SilverStone SST-ST40F(original) [5/12] St350 manual 05

SilverStone SST-ST365 [5/12] St350 manual 05
04
3.5.3 Short-Current Protection
A short circuit at any output shall cause no damage to the power supply nor blow the
primary fuse. The supply may shut down in the event of a short circuit and require
power-on restart. A short circuit consists of application of a test resistance of less
than 0.05 ohms at each output with maximum load on all outputs.
3.6 OUTPUT RISETIME
The cold-start enable output voltage risetime of all outputs shall be measured with
maximum load on all outputs.
risetime : +3.3V 20mS (maximum)
(10-95%) +5V 20mS (maximum)
+12 V1DC 20mS (maximum)
+12 V2DC 20mS (maximum)
-12 V 20mS (maximum)
+5Vsb 20mS (maximum)
3.5 PROTECTION
3.5.1 Over-voltage protection
In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the power supply
shall
shutdown and require remote control or remove the AC mains input to reset the system.
+5V : 6.5V (maximum)
+3.3V : 4.6V (maximum)
+12V1DC : 15.5V (maximum)
+12V2DC : 15.5V (maximum)
3.5.2 Over-LOAD protection
There shall be protection from an output over-current event. The supply may shutdown
form such an event and require power-on restart. Testing consists of application of the
listed over-current value with maximum load on all other outputs.
Over-current test values: (maximum load)
+3.3V : 75A maximum
+5V : 56A maximum
+12V1DC : 25A maximum
+12V2DC : 30A maximum
STRIDER ST350