SilverStone OP650-P [8/12] Agency requirements
![SilverStone SST-OP650-P [8/12] Agency requirements](/views2/1720101/page8/bg8.png)
07
5.2 Humidity
6. Agency Requirements
6.1 Safety Certification.
6.2 AC Input Leakage Current
IInput leakage current from line to ground will be less than 3.5mA rms. Measurement will be
made at 240 VAC and 60Hz.
7. Reliability
7.1 Mean Time Between Failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis
method of MIL217F or Bell core RPP. The calculated MTBF of the power supply
shall be greater than 100,000 hours under the following conditions:
Full rated load
120V AC input
Ground Benign
25°C
Table 16 –Safety Certification
UL 60950-1 2000Edition, IEC60950-1, 3
rd
Edition EU
Low Voltage Directive (73/23/EEC) (CB) TUV, CCC
FCC Part15 ( Radiated & Conducted Emissions ) CISPR
22,3
rd
Edition / EN55022: 1998 + A1: 2000)
EN61000-3-2:2000
EN61000-3-3: 1995 + A1: 2002
EN55024: 1998 + A1: 2001 and A2: 2003
-IEC 61000-4-2
-IEC 61000-4-3
-IEC 61000-4-4
-IEC 61000-4-5
-IEC 61000-4-6
-IEC 61000-4-11
Product Safety:
RFI Emission:
PFC Harmonic:
Flicker:
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
-RF Conducted
-Voltage Dips and Interruptions
Operating Humidity Range:
20% ~ 90%RH non-condensing
Non-Operating Humidity Range: 5% ~ 95%RH non-condensing
Содержание
- Op650 p 1
- Op650 p manual 封面 pdf 1
- Series 1
- Single rail stepping up to a higher gear 1
- Op650 p manual 01 pdf 2
- Specification 2
- Ac input specifications 3
- General 3
- Op650 p manual 02 pdf 3
- Dc output specification 4
- Dc voltage regulation ripple and noise 4
- Note 1 maximum continuous total dc output power should not exceed 650 w 4
- Op650 p manual 03 pdf 4
- Output current loading 4
- Ripple and noise shall be measured using the following methods 4
- Timing requirements 4
- Op650 p manual 04 pdf 5
- Table 10 output voltage timing 5
- Table 11 turn on off timing 5
- 5vsb standby 6
- Ac input 6
- Ac off ac on 6
- Efficiency 6
- Op650 p manual 05 pdf 6
- Remote on off control pson 6
- Environmental requirements 7
- Op650 p manual 06 pdf 7
- Protection 7
- Ac input leakage current 8
- Agency requirements 8
- Humidity 8
- Mean time between failures mtbf the mtbf of the power supply shall be calculated utilizing the part stress analysis method of mil217f or bell core rpp the calculated mtbf of the power supply shall be greater than 100 000 hours under the following conditions full rated load 120v ac input ground benign 25 c 8
- Non operating humidity range 5 95 rh non condensing 8
- Op650 p manual 07 pdf 8
- Operating humidity range 20 90 rh non condensing 8
- Reliability 8
- Safety certification 8
- Mechanical requirements 9
- Op650 p manual 08 pdf 9
- Op650 p manual 09 pdf 10
- Pin pci express connector 10
- Pin peripheral connector hdd 4pin floppy connector fdd 10
- Sata connector 10
- Op650 p manual 10 pdf 11
- Op650 p manual 封底 pdf 12
Похожие устройства
- SilverStone OP650-P инструкция по установке
- SilverStone SST-OP650-P Инструкция по эксплуатации
- SilverStone SST-OP650-P инструкция по установке
- SilverStone OP700 Инструкция по эксплуатации
- SilverStone OP700 инструкция по установке
- SilverStone SST-OP700 Инструкция по эксплуатации
- SilverStone SST-OP700 инструкция по установке
- SilverStone OP750 Инструкция по эксплуатации
- SilverStone OP750 инструкция по установке
- SilverStone SST-OP750 Инструкция по эксплуатации
- SilverStone SST-OP750 инструкция по установке
- SilverStone OP750-P Инструкция по эксплуатации
- SilverStone OP750-P инструкция по установке
- SilverStone SST-OP750-P Инструкция по эксплуатации
- SilverStone SST-OP750-P инструкция по установке
- SilverStone OP800 Инструкция по эксплуатации
- SilverStone OP800 инструкция по установке
- SilverStone SST-OP800 Инструкция по эксплуатации
- SilverStone SST-OP800 инструкция по установке
- SilverStone OP850 Инструкция по эксплуатации