Daikin RXQ24PAY1 [7/36] Higher external static pressure has been achieved thanks to the fan grilles and the dual dc fans that reduce internal pressure loss exceeding the previous 58 pa 6 mm

Daikin RXYQ14PAYL [7/36] Higher external static pressure has been achieved thanks to the fan grilles and the dual dc fans that reduce internal pressure loss exceeding the previous 58 pa 6 mm
Large capacities for large-sized buildings
Main Features
Easier installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check, including wiring,
shutoff valves, and sensors. The results are returned automatically after the check finishes.
High external static pressure 78.4 Pa (8 mm H
2
O)
58.8 Pa
78.4 Pa
33.3%
increase!
Selectable from two types of combinations
Normal type (Space saving type)
High-COP type (Energy saving type)
* Refer to page 26 for outdoor combination details.
* Refer to page 26 for outdoor combination details.
8
10
12
14
16
18
18
2
16
2
36
3
38
3
24
3
26
3
30
3
28
3
34
3
32
3
Total number
of connected
outdoor units
HP
Single unit
Double outdoor units Triple outdoor units
40
3
42
3
46
3
44
3
50
3
48
3
Triple outdoor units
Higher external static pressure has been achieved thanks to the fan grilles and the
dual DC fans that reduce internal pressure loss. Exceeding the previous 58.8 Pa (6
mm H2O) level, Daikin now offers 78.4 Pa
(8 mm H2O) external static pressure by
field setting to meet the requirements for
installation on each floor, often requested
for large-sized buildings.
VRVII
MA series
1211
78.4 Pa
8
10
12
14
16
18
8
1
5
5
1
22
2
24
2
26
2
10
1
12
1
16
1
14
1
20
2
18
1
Total number
of connected
outdoor units
HP
Single unit
Single outdoor units Double outdoor units Double outdoor units
38
3
42
3
40
3
44
3
46
3
48
3
50
3
52
3
54
3
Triple outdoor units
28
2
30
2
34
2
36
2
32
2

Содержание

Скачать