Daikin RXYQ14P7W1B [5/12] Explanation of heating operation
![Daikin RXYQ32P7W1B [5/12] Procedure](/views2/1714011/page5/bg5.png)
RX(Y)Q5~18P7W1B + RXYQ8~18P7W1B1 + RXYSQ4~6P7V3B
VRVIII and VRVIII-S system air conditioner
4PW28160-1A
Operation manual
3
5. O
PERATION
RANGE
Operation range
Use the system in the following temperature and humidity ranges for
safe and effective operation.
6. O
PERATION
PROCEDURE
■
Operation procedure varies according to the combination of
outdoor unit and remote controller. Read "2. What to do before
operation" on page 2.
■
To protect the unit, turn on the main power switch 6 hours before
operation.
■
If the main power supply is turned off during operation, operation
will restart automatically after the power turns back on again.
6.1. Cooling, heating, fan only, and automatic
operation
(See figure 3 and figure 4.1)
■
Changeover cannot be made with a remote controller whose
display shows (change-over under centralized control).
■
When the display (change-over under centralized control)
flashes, refer to "6.4. Setting the master remote controller" on
page 4.
■
RXQ series let you select fan only and cooling operation.
■
The fan may keep on running for about 1 minute after the
heating operation stops.
■
The air flow rate may adjust itself depending on the room
temperature or the fan may stop immediately. This is not a
malfunction.
For systems without cool/heat changeover remote control
switch (See figure 3)
1
Press the operation mode selector button several times and
select the operation mode of your choice.
2
Press the on/off button.
The operation lamp lights up and the system starts operation.
For systems with cool/heat changeover remote control switch
1
Select operation mode with the cool/heat changeover remote
control switch as follows:
2
Press the on/off button.
The operation lamp lights up and the system starts operation.
Adjustment
For programming temperature, fan speed and air flow direction, refer
to the operation manual of the remote controller.
Stopping the system
3
Press the on/off button once again.
The operation lamp goes off and the system stops operation.
Explanation of heating operation
It may take longer to reach the set temperature for general heating
operation than for cooling operation.
The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.
Defrost operation (heat pump and heat recovery types only)
■ In heating operation, freezing of the outdoor unit coil increases.
Heating capability decreases and the system goes into defrost
operation.
■ The indoor unit fan stops and the remote controller displays
.
■ After maximum 10 minutes of defrost operation, the system
returns to heating operation again.
Hot start (heat pump and heat recovery types only)
■ In order to prevent cold air from blowing out of an indoor unit at
the start of heating operation, the indoor fan is automatically
stopped. The display of the remote controller shows .
It may take some time before the fan starts. This is not a
malfunction.
RXQ5~18
RXYQ5~18
RXYSQ4~6
COOLING COOLING HEATING
Outdoor temperature
–5~43°C DB –5~46°C DB
–20~24°C DB
(*)
(*) Range for operation: –20~–15°C WB. Range for continuous operation:
–15~15.5°C WB.
–20~15.5°C WB
Indoor temperature
21~32°C DB 21~32°C DB 15~27°C DB
14~25°C WB 14~25°C WB
Indoor humidity
≤80%
(†)
(†) to avoid condensation and water dripping out the unit.
If the temperature or the humidity is beyond these conditions, safety devices may
work and the air conditioner may not operate.
≤80%
(†)
≤80%
(†)
Cooling operation
Heating operation
Fan only operation
Cooling operation (figure 4.1)
Heating operation (figure 4.2)
Fan only operation (figure 4.3)
NOTE
Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.
NOTE
■ The heating capacity drops when the outside
temperature falls. If this happens, use another
heating device together with the unit. (When using
together with appliances that produce open fire,
ventilate the room constantly.)
Do not place appliances that produce open fire in
places exposed to the air flow from the unit or
under the unit.
■ It takes some time to heat up the room from the
time the unit is started since the unit uses a hot-air
circulating system to heat the entire room.
■ If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend that you use
the circulator (the indoor fan for circulating air).
Contact your dealer for details.
Содержание
- And system air conditioner 1
- Operation manual 1
- Cautions 3
- Operation manual 3
- Safety cautions 3
- Before 4
- Cautions 4
- Changeover switch name and function of each switch 4
- Controller 4
- Function 4
- Hangeover 4
- Operation 4
- Remote controller 4
- Switch 4
- What to do before operation 4
- Cooling heating fan only and automatic operation 5
- Explanation of heating operation 5
- For systems with cool heat changeover remote control switch 5
- For systems without cool heat changeover remote control 5
- Operation procedure 5
- Operation range 5
- Peration 5
- Procedure 5
- Switch see figure 3 5
- Adjusting the air flow direction 6
- Adjusting the air flow direction 6
- For systems with cool heat changeover remote control switch see figure 5 6
- For systems without cool heat changeover remote control switch 6
- Movement of the air flow flap see figure 7 6
- Program dry operation 6
- Setting the master remote controller 6
- Aintenance 7
- Energy saving and optimum operation 7
- Following symptoms are not air conditioner troubles 7
- Maintenance 7
- Maintenance after a long stop period 7
- Maintenance before a long stop period 7
- Nergy saving and optimum operation 7
- Ollowing symptoms are not air conditioner troubles 7
- Precautions for group control system or two remote controller control system 7
- Roubleshooting 8
- Troubleshooting 8
- After sales service 9
- After sales service and warranty 9
- Sales service and warranty 9
- Shortening of maintenance cycle and replacement cycle needs to be considered in followi 10
- Shortening of maintenance cycle and replacement cycle needs to be considered in following situations 10
- Pw28160 1a 12
Похожие устройства
- Daikin RXYQ12P7W1B Инструкция по эксплуатации
- Daikin RXYQ20P7W1B Руководство по вводу в эксплуатацию
- Daikin RXYQ22P7W1B Руководство по вводу в эксплуатацию
- Daikin RXYQ20P7W1B Инструкция по монтажу
- Daikin RXYQ24P7W1B Руководство по вводу в эксплуатацию
- Daikin RXYQ26P7W1B Руководство по вводу в эксплуатацию
- Daikin RXYQ28P7W1B Руководство по вводу в эксплуатацию
- Daikin RXYQ28P7W1B Инструкция по монтажу
- Daikin RXYQ26P7W1B Инструкция по монтажу
- Daikin RXYQ24P7W1B Инструкция по монтажу
- Daikin RXYQ22P7W1B Инструкция по монтажу
- Daikin RXYQ20P7W1B Технические данные
- Daikin RXYQ22P7W1B Технические данные
- Daikin RXYQ24P7W1B Технические данные
- Daikin RXYQ26P7W1B Технические данные
- Daikin RXYQ28P7W1B Технические данные
- Daikin RXYQ20P7W1B Спецификация
- Daikin RXYQ22P7W1B Спецификация
- Daikin RXYQ24P7W1B Спецификация
- Daikin RXYQ26P7W1B Спецификация