3 English
2-1 Combination
The indoor units can be installed in the following range.
• Be sure to connect a dedicated indoor unit. See the catalog for
indoor unit models which can be connected.
• Total capacity/quantity of indoor units
〈
Outdoor unit
〉〈
Total capacity of indoor units
〉〈
Total quantity of indoor units
〉
RXYMQ36PVJU
............................18 ~
50 6 units
RXYMQ48PVJU
............................24 ~ 62 8 units
2-2 Standard operation limit
Normal operation
The figures below assume following operating conditions for indoor and
outdoor units:
Equivalent pipe length .................................................... 25ft. (7.6m)
Level difference ............................................................................0m
Cooling Heating
A Outdoor temperature (°FDB)
B Indoor temperature (°FWB)
C Outdoor temperature (°FWB)
D Indoor temperature (°FDB)
Range for continuous operation
Range for pull down operation
Range for warming up operation
Operation range (performance is not guaranteed)
2-3 Spec list
For operating conditions marked with a *(a)(b) in the table, see “2-2
Standard operation limit”.
2-4 Electrical properties
For operating conditions marked with a *(c) in the table, see “2-2 Stan-
dard operation limit”.
2-5 Standard supplied accessories
Make sure that the accessories shown below are all present.
(The accessories can be found behind the front panel.)
(Refer to figure 1)
1. Accessories
2. Screw for front panel
3. Front panel
2-6 Option accessory
• Refrigerant branching kit
*See “7. PRECAUTIONS ON REFRIGERANT PIPING” for details
on how to connect refrigerant branch kits and how many are
needed.
3. BEFORE INSTALLATION
<Transporting the Unit>
As shown in figure 2, bring the unit slowly. (Take care not to let hands or
things come in contact with rear fins.)
(Refer to figure 2)
1. Air outlet grille
2. Intake hole
3. Corner
4. Outdoor unit
5. Handle
6. Front
7. Rear
8. Always hold the unit by the corners, as holding it by the side
intake holes on the casing may cause them to deform.
Use only accessories and parts which are of the designated specifica-
tion when installing.
Model name
RXYMQ36PVJU RXYMQ48PVJU
RemarksRefrigerant type R410A
Power supply 1 phase 208/230V 60Hz
Cooling performance (MBh) 36 48 * (a)
Heating performance (MBh) 40 54 * (b)
Energy use during cooling (kW) 3.13 4.69 * (a)
Energy use during heating (kW) 3.45 4.45 * (b)
External dimensions
(width × depth × height)
(inch) 52 15/16 × 35 7/16 × 12 5/8
Mass (lb.) 283
Connection
piping
Gas line piping
(inch)
(mm)
φ 5/8”
φ 15.9
φ 5/8”
φ 15.9
Liquid line piping
(inch)
(mm)
φ 3/8”
φ 9.4
φ 3/8”
φ 9.4
6757
77
41
–4
50 70
5
C
50
43
81
A
23
59
82
50
(a)
95
115
60
B
D
(c)
(b)
Model name H/P
RXYMQ36PVJU RXYMQ48PVJU
Remarks
Phase
~
Frequency
(Hz) 60Hz
Voltage
(V) 208/230V
Voltage tolerance range
(%) ±10
Rated current for fuses
(A) 30
Maximum outdoor unit
operating current
(A) 27
* (c)
Name Operation manual Clamp
Quantity 1 6 pcs.
Shape
Name Insulation tube
Others
Quantity 1 pc. 1 pc.
