100W Constant Power Mode LED Driver
XBG-100 series
SPECIFICATION
MODEL
DEFAULT CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ. RANGE
VOLTAGE RANGE Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
MTBF
DIMENSION
OTHERS
OVER VOLTAGE
OVER TEMPERATURE
875~2780mA
47 ~ 63Hz
1.1A / 115VAC 0.5A / 230VAC 0.42A / 277VAC
<0.75mA / 277VAC
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH non-condensing
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
727.29K hrs min. Telcordia SR-332(Bellcore) ;188.8K hrs min. MIL-HDBK-217F (25)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
92%
2100mA
100W
1750~2780mA
COLD START 50A(twidth=400 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-PE:2KVAC O/P-PE:1.5KVAC
I/P-O/P, I/P-PE, O/P-PE:100M Ohms / 500VDC / 25/ 70% RH
CONSTANT CURRENT REGION
PACKING
0.8Kg; 16pcs/ 14.8Kg/1.57CUFT
NOTE
μ
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
8 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
Constant current limiting or Hiccup mode, recovers automatically after fault condition is removed
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 305VAC
27 ~ 56V
OPEN CIRCUIT VOLTAGE (max.)
60V
61 ~ 78V
Shut down output voltage, re-power on after fault condition is removed to recover
TEMP. COEFFICIENT
±0.03%/ (0 ~ 60)
WORKING TEMP.
Tcase=-40 ~ +85(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase=+85
PF 0.97 / 115VAC, PF 0.95 / 230VAC full load , PF0.92 / 277VAC at
(Please refer to " " )Power Factor Characteristic section
THD< 10% (@ load50% at 115VAC/230VAC ,@load75% at 277VAC)
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
CURRENT RIPPLE 3.0% max. @rated current
CURRENT TOLERANCE ±5%
SET UP TIME Note.4 500ms/230VAC, 1200ms/115VAC
STANDBY
POWER CONSUMPTION
Standby power consumption<0.5W for AB-Type
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;
GB19510.1,GB19510.14; IP67 approved
LIFETIME Note.5
50000 hrs min.
φ130mm *56mm(D*H)






 






XBG-100- -
EMC IMMUNITY
EMC EMISSION
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Standard
EN61000-3-2
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level/Note
-----
-----
Class C @load≥50%
-----
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
4KV/Line-Line 6KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55015(CISPR15)
EN55015(CISPR15)
OVER POWER
Hiccup mode, recovers automatically after fault condition is removed
105-150%
File Name:XBG-100-SPEC 2020-01-02