MEAN WELL PLN-100-24 Datasheet онлайн

MHZ MEAN WELL P L N 1 00 series 100W Single Output Switching Power Supply Features Universal AC input Full range Protections Short circuit Overload Over voltage Over temperature Built in active PFC function IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100 full load burn in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty V V W LPS MODEL PLN 100 15 PLN 100 20 PLN 100 24 PLN 100 27 PLN 100 36 PLN 100 48 12V 15V 20V 24V 27V 36V 48V LED OPERATION VOLTAGE Note 7 6 12V 7 5 15V 10 20V 12 24V 13 5 27V 18 36V 24 48V RATED CURRENT 5A 5A 4 8A 4A 3 55A 2 65A 2A 0 5A 0 5A 0 4 8A 0 4A 0 3 55A 0 2 65A 0 2A 60W 75W 96W 96W 95 85W 95 4W 96W RIPPLE NOISE max Note 2 150mVp p 150mVp p 150mVp p 150mVp p 150mVp p 150mVp p 200mVp p VOLTAGE ADJ RANGE 0 15 Can be adjusted by internal potential meter SVR1 3 0 2 0 2 0 87 87 Note 6 CURRENT RANGE Note 6 RATED POWER INPUT Ell C PLN 100 12 DC VOLTAGE OUTPUT IP64 Note 6 CURRENT ADJ RANGE 3 25 Can be adjusted by internal potential meter SVR2 VOLTAGE TOLERANCE Note 3 3 0 LINE REGULATION 1 0 LOAD REGULATION 2 0 3 0 3 0 3 0 SETUP RISE TIME 1200ms 80ms 230VAC 1200ms 80ms 115VAC at full load HOLD UP TIME Typ 60ms 230VAC 30ms 115VAC at full load VOLTAGE RANGE Note 5 90 264VAC FREQUENCY RANGE 47 63Hz POWER FACTOR Typ PF 0 95 230VAC EFFICIENCY Typ 83 AC CURRENT Typ 12V 0 8A 115VAC 0 4A 230VAC INRUSH CURRENT Typ COLD START 40A 230VAC 87 87 87 15V 0 9A 115VAC 0 45A 230VAC 20V 48V 1 1A 115VAC 0 55A 230VAC 0 5mA 240VAC LEAKAGE CURRENT OVER CURRENT PF 0 98 115VAC at full load 85 Note 4 95 100 Protection type Constant current limiting recovers automatically after fault condition is removed 13 16V PROTECTION OVERVOLTAGE 16 5 20 V 22 27V 27 34V 29 36V 39 48V 52 64V Protection type Shut down and latch off o p voltage re power on to recover 90r 10r RTH2 OVER TEMPERATURE ENVIRONMENT Protection type Shut down o p voltage re power on to recover WORKING TEMP 30 50 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing STORAGE TEMP HUMIDITY 40 80 C 10 95 RH TEMP COEFFICIENT 0 03 C 0 50 C VIBRATION 10 500Hz 2G 10min 1 cycle period for 60min each along X Y Z axes SAFETY STANDARDS UL1310 Class 2 TUV EN60950 1 EN61347 1 EN61347 2 13 CAN CSAC22 2 No 223 M91 except for 48V IP64 approved WITHSTAND VOLTAGE l P O P 4 25KVDC SAFETY ISOLATION RESISTANCE I P O P100M Ohms 500VDC EMC EMI CONDUCTION RADIATION Compliance to EN55015 EN55022 CISPR22 Class B HARMONIC CURRENT Compliance to EN61000 3 2 3 OTHERS EMS IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN61547 EN55024 light industry level criteria A MTBF 303 1Khrs min MIL HDBK 217F 25 0 DIMENSION 200 70 5 35mm L W H PACKING 0 52Kg 20pcs 11 4Kg 0 76CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature 2 Ripple noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1 uf 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 Please refer to OLP characteristics 5 Derating may be needed under low input voltage Please check the derating curve for more details 6 This is the maximum possible output current and power Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2 7 Constant current operation region is within 50 100 rated output voltage This is the suitable operation region for LED related applications File Name PLN 100 SPEC 2007 12 24

Скачать