Daikin FTX50GV1B [8/15] 1 dimensional drawings
![Daikin FTX60GV1B [8/15] 1 dimensional drawings](/views2/1720418/page8/bg8.png)
• Indoor Unit • FTX-GV
4
• Split - Sky Air • FTX-GV
6
4 Dimensional drawings
4 - 1 Dimensional Drawings
FTX50-60GV
3D055875A
The mark
Left
Rear Rear
Right
(Space for
maintenance)
Min. 50
Model name
plate
Terminal block
with earth
terminal (inside)
Wall hole for
embedded piping
ø 80 hole
Infrared
remote control
Signal
transmitter
Front grille fixing screws
(inside)
Flaps
Operation lamp
Signal receiver
Indoor unit on/off
switch
Room temp. thermistor
(inside)
Intelligent eye sensor
Timer lamp
Home leave lamp
Horizontal blade
(automatic)
Cooling Heating Dry
Vertical blade (automatic)
Fan
Wall hole
ø 80 hole
STANDARD LOCATIONS OF WALL HOLES
BLADE ANGELS
Gas pipe ø12.7 Cut
(the lenght of pipe outside
the unit: about 430)
Liquid pipe ø6.4 Cut
(the lenght of pipe outside the
unit: about 480)
Drain hose for VP13
(connection part
I.D. 14.0, O.D. 18.0)
(The hose length
of outside the unit:
about 530)
Min. 50
(Space for
maintenance)
Min. 30
(Space for
performance)
REQUIRED SPACE
Air flow (indoor)
(For performance and maintenance)
shows piping direction
(Including
installation plate)
FTX71GV
3D055876A
The mark
Left
Rear Rear
Right
(Space for
maintenance)
Min. 50
Model name
plate
(Including
installation plate)
Terminal block
with earth
terminal (inside)
Wall hole for
embedded piping
ø 80 hole
Infrared
remote control
Signal
transmitter
Front grille fixing screws
(inside)
Flaps
Operation lamp
Signal receiver
Indoor unit on/off
switch
Room temp. thermistor
(inside)
Intelligent eye sensor
Timer lamp
Home leave lamp
Horizontal blade
(automatic)
Cooling Heating Dry
Vertical blade (automatic)
Fan
Wall hole
ø 80 hole
STANDARD LOCATIONS OF WALL HOLES
BLADE ANGELS
Gas pipe ø15.9 Cut
(the lenght of pipe outside
the unit: about 430)
Liquid pipe ø6.4 Cut
(the lenght of pipe outside the
unit: about 480)
Drain hose for VP13
(connection part
I.D. 14.0, O.D. 18.0)
(The hose length
of outside the unit:
about 530)
Min. 50
(Space for
maintenance)
Min. 30
(Space for
performance)
REQUIRED SPACE
Air flow (indoor)
(For performance and maintenance)
shows piping direction
Содержание
- Air conditioning 1
- Ftx gv 1
- Technical data 1
- Table of contents ftx gv 3
- Features 4
- Indoor unit ftx gv 4
- Split sky air ftx gv 2 4
- Wall mounted unit providing high efficiency and comfort 4
- 1 technical specifications 5
- Specifications 5
- 1 technical specifications 6
- 2 electrical specifications 6
- Indoor unit ftx gv 6
- Specifications 6
- Split sky air ftx gv 4 6
- 1 options 7
- Options 7
- 1 dimensional drawings 8
- Dimensional drawings 8
- Indoor unit ftx gv 8
- Split sky air ftx gv 6 8
- 1 centre of gravity 9
- Centre of gravity 9
- 1 piping diagrams 10
- Piping diagrams 10
- 1 wiring diagrams single phase 11
- Wiring diagrams 11
- 1 sound pressure spectrum 12
- Indoor unit ftx gv 12
- Sound data 12
- Split sky air ftx gv 10 12
- 1 sound pressure spectrum 13
- Sound data 13
- Barcode 15
- Eeden15 100 05 15 copyright daikin the present publication supersedes eeden14 100 15
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu be 0412 120 336 rpr oostende 15
Похожие устройства
- Daikin FTX60GV1B Технические данные
- Daikin FTX71GV1B Технические данные
- Daikin FTXS50FV1B Технические данные
- Daikin FTXS50FV1B Сервис мануал
- Daikin FTXS50FV1B Инструкция по монтажу
- Daikin FTXS50FV1B Инструкция по эксплуатации
- Daikin FTXS60FV1B Технические данные
- Daikin FTXS60FV1B Сервис мануал
- Daikin FTXS60FV1B Инструкция по монтажу
- Daikin FTXS60FV1B Инструкция по эксплуатации
- Daikin FTXS71FV1B Технические данные
- Daikin FTXS71FV1B Сервис мануал
- Daikin FTXS71FV1B Инструкция по монтажу
- Daikin FTXS71FV1B Инструкция по эксплуатации
- Kawai CA99B Руководство по функциям MIDI
- Kawai CA99B Руководство пользователя
- Kawai CA99EP Руководство по функциям MIDI
- Kawai CA99EP Руководство пользователя
- Kawai CA99R Руководство по функциям MIDI
- Kawai CA99R Руководство пользователя
Скачать
Случайные обсуждения