ADJUSTMENT (Refer to figure 4)
For adjustment the desired temperature, fan
speed and air flow direction (only for the
remote controller BRC1A51: FXC, FXF, FXH,
FXK, FXA), follow the procedure shown below.
Press the temperature setting button and set
the desired temperature.
Each time this button is pressed, the tem-
perature setting rises or lowers 1°C.
NOTE
•
Set the temperature within the operation range.
• The temperature setting is impossible for fan
only operation.
Press the fan speed control button and select
the fan speed of your preference.
NOTE
• For machine protection the system may con-
trol the air flow rate automatically.
• The air flow rate may be adjusted automati-
cally depending on the room temperature or
the fan may stop immediately. This is not a
malfunction.
• It may take sometime for finishing to change
the air flow rate.
This is normal operation.
Press air flow direction adjust button.
Refer to the chapter “6-3 ADJUSTING THE
AIR FLOW DIRECTION” for details.
STOPPING THE SYSTEM (Refer to figure 4)
Press the on/off button once again.
The operation lamp goes off and the system
stops operation.
NOTE
• The fan may keep on running for about
1 minute after the heating operation stops
for removing the heat in the indoor unit.
• Do not turn off the power immediately after
the unit stops.
The system need at least 5 minutes for
residual operation of drain pump device.
Turning off the power immediately will cause
water leak or trouble.
EXPLANATION OF HEATING OPERATION
•
In general, heating operation may take longer to
reach the set temperature than in cooling operation.
We recommend starting the operation which was
used before using timer operation.
• The following operation is performed in order to
prevent the heating capacity from dropping or
cold air from blowing.
Defrost operation
• In heating operation, freezing of the outdoor
unit heat exchanger increases. Heating
capability decreases and the system goes
into defrost operation.
• The airflow will be set to breeze or stop.
• If stopped, the display of the remote control-
ler shows “ ”.
• Once the airflow is set to breeze or stop, the
air conditioner will return to the previous
state in approximately 5 to 15 minutes.
Hot start
• In order to prevent cold air from blowing out
of an indoor unit at the start of heating oper-
ation, the indoor fan is automatically
stopped. The display of the remote controller
shows
“”
.
• The heating capacity drops as the outside tem-
perature falls. If this happens, use another heat-
ing device together with the unit. (When using the
appliances which produce open fire together, ven-
tilate a room constantly.)
Do not place appliances which produce open fire
in places exposed to the air flow from the unit or
under the unit.
•
It takes some time for the room to warm up from
the time the unit is started since the unit is a hot-air
circulatory system to warm the entire room.
• If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend using the cir-
culator (the indoor fan for circulating air). Contact
your dealer for details.
6-2 PROGRAM DRY OPERATION
•
The program dry function deprives the room
of moisture while the air conditioner is in inter-
mittent weak cooling operation so that the
room temperature will not become too low.
• The microcomputer automatically controls
the temperature and fan speed, so these
cannot be set using the remote controller.
• This function is not available if the room tem-
perature is 20°C or lower.
• This function does not controls the humidity.
• FXL and FXN type indoor unit can not oper-
ate program dry operation.
FOR SYSTEMS WITHOUT COOL/HEAT SELEC-
TOR (Refer to figure 5)
NOTE
• If
“”
(Cooling operation) is not displayed, refer
to “6-1 COOLING, HEATING, AUTOMATIC AND
FAN ONLY OPERATION”, and set
“”
(Cooling
operation).
Unless the air conditioner is set to
“”
(Cooling
operation), the air conditioner cannot be switched
over to
“”
(program dry operation).
