Daikin RXYQ12P7W1B [31/80] Vrviii heat pump small footprint combination

Daikin RXYQ10P7W1B [31/80] Vrviii heat pump small footprint combination
RXYQ-P(A)
Nominal capacity cooling kW
heating kW
COP cooling
heating
Capacity range HP
Power input (nominal) cooling kW
heating kW
Max n° of indoor units to be connected
Indoor index connection minimum
maximum
Casing colour
material
Dimensions unit height mm
width mm
depth mm
Weight unit kg
Fan type
air flow rate cooling m
3
/min
(nominal at 230V)
heating m
3
/min
external static pressure (MAX) Pa
Compressor type
Operation range cooling minimum °CDB
maximum °CDB
heating minimum °CWB
maximum °CWB
Sound level (nominal) cooling sound power dBA
sound pressure dBA
Refrigerant type
charge kg
control
Refrigerant Oil type
charged Volume l
Piping Connections liquid type
diameter (OD) mm
gas type
diameter (OD) mm
heat insulation
max. total length m
Defrost method
Defrost control
Capacity control method
Capacity control [%]
Safety devices
Power supply name
phase
frequency Hz
voltage V
RXYQ5P7W1B RXYQ8P7W1B RXYQ10P7W1B RXYQ12P7W1B
RXYQ14P7W1BA RXYQ16P7W1BA RXYQ18P7W1BA
14.0 22.4 28.0 33.5 40.0 45.0 49.0
16.0 25.0 31.5 37.5 45.0 50.0 56.5
3.98 4.03 3.77 3.48 3.23 3.17 3.02
4.00 4.27 4.09 3.97 3.98 3.88 3.69
5 8 10 12 14 16 18
3.52 5.56 7.42 9.62 12.4 14.2 16.2
4.00 5.86 7.70 9.44 11.30 12.90 15.30
8 13 16 19 23 26 29
62.5 100 125 150 175 200 225
162.5 260 325 390 455 520 585
Daikin White
Painted galvanised steel
1,680 1,680 1,680 1,680 1,680 1,680 1,680
635 930 930 930 1,240 1,240 1,240
765 765 765 765 765 765 765
159 187 240 240 316 316 324
Propeller
95 171 185 196 233 233 239
95 171 185 196 233 233 239
78Pa in high static pressure
Hermetically sealed scroll compressor
-5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0
43.0 43.0 43.0 43.0 43.0 43.0 43.0
-20.0 -20.0 -20.0 -20.0 -20.0 -20.0 -20.0
15.0 15.0 15.0 15.0 15.0 15.0 15.0
72 78 78 80 80 80 83
54 57 58 60 60 60 63
R-410A
6.2 7.7 8.4 8.6 11.3 11.5 11.7
Expansion valve (electronic type)
Synthetic (ether) oil
1.7 2.1 3.9 3.9 5.7 5.7 5.8
Braze connection
9.52 9.52 9.52 12.7 12.7 12.7 15.9
Braze connection
15.9 19.1 22.2 28.6 28.6 28.6 28.6
Both liquid and gas pipes
1,000 1,000 1,000 1,000 1,000 1,000 1,000
Reversed cycle
Sensor for outdoor heat exchanger temperature
Inverter controlled
~ 100 ~ 100 ~ 100 ~ 100 ~ 100 ~ 100 ~ 100
HPS, fan motor driver overload protector, overcurrent relay, inverter overload protector, PC board fuse
W1 W1 W1 W1 W1 W1 W1
3N~ 3N~ 3N~ 3N~ 3N~ 3N~ 3N~
50 50 50 50 50 50 50
400 400 400 400 400 400 400
VRVIII HEAT PUMP - SMALL FOOTPRINT COMBINATION
Outdoor Units
p. 31
Notes: Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m
Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment.
Sound values are measured in a semi-anechoic room.
3
1602UKEPCEN07-200-artwork.indd 311602UKEPCEN07-200-artwork.indd 31 1/8/07 07:15:111/8/07 07:15:11