Shape
•
Installation manual
REFNET joint KHRP26M22T
REFNET header KHRP26M22H KHRP26M33H
(Large)
(Small)
01_EN_3PN07193-6F.fm Page 3 Tuesday, September 1, 2009 4:13 PM
Содержание
- Installation manual 1
- System air conditioner 1
- Figure 11 figure 12 3
- Figure 13 3
- Figure 14 3
- Figure 15 3
- Figure 16 3
- Figure 17 3
- Figure 8 3
- Figure 9 figure 10 3
- Figure 18 4
- Figure 19 4
- Figure 20 4
- Figure 21 4
- Figure 22 figure 23 figure 24 figure 25 4
- Figure 26 figure 27 figure 28 4
- Figure 29 figure 30 4
- Contents 5
- English 5
- Installation manual 5
- Safety considerations 5
- English 2 6
- Introduction 6
- 1 combination 7
- 2 standard operation limit 7
- 3 spec list 7
- 4 electrical properties 7
- 5 standard supplied accessories 7
- 6 option accessory 7
- Before installation 7
- English 7
- English 4 8
- Selecting installation site 8
- English 9
- Precautions on installation 9
- 1 wiring connection example for whole system 10
- 2 how to lay the power supply wiring and trans mission wiring 10
- English 6 10
- Field wiring 10
- Ground wire 10
- If small animals might enter the unit block the knock holes with an appropriate material field supply 10
- Insulation tube accessory clamp accessory power supply wiring 10
- Insulation tube accessory clamp accessory transmission wiring 10
- 1 installation tools 11
- 3 how to connect the power supply wiring 11
- 4 transmission wiring connection procedure 11
- Connect wires of the same gauge to both side 11
- Do not connect wires of different gauges 11
- Do not connect wires of the same gauge to one side 11
- English 11
- Insulating sleeve 11
- Precautions on refrigerant piping 11
- Round crimp style terminal electric wire 11
- 2 selecting piping material 12
- 3 protection against contamination when install ing pipes 12
- 4 pipe connection 12
- 5 connecting the refrigerant piping 12
- English 8 12
- 6 heat insulation of piping 13
- English 13
- Refrigerant oil 13
- 7 example of connection 14
- Branch with refnet header 14
- Branch with refnet joint 14
- Branch with refnet joint and refnet header 14
- Connection of 8 indoor units heat pump system 14
- English 10 14
- Example of connection 14
- 8 air tight test and vacuum drying 15
- Direction to open direction to open 15
- English 15
- Make sure that there is no gap 15
- Shutoff valve lid attachment 15
- Silicon sealing pad 15
- Valve lid 15
- 1 before adding refrigerant 16
- 1 power on check operation 16
- 2 checking the refrigerant tank 16
- 3 adding refrigerant 16
- Additional refrigerant charge 16
- English 12 16
- Filling after calculating the amount of refrigerant to add 16
- Post work checks 16
- Stand the tank upside down and charge 16
- Tank with siphon pipe other tanks 16
- Test run 16
- 2 temperature control operation checklist 17
- English 17
- Caution for refrigerant leaks 18
- Direction of the refrigerant flow 18
- English 14 18
- Room where refrigerant leak has occurred outflow of all the refrigerant from the system 18
- English 19
- Pn07193 6f em09a020 20
Похожие устройства
- Daikin RXYMQ48PVJU Руководство по вводу в эксплуатацию
- Daikin RXYMQ48PVJU Сервис мануал
- Daikin RXYMQ48PVJU Инструкция по монтажу
- Cecotec Steel&Toast 2S Инструкция по эксплуатации
- Cecotec Toast&Taste 2S Инструкция по эксплуатации
- Daikin RXYHQ12P8W1B Инструкция по монтажу
- Daikin RXYHQ12P8W1B Технические данные
- Daikin RXYHQ12P8W1B Спецификация
- Daikin RXYHQ12P8W1B Руководство по вводу в эксплуатацию
- Cecotec Toast&Taste 2L Инструкция по эксплуатации
- Daikin RXYHQ16P8W1B Инструкция по монтажу
- Daikin RXYHQ16P8W1B Технические данные
- Daikin RXYHQ16P8W1B Спецификация
- Daikin RXYHQ16P8W1B Руководство по вводу в эксплуатацию
- Daikin RXYHQ18P8W1B Инструкция по монтажу
- Cecotec Steel&Toast 2L Инструкция по эксплуатации
- Daikin RXYHQ18P8W1B Технические данные
- Daikin RXYHQ18P8W1B Спецификация
- Daikin RXYHQ18P8W1B Руководство по вводу в эксплуатацию
- Cecotec Toast&Taste 1L Инструкция по эксплуатации