Daikin RXY32MYL [3/346] Protection control 05

Daikin RXY36MYL [3/346] Part 5 test operation 21
Si38-304
ii Table of Contents
3.3 Defrosting Operation ..............................................................................99
3.4 Pump-down Residual Operation ..........................................................100
3.5 Restart Standby....................................................................................101
3.6 Stopping Operation ..............................................................................102
3.7 Pressure Equalization prior to Startup..................................................104
4. Protection Control ...............................................................................105
4.1 High Pressure Protection Control.........................................................105
4.2 Low Pressure Protection Control..........................................................106
4.3 Discharge Pipe Protection Control .......................................................107
4.4 Inverter Protection Control ...................................................................108
4.5 STD Compressor Overload Protection.................................................109
4.6 Crankcase Heater Control....................................................................109
5. Other Control.......................................................................................110
5.1 Outdoor Unit Rotation...........................................................................110
5.2 Emergency Operation ..........................................................................111
5.3 Demand Operation ...............................................................................113
5.4 Heating operation prohibition ...............................................................113
6. Outline of Control (Indoor Unit) ...........................................................114
6.1 Drain Pump Control..............................................................................114
6.2 Louver Control for Preventing Ceiling Dirt............................................116
6.3 Thermostat Sensor in Remote Controller.............................................117
6.4 Freeze Prevention ................................................................................119
Part 5 Test Operation ............................................................... 121
1. Test Operation ....................................................................................122
1.1 Procedure and Outline .........................................................................122
1.2 Operation When Power is Turned On ..................................................125
2. Outdoor Unit PC Board Layout ...........................................................126
3. Field Setting ........................................................................................127
3.1 Field Setting from Remote Controller ...................................................127
3.2 Field Setting from Outdoor Unit............................................................139
Part 6 Troubleshooting .............................................................163
1. Troubleshooting by Remote Controller ...............................................165
1.1 The INSPECTION / TEST Button.........................................................165
1.2 Self-diagnosis by Wired Remote Controller .........................................166
1.3 Self-diagnosis by Wireless Remote Controller .....................................167
1.4 Operation of The Remote Controller’s Inspection /
Test Operation Button ..........................................................................170
1.5 Remote Controller Service Mode .........................................................171
1.6 Remote Controller Self-Diagnosis Function .........................................173
2. Troubleshooting by Indication on the Remote Controller ....................178
2.1 A0” Indoor Unit: Error of External Protection Device ...........................178
2.2 A1” Indoor Unit: PC Board Defect.........................................................179
2.3 A3” Indoor Unit: Malfunction of Drain Level Control System (33H)......180
2.4 A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................182
2.5 A7” Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................183
2.6 A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E) ........................................................185
2.7 AF” Indoor Unit: Drain Level above Limit..............................................187