Daikin RXQ10PAY1 [6/36] An increased number of connectable indoor units

Daikin RXYQ14PAYL [6/36] An increased number of connectable indoor units
Main Features
Large capacities for large-sized buildings Large capacities for large-sized buildings
Conditions of indoor unit connection capacity
109
Piping length is drastically extended! The long piping length provides more design flexibility, which can match
even large-sized buildings.
Extended long piping length
The number of connectable indoor units has been drastically increased from 40 to 64!
An increased number of connectable indoor units
Connection capacity at maximum is 200%.
Connection ratio
40
64
Increased indoor unit connections
indoor
units
VRVII
MA series
VRVII MA series
indoor
units
Refer to page 26 for the maximum number of connectable indoor units.
Maximum number of connectable indoor units
Up to
Up to
150 m
165 m
175 m
190 m
510 m
1000 m
Max. equivalent piping length
Max. actual piping length
50 m
40 m
VRVII MA series
VRVII MA series
VRVII MA series
Note:
* For the FXFQ25 models, maximum connection ratio is 130% for the entire range of outdoor units.
If the operational capacity of indoor units is more than 130%, low airflow operation is enforced
in all the indoor units.
50%200%
Connection ratio
Single outdoor units
Double outdoor units
Triple outdoor units
FXDQ, FXMQ-P, FXAQ models
Applicable indoor units
200%
Other indoor
unit models*
200%
160%
130%
p
q
k
First outdoor branch
f
a
b
First
indoor branch
Multiple use
*The rest of indoor units are
the same as for single use.
a
i
s
r
h
g
f
e
d
c
b
First indoor branch
Single use
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
Max. total piping length
Max. level difference
between the outdoor units
and the indoor units
Outdoor unit
above indoor unit:
Outdoor unit above indoor unit:
2. Level differences above 50 m
are available on request.
Outdoor unit below indoor unit:
Outdoor unit above indoor unit:
Outdoor unit below indoor unit:
Outdoor unit
below indoor unit:
Connection ratio =
Total capacity index of the indoor units
Capacity index of the outdoor units
1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. Various conditions and
requirements have to be met to allow utilisation of 90 m piping length. Be sure to refer to the Engineering Data Book for details of these
conditions and requirements.
2. Level differences above 50 m are not supported by default but are available on request for RX(Y)Q8P(A)-54P(A) (If the outdoor unit is
above the indoor unit).
Maximum
allowable
level difference
Maximum
allowable
piping length
Between the outdoor units
and the indoor units
Between the indoor units
Between the outdoor units (Multiple use)
Between the first indoor branch and the farthest indoor unit
Between the outdoor branch and the last outdoor unit
Total piping length
Refrigerant piping length
15 m
90 m
5 m
90 m
q
s
r
r
a+b+c+d+e+f+g+h+i
a+f+g+h+i
f+g+h+i
k+p
165 m 190 m
1000 m
90 m*
*
1
10 m 13 m
Actual
piping length
Equivalent
piping length
Example
Level
Difference
Example
RX(Y)Q8P(A)-54P(A)
50 m
r
RX(Y)Q5P(A)
RX(Y)Q8P(A)-54P(A)
Outdoor Units
2 Available on request
If the outdoor unit is above.
If the outdoor unit is below.
If the outdoor unit is above.
If the outdoor unit is below.
40 m
r
90
m
2
RX(Y)Q8P(A)-54P(A)
90
m
40
m
50
m
RX(Y)Q5P(A)