3
4
5
6
01_EN_3P201178-1C.fm Page 7 Wednesday, April 25, 2007 11:41 AM
Содержание
- Operation manual 1
- System air conditioner 1
- _cv_3p201178 1c fm page 4 thursday april 19 2007 3 21 pm 4
- Contents 5
- Read the following cautions carefully and use your equipment properly 5
- Safety cautions 5
- 1 refrigerant charge at factory shipment 7
- Arrange the drain hose to ensure smooth drainage incomplete drainage may cause water leakage 7
- Be sure to use the following places a places that can sufficiently withstand the weight of the air conditioner and suppress the operat ing sound and vibration of the air conditioner b places where warm air from the air outlet of the outdoor unit or the operating sound of the out door unit does not annoy neighbors 7
- Caution for installation 7
- Consult with your dealer for electrical work and grounding work 7
- Consult your dealer if the air conditioner in operation generates unusual noise 7
- Do not install the air conditioner in places where flammable gas may leak out leaked gas may accumulate around the unit causing an explosion 7
- Do not locate the remote controller in a spot splashed with water water coming inside the machine may cause elec tric shocks or may damage the internal electronic parts 7
- Do not use the air conditioner in the following places a places with a mist of mineral oil such as cutting oil b locations such as coastal areas where there is a lot of salt in the air c locations such as hot springs resorts where there is a lot of sulfur in the air d locations such as factories where the power voltage varies a lot e in cars boats and other vehicles f locations such as kitchens where oil may splat ter or there is steam in the air g locations where equipment that produces elec tromagnetic waves is found h places with an acid or alkaline mist i places where fallen leaves are accumulated or weeds grow close together 7
- Drainage through drainpipe 7
- Electrical work 7
- English 3 7
- For refrigerant leakage consult your dealer refrigerant leakage in excess of the level of con centration limits may result in oxygen deficiency when the air conditioner is installed in a small room it is necessary to take proper measures so that the amount of any leaked refrigerant will not exceed the limiting concentration even if it leaks 7
- Make sure that the air conditioner is located in a sufficiently ventilated place not surrounded by obstacles 7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer 7
- Make sure that there are no obstacles close to the outdoor unit obstacles close to the outdoor unit may drop the performance of the outdoor unit or an increase in the operating sound of the outdoor unit 7
- Pay attention to operating sound 7
- Place of installation 7
- Single outdoor unit system 7
- Specifications 7
- Take snow protection measures contact your dealer for the details of snow protec tion measures such as the use of a snow protec tion hood 7
- Use a dedicated circuit for the air conditioner 7
- 1 refrigerant charge at factory shipment 8
- English 8
- Multi outdoor unit system 8
- Remote controller and cool heat selector name and function of each switch and display 9
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 9
- What to do before operation 9
- 1 cooling heating automatic and fan only operation 10
- Operation procedure 10
- Operation range 10
- 2 program dry operation 11
- 3 adjusting the air flow direction refer to figure 6 only for double flow multi flow corner ceiling suspended and wall mounted 12
- 4 programming start and stop of the system with timer refer to figure 9 12
- 5 setting the master remote con troller 13
- 1 at the beginning of the season 14
- 6 precautions for group con trol system or two remote con troller control system 14
- Optimum operation 14
- Seasonal maintenance 14
- 1 the system does not operate 15
- 2 at the end of the season 15
- 2 it stops sometimes 15
- 3 cool heat cannot be changed over 15
- 4 fan operation is possible but cooling and heating do not work 15
- 5 the fan strength does not cor respond to the setting 15
- 6 the fan direction does not cor respond to the setting 15
- 7 white mist comes out of a unit 15
- Following symptoms are not air conditioner troubles 15
- 10 the units can give off odours 16
- 11 the outdoor unit fan does not spin 16
- 12 the display shows 16
- 13 the compressor or fan in the outdoor unit does not stop 16
- 14 the inside of an outdoor unit is warm even when the unit has stopped 16
- 15 hot air is emitted even though the unit is stopped 16
- 16 does not cool very well 16
- 8 noise of air conditioners 16
- 9 dust comes out of the unit 16
- After sales service and warranty 17
- Trouble shooting 17
Похожие устройства
- Daikin REYQ8PY1B Технические данные
- Daikin REYQ10PY1B Технические данные
- Daikin REYQ12PY1B Технические данные
- Daikin REYQ14PY1B Технические данные
- Daikin REYQ16PY1B Технические данные
- Daikin REYQ8PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ10PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ8PY1B Инструкция по монтажу
- Daikin REYQ10PY1B Инструкция по монтажу
- Daikin REYQ12PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ8PY1B Инструкция по эксплуатации
- Daikin REYQ10PY1B Инструкция по эксплуатации
- Daikin REYQ12PY1B Инструкция по монтажу
- Daikin REYQ8PY1B Спецификация
- Daikin REYQ10PY1B Спецификация
- Daikin REYQ14PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ16PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ12PY1B Инструкция по эксплуатации
- Daikin REYQ14PY1B Инструкция по монтажу
- Daikin REYQ16PY1B Инструкция по монтажу