• Automatic Changeover to Efficient Operation Patterns
Operation automatically switches to the optimum pattern to suit prevailing conditions
2. DESIGN FLEXIBILITY
• Outdoor Operation Temperature down to -15°C
If the outdoor air suction temperature falls below -10°C, the unit switches to intermittent
operation to prevent freezing of the heat exchanger element and dew condensation within the
unit.
Intermittent operation = a thermistor (standard equipment) within the unit detects the outdoor
air temperature. Unit operation varies according to the detected temperature.
• Slim Design
The slim design of the HRV unit enables it to be mounted in narrow ceiling voids and irregularly
shaped spaces.
design flexibility
p. 7
2
Cooling In between (bypass ventilation) Heating
Automatic
changeover
Automatic
changeover
Exhaust fan Damper
Heat exchanger element
(heat recovery)
Heat exchanger element
(heat recovery)
DX coil (cooling)
Air supply fan
DX coil (heating)
Humidifying
EA
OA
EA
OA
RA
SA
RA
SA
EA
OA
RA
SA
269mm VAM250FA
• Installation under the floor of a small building • Installation under a beam • Installation in an irregular space
348mm
375 EPCE05-44B UK artwork 26/6/06 12:25 pm Page 7
Содержание
- Eatures 3
- Ntroduction 3
- Pecifications 3
- Ptions 3
- Table of contents 3
- Ystems 3
- Daikin airconditioning uk ltd 4
- Daikin europe n v 4
- Environmental consciousness 4
- Features 6
- Fficiency 6
- Ii general hrv vam vkm 6
- Automatic changeover to efficient operation patterns operation automatically switches to the optimum pattern to suit prevailing conditions 7
- Lexibility 7
- Outdoor operation temperature down to 15 c if the outdoor air suction temperature falls below 10 c the unit switches to intermittent operation to prevent freezing of the heat exchanger element and dew condensation within the unit intermittent operation a thermistor standard equipment within the unit detects the outdoor air temperature unit operation varies according to the detected temperature 7
- Slim design the slim design of the hrv unit enables it to be mounted in narrow ceiling voids and irregularly shaped spaces 7
- Daikin units 8
- Epce05 44b uk artwork 26 6 06 12 26 pm page 8 8
- Quiet operation sound pressure levels are remarkable low at 20 dba vam150fa 8
- Simple design and construction the unit can be installed either horizontally or upside down in accordance with the conditions of the location a 450mm square inspection hatch enables maintenance and heat exchange element replacement to be performed with ease 8
- Dust prevention prevents dust from falling thanks to directly mounted ducts 9
- Filter cleaning a signal on the remote control indicates when the air filter needs cleaning 9
- Fresh up operation the user can select between 2 fresh up modes via the remote control 9
- Fficiency 10
- Iii vkm features 10
- 5 0 5 10 15 20 25 30 35 40 11
- Efficient outdoor air introduction with heat exchanger and cooling heating operation indoor unit with outdoor air treatment the temperature can be brought close to room temperature with minimal cooling capacity through the use of outdoor air 11
- High static pressure modifications to the fan including the use of multiple arc blades a thinner scroll and optimized fan scroll angle help to boost efficiency dramatically higher static pressure is achieved due to improved fan performance this reduces limitations on unit location and allows more flexibility in duct design 11
- Indoor unit connectability the indoor unit is connectable up to 130 of outdoor unit capacity 11
- Lexibility 11
- Epce05 44b uk artwork 26 6 06 12 26 pm page 12 12
- Iv line up 12
- Vam fa ventilation 12
- Vkm g ventilation and dx coil 12
- Vkm gm ventilation dx coil and humidifier 12
- Brc1d52 13
- Brc301b61 13
- V control systems 13
- 1 count vkm unit as two air conditioners for details see table 1 on page 15 14
- A variety of control systems can be controlled using only the brc1d52 14
- Control using 2 remote controls allows control of air conditioning and hrv units from two locations by connecting two air conditioner remote controls group control is possible 14
- Epce05 44b uk artwork 26 6 06 12 26 pm page 14 14
