05
ET550-HG/ET650-HG/ET750-HG(V1.0)
When OVP ,OPP ,OCP or short protection is triggered, the main outputs will be latched off.
The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto
recovery when fault condition removed.
ET550-HG/ET650-HG/ET750-HG (V1.1)
When OVP ,OPP ,OCP,OTP or short protection is triggered, the main outputs will be latched off.
The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto
recovery when fault condition removed.
2.2 HOLD-UP TIME
10msec (minimum) at 80% of full load at 230Vac input.
2.3 POWER GOOD DELAY
100-500 msec.
2.4 POWER FAIL DELAY
>1 msec.
2.5 TURN-ON DELAY TIME
2000 msec max.At nominal line full load.
2.6 TRANSIENT OVERSHOOT
DC output transient step sizes as below table:
2.7 RISE TIME
20ms max at full load.
Load-changing repetition rate of 10m seconds.
Load slew rated 1.0A/uS and capacitive load as below :
3.0 PROTECTION:
Output voltage +5V +3.3V +12V
Max. step size 30% 30% 60%
+5V +3.3V +12V -12V +5Vsb
10000uF 10000uF 10000uF 470uF 3300uF
3.1 OVER VOLTAGE PROTECTION
+3.3V output 4.5 Vmax.
+5.0V output 7.0 Vmax.
+12.0V output 15.6 Vmax.
3.2 SHORT PROTECTION
All output to GND.