4.3 Over Current Protection
The power supply should contain the OCP function on each hot swap module.
The power supply should be shut down in a latch off mode while the respective output current
exceeds the limit as shown in Table 8. When the latch has been cleared by toggling the PSON#
single or cycling the AC input power. The power supply module should not be damaged in this
condition.
4.4 Short Circuit Protection
The power supply shall shut down in a latch off mode when the output voltage is short circuit.
Table 7 –Over Voltage protection
Table 8 –Over Current protection
07
Voltage
+5V
+3.3V
+12V
5VSB
Minimum
+5.7V
+3.9V
+13.3V
+5.7V
Maximum
+6.5V
+4.5V
+14.5V
+6.5V
Shutdown Mode
Latch Off
Latch Off
Latch Off
Auto recovery
Voltage
+5V
+3.3V
+12V
Operating Temperature Range:
Non-Operating Temperature Range:
0°C ~ 40°C (32°F~ 104°F)
-40°C ~ 70°C (-40°F~ 158°F)
Minimum
110%
110%
110%
Maximum
160%
160%
160%
Shutdown Mode
Latch Off
Latch Off
Latch Off
5. Environmental Requirements
5.1 Temperature
Содержание
- St46gf 1
- 封面 1
- Ac input characteristics 2
- General 2
- Silverstone gemini st46gf mini redundant power supply with active pfc 460w 460w 2
- Specification 2
- St46gf 3
- Dc output specification 4
- St46gf 5
- Dc output specification 6
- Figure 2 turn on off timing 6
- Output current loading 6
- Table 5 turn on off timing 6
- The following table defines power and current rating the power supply shall meet both static and dynamic voltage regulation requirements for minimum load condition 6
- Protection 7
- St46gf 7
- Environmental requirements 8
- Agency requirements 9
- Redundant power supply function 9
- St46gf 9
- Physical characteristics size 11
- Reliability 11
- St46gf 11
- 封底 12
Похожие устройства
- SilverStone SST-ST46GF(V3) инструкция по установке
- SilverStone ST50EF Инструкция по эксплуатации
- SilverStone ST50EF инструкция по установке
- SilverStone SST-ST50EF Инструкция по эксплуатации
- SilverStone SST-ST50EF инструкция по установке
- SilverStone ST50EF-PLUS Инструкция по эксплуатации
- SilverStone ST50EF-PLUS инструкция по установке
- SilverStone SST-ST50EF-PLUS Инструкция по эксплуатации
- SilverStone SST-ST50EF-PLUS инструкция по установке
- Daikin FTXTM30M2V1B Технические данные
- Daikin FTXTM30M2V1B Инструкция по монтажу
- Daikin FTXTM30M2V1B Инструкция по эксплуатации
- Daikin FTXTM40M2V1B Технические данные
- Daikin FTXTM40M2V1B Руководство по эксплуатации
- Daikin FTXTM40M2V1B Инструкция по эксплуатации
- Daikin BRP069A45 Технические данные
- Daikin BRP069A45 Руководство по эксплуатации
- Daikin BRP069A45 Инструкция по эксплуатации
- SilverStone ST50EF-PLUS-SC Инструкция по эксплуатации
- SilverStone ST50EF-PLUS-SC инструкция по установке