Daikin FXSQ80MVE [5/22] Specifications
![Daikin FXSQ80MVE [5/22] Specifications](/views2/1704912/page5/bg5.png)
• Indoor Units • Concealed Ceiling Unit • FXSQ-MVE9
1
1
•VRV
®
Systems • Indoor Units
4
1 Specifications
Standard Accessories Operation manual
Installation manual
Paper pattern for installation
Drain hose
Clamp metal
Insulation for fitting
Sealing pads
Clamps
Screws
Washer
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature
: 35°CDB, equivalent refrigerant piping : 7.5m (horizontal)
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB,
6°CWB, equivalent refrigerant piping : 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
1-2 Electrical Specifications (50Hz) FXSQ20MVE9 FXSQ25MVE9 FXSQ32MVE9 FXSQ40MVE9 FXSQ50MVE9 FXSQ63MVE9
Power Supply Name VE
Phase 1~
Frequency Hz 50
Voltage V 220-240
Current Minimum circuit amps (MCA) A 0.5 0.5 0.5 0.6 0.9 1.1
Maximum fuse amps (MFA) A 15 15 15 15 15 15
Full load amps (FLA) A 0.4 0.4 0.4 0.5 0.7 0.9
Voltage range Minimum V -10%
Maximum V +10%
Notes Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker
1-2 Electrical Specifications (50Hz) FXSQ80MVE9 FXSQ100MVE9 FXSQ125MVE9
Power Supply Name VE
Phase 1~
Frequency Hz 50
Voltage V 220-240
Current Minimum circuit amps (MCA) A 1.4 1.5 2.0
Maximum fuse amps (MFA) A 15 15 15
Full load amps (FLA) A 1.1 1.2 1.6
Voltage range Minimum V -10%
Maximum V +10%
Notes Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker
1-1 Technical Specifications FXSQ80MVE9 FXSQ100MVE9 FXSQ125MVE9
Содержание
- Air conditioning systems 1
- Technical data 1
- Capacity table 2
- Centre of gravity 2
- Cooling capacity tables 2
- Dimensional drawing 2
- Dimensional drawing centre of gravit 2
- Electrical specifications 50hz 2
- Electrical specifications 60hz 2
- Fan characteristic 2
- Heating capacity tables 2
- Option 2
- Piping diagra 2
- Safety device setting 2
- Sound dat 2
- Sound pressure spectrum 2
- Specification 2
- Table of contents fxsq mve9 2
- Technical specifications 2
- Wiring diagra 2
- Wiring diagram 2
- 1 technical specifications 3
- Specifications 3
- 1 technical specifications 4
- Specifications 4
- 1 technical specifications 5
- 2 electrical specifications 50hz 5
- Specifications 5
- 2 electrical specifications 60hz 6
- 3 electrical specifications 60hz 6
- Specifications 6
- Indoor units concealed ceiling unit fxsq mve9 7
- Options 7
- Safety device settings 7
- Systems indoor units 6 7
- 1 cooling capacity tables 8
- Capacity tables 8
- 1 cooling capacity tables 9
- Capacity tables 9
- 2 heating capacity tables 10
- Capacity tables 10
- 2 heating capacity tables 11
- Capacity tables 11
- 1 dimensional drawing 12
- Dimensional drawing centre of gravity 12
- Nr name description 12
- 1 dimensional drawing 13
- Dimensional drawing centre of gravity 13
- 1 dimensional drawing 14
- Dimensional drawing centre of gravity 14
- Nr name description 14
- 1 dimensional drawing 15
- Dimensional drawing centre of gravity 15
- Nr name description 15
- 2 centre of gravity 16
- Dimensional drawing centre of gravity 16
- Indoor units concealed ceiling unit fxsq mve9 17
- Piping diagram 17
- Systems indoor units 16 17
- 1 wiring diagram 18
- Wiring diagram 18
- 1 sound pressure spectrum 19
- Sound data 19
- 1 sound pressure spectrum 20
- Sound data 20
- Fan characteristics 21
- Indoor units concealed ceiling unit fxsq mve9 21
- Systems indoor units 20 21
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu btw be 0412 120 336 rpr oostende 22
Похожие устройства
- Daikin FXSQ80MVE Инструкция по эксплуатации
- Daikin FXSQ80MVE Сервис мануал
- Daikin FXSQ100MVE Технические данные
- Daikin FXSQ100MVE Инструкция по эксплуатации
- Daikin FXSQ100MVE Сервис мануал
- Daikin FXSQ125MVE Технические данные
- Daikin FXSQ125MVE Инструкция по эксплуатации
- Daikin FXSQ125MVE Сервис мануал
- Daikin FXSYQ20MVE Технические данные
- Daikin FXSYQ25MVE Технические данные
- Daikin FXSYQ32MVE Технические данные
- Daikin FXSYQ40MVE Технические данные
- Daikin FXSYQ50MVE Технические данные
- Daikin FXSYQ63MVE Технические данные
- Daikin FXSYQ80MVE Технические данные
- Daikin FXSYQ100MVE Технические данные
- Daikin FXSYQ125MVE Технические данные
- Zkteco D1 Техническое описание
- Zkteco D1 Руководство пользователя
- Zkteco D2 Руководство пользователя