06
5.1 No Load Start
5. Start Stability
Frequency
5-55-10 Hz
Duration
30 minutes
Amplitude
0.35 mm
Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will auto-recovery.
4.2.4 Short Circuit Protection
Current protection should be designed to limit the current to operate within safe operating conditions.
Over current protection schemes where only the voltage output that experiences the over current event
is shut off may be adequate to maintain safe operation of the power supply and the system; however,
damage to the motherboard or other system components may occur. The recommended over current
protection scheme is for the power supply to latch into the shutdown state. The setting of over current
protection for each output rail is as following.
When power is applied to ST75F-PT, ST65F-PT, ST55F-PT with no load connected or under minimum
load connected, neither damage to power supply nor hazards to users will occur.
6.1 Temperature and Humidity
6. Environments
6.1.1 Operating
6.2 Altitude
The power supply can operate normally at any altitude between 0 to 10000 feet.
6.3 Vibration and Shock
Sweep and resonance search for each of X,Y,Z, axis at the sweep.
RATE of 1/OCTAVE/Min.
Temperature 0 to 40C
Relative Humidity 20 to 90 %
5.2 Cold Start
The power supply shall operate properly when first applied at normal input voltage and or so maximum
load after 4 hours storage in 0 environment.
4.2.5 Over-Current Protection
o
6.1.2 Storage
Temperature -40 to 70C
Relative Humidity 20 to 95 % noncondensing