Daikin RXYQ14PAYL [5/36] Hp 8 10 hp 12 14 16 18 hp

Daikin RXYQ14PAYL [5/36] Hp 8 10 hp 12 14 16 18 hp
Large capacities for large-sized buildings Large capacities for large-sized buildings
Main Features
87
Daikin’s indoor unit system offers a large number of connectable indoor units—64! Furthermore, our wide range of
indoor units includes 15 types and 73 models* to meet the needs of customers.
Indoor units
The previous outdoor unit had a maximum output of 48 HP. The VRVIII has a top output of
54 HP! By connecting main units (up to 18 HP each), a high-capacity system (up to 54 HP)
that is compact yet flexible can be achieved.
By providing a range of horse power
levels in 2 HP increments*, Daikin
responds flexibly to customer needs.
* Refer to page 26 for combination details.
Outdoor units
48 HP
54 HP
Ceiling Mounted
Cassette
(Round Flow)
Type
Model Name
Capacity Range
Capacity Index
20
0.8 HP
40
1.6 HP
62.5
2.5 HP
80
3.2 HP
100
4 HP
125
5 HP
140
6 HP
200
8 HP
250
10 HP
50
2 HP
31.25
1.25 HP
25
1 HP
20 40 63 80 100 125 140 200 250503225
Ceiling Mounted
Cassette
(Double Flow)
FXCQ-MVE
Ceiling Mounted
Cassette
(Compact Multi Flow)
FXZQ-MVE
Slim Ceiling
Mounted Duct
Ceiling Mounted
Duct
Ceiling Suspended
Wall Mounted
Floor Standing
Concealed
Floor Standing
Ceiling Mounted
Cassette Corner
FXDQ-NBVE
(with drain pump)
FXDQ-NBVET
(without drain pump)
FXMQ-PVE
FXMQ-MAVE
FXHQ-MAVE
FXAQ-PVE
FXLQ-MAVE
FXNQ-MAVE
FXKQ-MAVE
FXDQ-PBVET
(without drain pump)
FXDQ-PBVE
(with drain pump)
(900/1,100 mm width type)
(700 mm width type)
R-410A VRV system indoor units are not compatible with the R-22 VRV system.Note:
2 HP increments
Offering a higher capacity of up to 54 HP,
responding to the needs of large-sized buildings
* Except for 5 HP
30, 32, 34, 36 HP
38, 40, 42, 44, 46 HP 48, 50, 52, 54 HP
5 HP 8, 10 HP 12, 14, 16, 18 HP
20, 22, 24, 26, 28 HP
VRVII
MA series
New
The latest technology is implemented in the VRVIII system. Surpassing even the VRVII, the VRVIII responds to
more of the needs of our customers that require air-conditioning solutions for large-sized buildings.
Major advances of the VRVIII over the VRVII for large-sized buildings
BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details.Note:
Connection unit series indoor units (50 Hz only)
*
14 types and 70 models for 60 Hz specifications.
Ceiling Suspended
Cassette
Type
Model Name
1.6 HP0.8 HP 1.25 HP1 HP
FXUQ-MAV1
20
4031.2525
BEVQ125MAVE
5 HP
BEVQ100MAVEBEVQ71MAVE
2 HP 4 HP3 HP
50 12510071
Capacity Range
4020 3225 12550 10071
Connection Unit
Capacity Index
FXFQ-PVE
New New New New New New

Содержание

Скачать