Daikin RXYQ72PTJU [11/20] 2 program dry operation
![Daikin RXYQ120PTJU [11/20] 2 program dry operation](/views2/1717999/page11/bgb.png)
English 8
NOTE
• For machine protection the system may con-
trol the air flow rate automatically.
• The air flow rate may be adjusted automati-
cally depending on the room temperature or
the fan may stop immediately. This is not a
malfunction.
• It may take sometime for finishing to change
the air flow rate.
This is normal operation.
Press air flow direction adjust button.
Refer to the chapter “6-3 ADJUSTING THE
AIR FLOW DIRECTION” for details.
STOPPING THE SYSTEM (Refer to figure 4)
Press the on/off button once again.
The operation lamp goes off and the system
stops operation.
NOTE
• The fan may keep on running for about
1 minute after the heating operation stops
for removing the heat in the indoor unit.
• Do not turn off the power immediately after
the unit stops.
The system need at least 5 minutes for
residual operation of drain pump device.
Turning off the power immediately will cause
water leak or trouble.
EXPLANATION OF HEATING OPERATION
•
For general heating operation, it may take longer to
reach the set temperature than in cooling operation.
We recommend starting the operation which was
used before using timer operation.
• The following operation is performed in order to
prevent the heating capacity from dropping or
cold air from blowing.
Defrost operation
• In heating operation, freezing of the outside
unit coil increases. Heating capability
decreases and the system goes into defrost
operation.
• The airflow will be set to breeze or stop.
• If stopped, the display of the remote control-
ler shows “ ”.
• Once the airflow is set to breeze or stop, the
air conditioner will return to the previous
state in approximately 5 to 15 minutes.
Hot start
• In order to prevent cold air from blowing out
of an indoor unit at the start of heating oper-
ation, the indoor fan is automatically
stopped. The display of the remote controller
shows
“”
.
• The heating capacity drops as the outside tem-
perature falls. If this happens, use another heat-
ing device together with the unit. (When using the
appliances which produce open fire together, ven-
tilate a room constantly.)
Do not place appliances which produce open fire
in places exposed to the air flow from the unit or
under the unit.
• It takes some time for the room to warm up from
the time the unit is started since the unit is a hot-
air circulatory system to warm the entire room.
• If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend using the cir-
culator (the indoor fan for circulating air). Contact
your dealer for details.
6-2 PROGRAM DRY OPERATION
• The program dry function deprives the room
of moisture while the air conditioner is in inter-
mittent weak cooling operation so that the
room temperature will not become too low.
• The microcomputer automatically controls
the temperature and fan speed, so these
cannot be set using the remote controller.
• This function is not available if the room tem-
perature is 68°F or lower.
• This function does not controls the humidity.
• FXL and FXN type indoor unit can not oper-
ate program dry operation.
FOR SYSTEMS WITHOUT COOL/HEAT SELEC-
TOR (Refer to figure 5)
NOTE
• If “ ” (Cooling operation) is not displayed, refer
to “6-1 COOLING, HEATING, AUTOMATIC AND
FAN ONLY OPERATION”, and set “ ” (Cooling
operation).
Unless the air conditioner is set to “ ” (Cooling
operation), the air conditioner cannot be switched
over to “ ” (program dry operation).
5
6
01_EN_3P215731-1D.fm Page 8 Tuesday, February 5, 2008 6:35 PM
Содержание
- Operation manual 1
- System air conditioner 1
- 1 13 2 3
- _cv_3p215731 1d fm page 3 wednesday february 6 2008 11 34 am 3
- Contents 4
- Safety considerations 4
- Electrical work 6
- Pay attention to operating sound 6
- Place of installation 6
- Design pressure 7
- Dimensions h w d 7
- Drainage through drainpipe 7
- English 4 7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer 7
- Model name 7
- Nominal cooling capacit 7
- Nominal heating capacit 7
- Power supply 7
- Refrigerant 7
- Specifications 7
- English 8
- If your installation has a customized control system ask your daikin dealer for the operation that corre sponds to your system outside units refer to figure 1 8
- Names and functions of parts refer to figure 1 1 outside unit 2 indoor unit 3 remote controller 4 inlet air 5 outlet air 6 bs unit 7 cool heat selector 8 refrigerant piping figure 1 shows system with cool heat selector 8
- On off button press the button and the system will start press the button again and the system will stop 8
- Operation lamp red the lamp lights up during operation 8
- Remote controller and cool heat selector name and function of each switch and display 8
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 8
- This operation manual is for the following system with standard control before initiating operation contact your daikin dealer for the operation that cor responds to your system type and mark 8
- What to do before operation 8
- 1 cooling heating automatic and fan only operation 10
- Operation procedure 10
- Operation range 10
- 2 program dry operation 11
- 3 adjusting the air flow direc tion refer to figure 6 only for dou ble flow multi flow corner ceiling suspended and wall mounted 12
- 4 programming start and stop of the system with timer refer to figure 9 13
- 5 setting the master remote con troller 13
- 6 precautions for group con trol system or two remote controller control system 14
- Optimum operation 14
- 1 at the beginning of the season 15
- 1 the system does not operate 15
- 2 at the end of the season 15
- 2 it stops sometimes 15
- 3 cool heat cannot be changed over 15
- Following symptoms are not air conditioner troubles 15
- Seasonal maintenance 15
- 10 the units can give off odours 16
- 11 the outside unit fan does not rotate 16
- 5 the fan strength does not cor respond to the setting 16
- 6 the fan direction does not cor respond to the setting 16
- 7 white mist comes out of the unit 16
- 8 noise of air conditioners 16
- 9 dust comes out of the unit 16
- Cooling and heating do not work 16
- Fan operation is possible but 16
- 12 the display shows 17
- 13 the compressor or fan in the outside unit does not stop 17
- 14 the inside of outside unit is warm even when the unit has stopped 17
- 15 hot air is emitted even though the unit is stopped 17
- 16 does not cool very well 17
- Trouble shooting 17
- After sales service and warranty 18
- P215731 1d em07a037a 20
Похожие устройства
- Daikin RXYQ72PYDN Сервис мануал
- Daikin RXYQ72PTJU Сервис мануал
- Daikin RXYQ96PYDN Сервис мануал
- Daikin RXYQ96PTJU Сервис мануал
- Daikin RXYQ120PTJU Спецификация
- Daikin RXYQ120PTJU Руководство по вводу в эксплуатацию
- Daikin RXYQ120PTJU Инструкция по эксплуатации
- Daikin RXYQ120PYDN Спецификация
- Daikin RXYQ120PYDN Руководство по вводу в эксплуатацию
- Daikin RXYQ120PYDN Инструкция по эксплуатации
- Daikin RXYQ120PYDN Сервис мануал
- Daikin RXYQ120PTJU Сервис мануал
- Daikin RXYQ72PATJ Спецификация
- Daikin RXYQ72PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ96PATJ Спецификация
- Daikin RXYQ96PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ108PATJ Спецификация
- Daikin RXYQ108PATJ Руководство по вводу в эксплуатацию
- Sinbo SBG 7102A User guide
- Daikin RXYQ72PATJ Инструкция по монтажу