TRACO POWER TPP 100-115 [2/4] Tpp 100 series 100 watt
![TRACO POWER TPP 100-136 [2/4] Tpp 100 series 100 watt](/views2/1708387/page2/bg2.png)
Input Voltage
- AC Range
85 - 264 VAC (Full Range)
- DC Range
120 - 370 VDC (Designed for, no certification)
Input Frequency
47 - 63 Hz
Input Current
- Full Load & Vin = 230 VAC
550 mA max.
- Full Load & Vin = 115 VAC
1'150 mA max.
Power Consumption
- At no load
300 mW max. (Ready to meet ErP directive)
Input Inrush Current
- at 230 VAC
60 A max.
Power Factor
- at 230 VAC
0.95 min. (Active Power Factor Correction)
- at 115 VAC
0.95 min. (Active Power Factor Correction)
Input Protection
T 3.15 A / 250 VAC (Internal Fuse in L & N)
Input Specifications
Output Voltage Adjustment
±10% (By trim potentiometer)
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (0 - 100%)
0.5% max.
Ripple and Noise
(20 MHz Bandwidth)
12 VDC model:
120 mVp-p typ. (with 10 uF X7R)
15 VDC model:
150 mVp-p typ. (with 10 µF X7R)
24 VDC model:
160 mVp-p typ. (with 1 µF X7R)
28 VDC model:
180 mVp-p typ. (with 1 µF X7R)
36 VDC model:
190 mVp-p typ. (with 1 µF X7R)
48 VDC model:
340 mVp-p typ. (with 0.1 µF X7R)
Capacitive Load
12 VDC model:
6'950 µF max.
15 VDC model:
4'450 µF max.
24 VDC model:
1'750 µF max.
28 VDC model:
1'280 µF max.
36 VDC model:
770 µF max.
48 VDC model:
430 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
- at 230 VAC
16 ms min.
- at 115 VAC
16 ms min.
Start-up Time
- at 230 VAC
1'000 ms max.
- at 115 VAC
1'000 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
115 - 150% of Iout max.
Overvoltage Protection
115 - 135% of Vout nom.
Transient Response
- Response Deviation
3 % max. (50% to 75% Load Step)
- Response Time
500 µs typ. (50% to 75% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
IEC 60950-1
EN 60950-1
UL 60950-1
- Medical Equipment
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Certification Documents
www.tracopower.com/overview/tpp100
Protection Class
Class I (Prepared): Connection to PE
Class II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
TPP 100 Series, 100 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
January 9, 2020
Page 2 / 4
Содержание
- Ac dc medical power supply tpp 100 series 100 watt 1
- Acceptance criteria for electronic assemblies acc to ipc a 610 level 3 1
- Certification according to iec en es 60601 1 3rd edition for 2 x mopp 1
- Encased 100 w power supply with screw connection in 2 4 x 3 package 1
- Low leakage current 75 µa rated for bf applications 1
- Models 1
- Operating up to 5000 m altitude 1
- Protection class l and ll prepared 1
- Ready to meet erp directive 0 w no load power consumption 1
- Risk management process according to iso 14971 incl risk management file 1
- Year product warranty 1
- Input specifications 2
- Output specifications 2
- Safety specifications 2
- Tpp 100 series 100 watt 2
- Emc specifications 3
- General specifications 3
- Tpp 100 series 100 watt 3
- Con1 terminal block mates with screw locked torque max 2kgf cm 0 n m wire dimension range 26 16 awg 4
- Con2 terminal block mates with screw locked torque max 2kgf cm 0 n m wire dimension range 26 16 awg 4
- Copyright 2019 traco electronic ag specifications can be changed without notice 4
- Outline dimensions 4
- Screw terminal 4
- Supporting documents 4
- Tpp 100 series 100 watt 4
- Www tracopower com 4
Похожие устройства
- TRACO POWER TPP 100-124 Инструкция по эксплуатации
- TRACO POWER TPP 100-124 Инструкция по установке
- TRACO POWER TPP 100-124 Datasheet
- TRACO POWER TPP 100-124 Документация
- Biostar Hi-Fi B350S1 Версия 6.x Руководство пользователя
- TRACO POWER TPP 100-128 Инструкция по эксплуатации
- TRACO POWER TPP 100-128 Инструкция по установке
- TRACO POWER TPP 100-128 Datasheet
- TRACO POWER TPP 100-128 Документация
- Biostar Hi-Fi A55S2 Версия 6.x Руководство пользователя
- TRACO POWER TPP 100-136 Инструкция по эксплуатации
- TRACO POWER TPP 100-136 Инструкция по установке
- TRACO POWER TPP 100-136 Документация
- TRACO POWER TPP 100-136 Datasheet
- Biostar Hi-Fi A55S3 Версия 6.1 Руководство пользователя
- TRACO POWER TPP 100-148 Инструкция по эксплуатации
- TRACO POWER TPP 100-148 Инструкция по установке
- TRACO POWER TPP 100-148 Документация
- TRACO POWER TPP 100-148 Datasheet
- Biostar Hi-Fi A75S3 Версия 6.3 Руководство пользователя