Daikin REYQ120PTJU — правила эксплуатации и установки кондиционеров для безопасности [6/20]
Превью страниц
Страница 6 /
20
![Daikin REYQ192PTJU [6/20] Place of installation](/views2/1717999/page6/bg6.png)
3 English
• Do not turn off the power immediately after
stopping operation.
Always wait at least five minutes before turning off
the power. Otherwise, water leakage and trouble
may occur.
• The appliance is not intended for use by young
children or infirm persons without supervision.
• The remote controller should be installed in
such away that children cannot play with it.
• Consult with installation contractor for clean-
ing the inside of the air conditioner.
Wrong cleaning may make the plastics parts broken
or cause failure of water leakage or electric shock.
• Do not touch the air inlet or aluminum fin of
the air conditioner.
Otherwise, injury may be caused.
• Do not place objects in direct proximity of the
outside unit and do not let leaves and other
debris accumulate around the unit.
Leaves are a hotbed for small animals which can
enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making
contact with electrical parts.
NOTE
• Never press the button of the remote control-
ler with a hard, pointed object.
The remote controller may be damaged.
• Never pull or twist the electric wire of the
remote controller.
It may cause the unit to malfunction.
• Do not place appliances which produce open
fire in places exposed to the air flow from the
unit or under the indoor unit. It may cause
incomplete combustion or deformation of the
unit due to the heat.
• Arrange the drain hose to ensure smooth
drainage. Incomplete drainage may cause
wetting of the building, furniture etc.
• Do not place the controller exposed to direct
sunlight.
The LCD display may get discolored, failing to dis-
play the data.
• Do not wipe the controller operation panel
with benzine, thinner, chemical dustcloth, etc.
The panel may get discolored or the coating peeled
off. If it is heavily dirty, soak a cloth in water-diluted
neutral detergent, squeeze it well and wipe the
panel clean. And wipe it with another dry cloth.
• Dismantling of the unit, treatment of the refrig-
erant, oil and eventual other parts, should be
done in accordance with the relevant local and
national regulations.
[Place of Installation]
• Make sure that the air conditioner is located in
a sufficiently ventilated place not surrounded
by obstacles.
• Do not use the air conditioner in the following
places.
a.
Places with a mist of mineral oil, such as cutting oil.
b. Locations such as coastal areas where there is
a lot of salt in the air.
c. Locations such as hot springs resorts where
there is a lot of sulfur in the air.
d. Locations such as factories where the power
voltage varies a lot.
e. In cars, boats, and other vehicles.
f. Locations such as kitchens where oil may splat-
ter or there is steam in the air.
g. Locations where equipment that produces elec-
tromagnetic waves is found.
h. Places with an acid or alkaline mist.
i. Places where fallen leaves are accumulated or
weeds grow close together.
• Take snow protection measures.
Contact your dealer for the details of snow protec-
tion measures, such as the use of a snow protec-
tion hood.
[Electrical Work]
•
Do not attempt to conduct electrical work or
grounding work unless you are licensed to do so.
Consult with your dealer for electrical work and
grounding work.
• Use a dedicated circuit for the air conditioner.
[Pay Attention to Operating Sound]
• Be sure to use the following places.
a. Places that can sufficiently withstand the weight
of the air conditioner and suppress the operat-
ing sound and vibration of the air conditioner.
b. Places where warm air from the air outlet of the
outside unit or the operating sound of the out-
side unit does not annoy neighbors.
• Make sure that there are no obstacles close to
the outside unit.
Obstacles close to the outside unit may drop the
performance of the outside unit or an increase in
the operating sound of the outside unit.
• Consult your dealer if the air conditioner in
operation generates unusual noise.
01_EN_3P215731-1D.fm Page 3 Tuesday, February 5, 2008 6:35 PM
Содержание
- System air conditioner p.1
- Operation manual p.1
- _cv_3p215731 1d fm page 3 wednesday february 6 2008 11 34 am p.3
- 1 13 2 p.3
- Safety considerations p.4
- Contents p.4
- Place of installation p.6
- Pay attention to operating sound p.6
- Electrical work p.6
- Specifications p.7
- Refrigerant p.7
- Power supply p.7
- Nominal heating capacit p.7
- Nominal cooling capacit p.7
- Model name p.7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer p.7
- English 4 p.7
- Drainage through drainpipe p.7
- Dimensions h w d p.7
- Design pressure p.7
- If your installation has a customized control system ask your daikin dealer for the operation that corre sponds to your system outside units refer to figure 1 p.8
- English p.8
- What to do before operation p.8
- This operation manual is for the following system with standard control before initiating operation contact your daikin dealer for the operation that cor responds to your system type and mark p.8
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 p.8
- Remote controller and cool heat selector name and function of each switch and display p.8
- Operation lamp red the lamp lights up during operation p.8
- On off button press the button and the system will start press the button again and the system will stop p.8
- Names and functions of parts refer to figure 1 1 outside unit 2 indoor unit 3 remote controller 4 inlet air 5 outlet air 6 bs unit 7 cool heat selector 8 refrigerant piping figure 1 shows system with cool heat selector p.8
- Operation range p.10
- Operation procedure p.10
- 1 cooling heating automatic and fan only operation p.10
- 2 program dry operation p.11
- 3 adjusting the air flow direc tion refer to figure 6 only for dou ble flow multi flow corner ceiling suspended and wall mounted p.12
- 5 setting the master remote con troller p.13
- 4 programming start and stop of the system with timer refer to figure 9 p.13
- Optimum operation p.14
- 6 precautions for group con trol system or two remote controller control system p.14
- Seasonal maintenance p.15
- Following symptoms are not air conditioner troubles p.15
- 3 cool heat cannot be changed over p.15
- 2 it stops sometimes p.15
- 2 at the end of the season p.15
- 1 the system does not operate p.15
- 1 at the beginning of the season p.15
- Fan operation is possible but p.16
- Cooling and heating do not work p.16
- 9 dust comes out of the unit p.16
- 8 noise of air conditioners p.16
- 7 white mist comes out of the unit p.16
- 6 the fan direction does not cor respond to the setting p.16
- 5 the fan strength does not cor respond to the setting p.16
- 11 the outside unit fan does not rotate p.16
- 10 the units can give off odours p.16
- Trouble shooting p.17
- 16 does not cool very well p.17
- 15 hot air is emitted even though the unit is stopped p.17
- 14 the inside of outside unit is warm even when the unit has stopped p.17
- 13 the compressor or fan in the outside unit does not stop p.17
- 12 the display shows p.17
- After sales service and warranty p.18
- P215731 1d em07a037a p.20
Похожие устройства
-
Daikin FXSQ125A2VEBРуководство по запуску и установке -
Daikin FXSQ100A2VEBРуководство по инсталляции -
Daikin FXSQ80A2VEBИнструкция по монтажу -
Daikin FXSQ63A2VEBРуководство по монтажу -
Daikin FXSQ50A2VEBИнструкция по монтажу -
Daikin FXSQ40A2VEBИнструкция по монтажу -
Daikin FXSQ32A2VEBИнструкция по установке -
Daikin FXSQ25A2VEBИнструкция по установке -
Daikin FXSQ20A2VEBРуководство по инсталляции -
Daikin FXSQ15A2VEBИнструкция по монтажу -
Daikin RXYQ54PYLСервис мануал -
Daikin RXYQ52PYLСервис мануал
Узнайте важные рекомендации по безопасной эксплуатации и установке кондиционеров. Избегайте повреждений и обеспечьте долговечность вашего устройства.