Daikin RXYQ12MAY1 [31/352] Specifications

Daikin RXYQ26MAY1 [31/352] Specifications
Specifications SiE39-407
20 Specifications
Notes:
H1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
H2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
H3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference
: 0m.
Model Name (Combination Unit) RXYQ46MAY1 RXYQ48MAY1
Model Name (Independent Unit) RXYQ14MAY1+RXYQ16MAY1+RXYQ16MAY1 RXYQ16MAY1+RXYQ16MAY1+RXYQ16MAY1
H1 Cooling Capacity (19.5°CWB)
kcal / h 113,000 117,000
Btu / h 447,000 464,000
kW 131 136
H2 Cooling Capacity (19.0°CWB) kW 130 135
H3 Heating Capacity
kcal / h 125,000 129,000
Btu / h 496,000 513,000
kW 145 150
Casing Color Ivory White (5Y7.5/1) Ivory White (5Y7.5/1)
Dimensions: (H×W×D) mm (1600×1240×765)+(1600×1240×765)+(1600×1240×765) (1600×1240×765)+(1600×1240×765)+(1600×1240×765)
Heat Exchanger Cross Fin Coil Cross Fin Coil
Comp.
Type Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type
Piston Displacement m³/h (13.72+10.53+10.53)×3 (13.72+10.53+10.53)×3
Number of Revolutions r.p.m (6480, 2900×2)×3 (6480, 2900×2)×3
Motor Output×Number
of Units
kW (1.1+4.5+4.5)+(2.7+4.5+4.5)×2 (2.7+4.5+4.5)×3
Starting Method Direct on line Direct on line
Fan
Type Propeller Fan Propeller Fan
Motor Output kW 0.75×3 0.75×3
Air Flow Rate m³/min 210+210+210 210+210+210
Drive Direct Drive Direct Drive
Connecting
Pipes
Liquid Pipe mm φ19.1 (Brazing Connection) φ19.1 (Brazing Connection)
Gas Pipe mm φ41.3 (Brazing Connection) φ41.3 (Brazing Connection)
Product Mass (Machine Weight) kg 312+312+312 312+312+312
Safety Devices
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
Defrost Method Deicer Deicer
Capacity Control % 3~100 3~100
Refrigerant
Refrigerant Name R410A R410A
Charge kg 11.6+12.4+12.4 12.4+12.4+12.4
Control Electronic Expansion Valve Electronic Expansion Valve
Refrigerator Oil Refer to the nameplate of compressor Refer to the nameplate of compressor
Standard Accessories
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Drawing No. C: 4D048272, 4D048273 C: 4D048273
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3