MEAN WELL PLN-30-15 Datasheet онлайн

MW I MEAN WELL PLN 30 series 30W Single Output Switching Power Supply Features Universal AC input Full range Fully isolated plastic case with IP64 level Built in constant current limiting circuit with adjustable OCP level Protections Short circuit Over load Over voltage Over temperature Built in active PFC function IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100 full load burn in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty FV V 10 м м SELV ipe V V E ul О exceptror 4ev 1ГО4 41FgZ a c MODEL DC VOLTAGE OUTPUT us Ivv IP64 CF САИ C PLN 30 9 PLN 30 12 PLN 30 15 PLN 30 20 PLN 30 24 PLN 30 27 PLN 30 36 PLN 30 48 9V 12V 15V 20V 24V 27V 36V 48V LED OPERATION VOLTAGE Note 6 6 3 9V 8 4 12V 10 5 15V 14 20V 16 8 24V 18 9 27V 25 2 36V 33 6 48V RATED CURRENT 3 3A 2 5A 2A 1 5A 1 25A 1 12A 0 84A 0 63A CURRENT RANGE 0 3 ЗА 0 2 5A 0 2A 0 1 5A 0 1 25A 0 1 12A 0 0 84A 0 0 63A RATED POWER 29 7W 30W 30W 30W 30W 30 24W 30 24W 30 24W 2Vp p 2 6Vp p 2Vp p 2 6Vp p 2 3Vp p 4 5Vp p 3 7Vp p 85 85 86 86 40 50V 53 63V RIPPLE NOISE max Note 22 6Vp p VOLTAGE ADJ RANGE Note 5 10 Can be adjusted by internal potential meter SVR1 CURRENT ADJ RANGE Note 53 25 Can be adjusted by internal potential meter SVR2 VOLTAGE TOLERANCE Note 3 10 INPUT LINE REGULATION 3 0 LOAD REGULATION 10 SETUP RISE TIME 1500ms 150ms 230VAC 3000ms 150ms 115VAC at full load VOLTAGE RANGE 90 264VAC FREQUENCY RANGE 47 63Hz POWER FACTOR PF 0 9 230VAC EFFICIENCY Typ 80 AC CURRENT 0 4A 115VAC 0 2A 230VAC INRUSH CURRENT max 40A 230VAC LEAKAGE CURRENT 0 5mA 240VAC OVER CURRENT Note 4 PF 0 95 115VAC at full load 83 84 84 110 120 Protection type Constant current limiting recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION OVER VOLTAGE Hiccup mode recovers automatically after fault condition is removed 10 14V 14 16V 17 22V 23 26V 27 34V 31 35V Protection type Shut down o p voltage re power on to recover 90C 10C TSW1 OVER TEMPERATURE ENVIRONMENT Protection type Shut down o p voltage re power on to recover WORKING TEMP 30 50 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing STORAGE TEMP HUMIDITY 40 80 C 10 95 RH TEMP COEFFICIENT 0 06 C 0 50C VIBRATION 10 500Hz 2G 10min 1 cycle period for 60min each along X Y Z axes SAFETY STANDARDS UL1310 Class 2 TUV EN61347 1 EN61347 2 13 CAN CSAC22 2 No 223 M91 except for 48V IP64 approved Compliance to EN55015 EMI CONDUCTION RADIATION SAFETY HARMONIC CURRENT Compliance to EN61000 3 2 3 EMC EMS IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 EN61547 light industry level criteria A WITHSTAND VOLTAGE l P O P 3KVAC OTHERS ISOLATION RESISTANCE l P O P 100M Ohms 500VDC 25 C 70 RH MTBF 621 4Khrs min MIL HDBK 217F 250 DIMENSION 145 47 30mm L W H PACKING 0 22Kg 60pcs 14 2Kg 1 25CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature 2 Ripple noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1 uf 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 Please refer to OLP characteristics 5 Output voltage can be adjusted through the SVR1 on the PCB limit of output constant current level can be adjusted through the SVR2 on the PCB 6 Constant current operation region is within 70 100 rated output voltage This is the suitable operation region for LED related applications File Name PLN 30 SPEC 2008 02 05

Скачать