1-2 Specifications
[Single unit]
*1:Initial refrigerant charge
[Combination unit]
RXYQ20~54PY1 or RXQ20~54PY1 is the combination unit that is com-
posed of the single units.
About the specifications see Single unit according to the indepen-
dent unit.
1-3 What to do before Operation
This operation manual is for the following system with standard con-
trol. Before initiating operation, contact your Daikin dealer for the
operation that corresponds to your system type and mark.
If your installation has a customized control system, ask your Daikin
dealer for the operation that corresponds to your system.
Outdoor units (Refer to figure 1)
Names and functions of parts (Refer to figure 1)
(figure 1 shows system with Cool/Heat selector)
Model
RXYQ5PY1 RXYQ8PY1 RXYQ10PY1
Power supply
Phase
-
3N
~
3N
~
3N
~
Frequency
(Hz)
50 50 50
Voltage
(V)
380-415 380-415 380-415
Nominal cooling capacity
(kW)
14.0 22.4 28.0
Nominal heating capacity
(kW)
16.0 25.0 31.5
Dimensions H×W×D
(mm)
1680×635×765 1680×930×765 1680×930×765
Mass
(kg)
160 205 249
Refrigerant type
-
R-410A R-410A R-410A
Refrigerant charge (*1)
(kg)
6.2 7.7 8.4
Design pressure
High pressure side
(bar)
40 40 40
(MPa)
4.0 4.0 4.0
Low pressure side
(bar)
33 33 33
(MPa)
3.3 3.3 3.3
Model
RXYQ12PY1
RXYQ14PY1 RXYQ16PY1
Power supply
Phase -
3N
~
3N
~
3N
~
Frequency (Hz) 50 50 50
Voltage (V) 380-415 380-415 380-415
Nominal cooling capacity
(kW) 33.5 40.0 45.0
Nominal heating capacity
(kW) 37.5 45.0 50.0
Dimensions H×W×D (mm)
1680×1240×765 1680×1240×765 1680×1240×765
Mass (kg) 285 329 329
Refrigerant type - R-410A R-410A R-410A
Refrigerant charge (*1) (kg) 10.0 12.3 12.5
Design pressure
High pressure side (bar) 40 40 40
(MPa) 4.0 4.0 4.0
Low pressure side (bar) 33 33 33
(MPa) 3.3 3.3 3.3
Model
RXYQ18PY1
Power supply
Phase
-
3N
~
Frequency
(Hz)
50
Voltage
(V)
380
-
415
Nominal cooling capacity
(kW)
49.0
Nominal heating capacity
(kW)
56.5
Dimensions H×W×D
(mm) 1680×1240×765
Mass
(kg)
341
Refrigerant type
-
R-410A
Refrigerant charge (*1)
(kg)
12.7
Design pressure
High pressure side
(bar)
40
(MPa)
4.0
Low pressure side
(bar)
33
(MPa)
3.3
Model
RXQ5PY1 RXQ8PY1 RXQ10PY1
Power supply
Phase -
3N
~
3N
~
3N
~
Frequency (Hz) 50 50 50
Voltage (V) 380-415 380-415 380-415
Nominal cooling capacity
(kW) 14.0 22.4 28.0
Dimensions H×W×D (mm) 1680×635×765 1680×930×765 1680×930×765
Mass (kg) 160 205 249
Refrigerant type - R-410A R-410A R-410A
Refrigerant charge (*1) (kg) 6.2 7.7 8.4
Design pressure
High pressure side (bar) 40 40 40
(MPa) 4.0 4.0 4.0
Low pressure side (bar) 33 33 33
(MPa) 3.3 3.3 3.3
Model RXQ12PY1 RXQ14PY1 RXQ16PY1
Power supply
Phase -
3N
~
3N
~
3N
~
Frequency (Hz) 50 50 50
Voltage (V) 380-415 380-415 380-415
Nominal cooling capacity
(kW) 33.5 40.0 45.0
Dimensions H×W×D (mm)
1680×1240×765 1680×1240×765 1680×1240×765
Mass (kg) 285 329 329
Refrigerant type - R-410A R-410A R-410A
Refrigerant charge (*1) (kg) 10.0 12.3 12.5
Design pressure
High pressure side (bar) 40 40 40
(MPa) 4.0 4.0 4.0
Low pressure side (bar) 33 33 33
(MPa) 3.3 3.3 3.3
Model RXQ18PY1
Power supply
Phase -
3N
~
Frequency (Hz) 50
Voltage (V)
380
-
415
Nominal cooling capacity
(kW) 49.0
Dimensions H×W×D (mm)
1680×1240×765
Mass (kg) 341
Refrigerant type - R-410A
Refrigerant charge (*1) (kg) 12.7
Design pressure
High pressure side (bar) 40
(MPa) 4.0
Low pressure side (bar) 33
(MPa) 3.3
Cool/Heat selector Operation modes
Inverter series
heat pumps RXYQ series * yes * no
cooling only RXQ series ———
figure 1
Outlet air
Inlet air
Cool/Heat selector
(except RXQ series)
Remote
control
Indoor
unit
Outdoor
unit
Inlet
air
Outlet
air

Содержание

Скачать