
2 Cooling Capacity (19.0°CWB) kW 11.2 14.0
3 Heating Capacity
kcal/h 10,800 13,800
Btu/h 42,700 54,600
kW 12.5 16.0
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions: (H×W×D) mm 300×1,400×700 300×1,400×700
Coil (Cross
Fin Coil)
Rows×Stages×Fin Pitch mm 3×16×1.75 3×16×1.75
Face Area 0.383 0.383
Fan
Model
Type Sirocco Fan Sirocco Fan
Motor Output × Number
of Units
W 350×1 350×1
Air Flow Rate (HH/H/L)
m³/min 32/27/23 39/33/28
cfm 1,130/953/812 1,377/1,165/988
External Static
Pressure
Pa Standard 100 (200-50 4) Standard 100 (200-50 4)
Drive Direct Drive Direct Drive
Temperature Control Microprocessor Thermostat for Cooling and Heating Microprocessor Thermostat for Cooling and Heating
Air Filter 5 5
Piping
Connections
Liquid Pipes mm φ9.5 (Flare Connection) φ9.5 (Flare Connection)
Gas Pipes mm φ15.9 (Flare Connection) φ15.9 (Flare Connection)
Drain Pipe mm
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
Mass (Weight) kg 46 46
7 Sound Level (HH/H/L) dBA
220V 43/41/39 44/42/40
240V 43/41/39 44/42/40
Safety Devices
Fuse.
Fan Driver Overload Protector.
Fuse.
Fan Driver Overload Protector.
Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve
Connectable Outdoor Unit R-410A P(A) Series R-410A P(A) Series
Standard Accessories
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
Drawing No. C : 3D060388A
() ()
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3