MEAN WELL PLN-60-15 Datasheet онлайн

411V MEAN WELL PLN 60 series 60W Single Output Switching Power Supply Features Universal AC input Full range Fully isolated plastic case with IP64 level Built in constant current limiting circuit with adjustable OCP level Protections Short circuit Overload Over voltage Over temperature Built in active PFC function IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100 full load burn in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty V W V LPS MODEL DC VOLTAGE OUTPUT IP64 EH C PLN 60 12 PLN 60 15 PLN 60 20 PLN 60 24 PLN 60 27 PLN 60 36 PLN 60 48 12V 15V 20V 24V 27V 36V 48V 33 6 48V LED OPERATION VOLTAGE Nole 7 8 4 12V 10 5 15V 14 20V 16 8 24V 18 9 27V 25 2 36V RATED CURRENT 5A 4A 3A 2 5A 2 3A 1 7A 1 3A CURRENT RANGE 0 5A 0 4A 0 3A 0 2 5A 0 2 3A 0 1 7A 0 1 3A RATED POWER 60W 60W 60W 60W 62 1W 61W 62 5W 2 4Vp p 1 8Vp p 2 7Vp p 2 7Vp p 3 6Vp p 4 6Vp p 22 26V 25 30V 32 5 39V 43 6 51 8V 87 87 88 RIPPLE NOISE max Note 22Vp p 11 13V 13 8 16 2V 18 22V VOLTAGE ADJ RANGE Note 6 Can be adjusted by internal potential meter SVR1 CURRENT ADJ RANGE Note 63 25 Can be adjusted by internal potential meter SVR2 VOLTAGE TOLERANCE Note 3 10 INPUT LINE REGULATION 4 0 LOAD REGULATION 10 SETUP RISE TIME 1500ms 100ms 230VAC 3000ms 100ms 115VAC at full load VOLTAGE RANGE Note 5 90 264VAC FREQUENCY RANGE 47 63Hz POWER FACTOR PF 0 9 230VAC EFFICIENCY Typ 83 AC CURRENT 0 8A 115VAC 0 4A 230VAC INRUSH CURRENT max 40A 230VAC LEAKAGE CURRENT PF 0 98 115VAC at full load 84 5 86 5 86 5 0 5mA 240VAC 95 110 OVER CURRENT 130 max Protection type Constant current limiting recovers automatically after fault condition is removed SHORT CIRCUIT Note 4 Hiccup mode recovers automatically after fault condition is removed 13 8 16V PROTECTION OVERVOLTAGE 17 5 21V 22 8 25V 28 32V 31 35V 41 46V 54 60V Protection type Shut down o p voltage re power on to recover 95 C 10 C TSW1 detecton heatsink of power transistor OVER TEMPERATURE ENVIRONMENT 30 50 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing STORAGE TEMP HUMIDITY 40 80f 10 95 RH TEMP COEFFICIENT 10 500Hz 2G 10min 1 cycle period for 60min each along X Y Zaxes SAFETY STANDARDS UL1310 Class 2 TUV EN61347 1 EN61347 2 13 CAN CSAC22 2 No 223 M91 except for 48V IP64 approved WITHSTAND VOLTAGE l P O P 4 25KVDC l P 0 P 100MChms 500VDC Compliance to EN55015 EN55022 CISPR22 Class B EMI CONDUCTION RADIATION HARMONIC CURRENT OTHERS 0 03 C 0 50 C VIBRATION SAFETY ISOLATION RESISTANCE EMC Protection type Shut down o p voltage recovers automatically after temperature goes down WORKING TEMP Compliance to EN61000 3 2 3 EMS IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 EN61547 light industry level criteria A MTBF 497 8Khrs min MIL HDBK 217F 25t DIMENSION 181 61 5 35mm L W H PACKING 0 5Kg 24pcs 13Kg 0 75CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature 2 Ripple noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1 uf 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 Please refer to OLP characteristics 5 Derating may be needed under low input voltage Please check the derating curve for more details 6 Output voltage can be adjusted through the SVR1 on the PCB limit of output constant current level can be adjusted through the SVR2 on the PCB 7 Constant current operation region is within 70 100 rated output voltage This is the suitable operation region for LED related applications File Name PLN SO SPEC 2007 12 24

Скачать