- Group control one air conditioner remote control simultaneously controls up to 16 air conditioning and hrv units 14
- I n d i v i d u a l c o n t r o l s y s t e m s 14
- Long distance remote control remote operation control from a distant control room for example is possible thanks to wiring of up to 500 m 2 remote control control possible 14
- A i r c o n d i t i o n i n g i n t e r l o c k e d c o n t r o l v r v s k y a i r s y s t e m 15
- I n d e p e n d e n t o p e r at i o n 15
- I n d e p e n d e n t o p e r at i o n s y s t e m 15
- M u lt i p l e g r o u p s i n t e r l o c k e d o p e r at i o n s y s t e m 15
- Necessary accessories 15
- S i m u lta n e o u s o p e r at i o n o f m u lt i p l e u n i t s 15
- S ta n d a r d s y s t e m 15
- System characteristics 15
- System construction 15
- Dcs301b51 16
- Dcs302c51 16
- Dst301b51 16
- Entralise 16
- Ystems 16
- A i r c o n d i t i o n i n g i n t e r l o c k e d c e n t r a l i s e d c o n t r o l s y s t e m c o m b i n a t i o n w i t h o t h e r t y p e s o f a i r c o n d i t i o n e r s 17
- B at c h i n d i v i d u a l c o n t r o l s y s t e m 17
- Necessary accessories 17
- System characteristics 17
- System construction 17
- Z o n e c o n t r o l s y s t e m 17
- Epce05 44b uk artwork 26 6 06 12 26 pm page 18 18
- Vam fa 18
- Ventilation 18
- Vi specifications 18
- Epce05 44b uk artwork 26 6 06 12 26 pm page 19 19
- Ventilation dx coil humidifier 19
- Vkm gm 19
- Epce05 44b uk artwork 26 6 06 12 26 pm page 20 20
- Ventilation dx coil 20
- Epce05 44b uk artwork 26 6 06 12 26 pm page 21 21
- Vii options 21
- Board adapter for heater control ki 22
- Brp4a50 22
- Notes when installing examine fully installation location and specification for using the electric heater based on the standards and regulations of each country supply the electric heater and safety production devices such as a relay and a thermostat etc which meet the on site standards and regulations of each country use a non flammable connecting duct to the electric heater be sure to allow 2m or more between the electric heater and hrv for safety for the hrv units use a different power supply from that of the electric heater and install a circuit breaker for each of them 22
- When the installation of an electric heater is required in a cold region this adapter with an internal timer function eliminates the complicated timer connecting work necessary with conventional heaters 22
- Epce05 44b uk artwork 26 6 06 12 26 pm page 23 23
- Daikin airconditioning uk limited 24
- Epce05 44b uk artwork 26 6 06 12 26 pm page 24 24
- Head office 24
- Tel 0845 6419000 fax 0845 6419109 24
- The heights brooklands weybridge surrey kt13 0ny 24
- The present catalogue is drawn up by way of information only and does not constitute an offer binding upon daikin europe n v daikin europe n v has compiled the content of this catalogue to the best of its knowledge no express or implied warranty is given for the completeness accuracy reliability or fitness for particular purpose of its content and the products and services presented therein specifications are subject to change without prior notice daikin europe n v explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this catalogue all content is copyrighted by daikin europe n v 24
- Ukepce05 44b 05 6 swim la movida printed on elemental chlorine free paper printed by portishead press 24
- Www daikin co uk 24
Похожие устройства
- Daikin VAM1500FA Технические данные
- Daikin VAM2000FA Размерные чертежи
- Daikin VAM2000FA Инструкция по монтажу
- Daikin VAM2000FA Инструкция по эксплуатации
- Daikin VAM2000FA Технические данные
- Daikin VAM350FB Инструкция по монтажу
- Daikin VAM350FB Технические данные
- Daikin VAM500FB Инструкция по монтажу
- Daikin VAM500FB Технические данные
- Daikin VAM650FB Инструкция по монтажу
- Daikin VAM650FB Технические данные
- Daikin VAM800FB Технические данные
- Daikin VAM800FB Инструкция по монтажу
- Daikin VAM1000FB Инструкция по монтажу
- Daikin VAM1000FB Технические данные
- Daikin VAM1500FB Инструкция по монтажу
- Daikin VAM1500FB Технические данные
- Daikin VAM2000FB Инструкция по монтажу
- Daikin VAM2000FB Технические данные
- Daikin VAM150FJVE Инструкция по эксплуатации