Daikin FLXS35BAVMB [9/15] Indoor unit installation
![Daikin FLXS50BVMB [9/15] Indoor unit installation](/views2/1720624/page9/bg9.png)
7 ■English
Indoor Unit Installation
Wall Mounting
3.
Installation.
• Install the indoor unit on the wall according to the installation drawings.
1) Hang the indoor unit on the hooks of mounting plate. (2 places)
2) Fix the three holes in the lower portion of the indoor unit with M4 × 25L screws.
• Work should be performed to match the direction of the piping, as the extension auxiliary pipe ( , supplied) and installa-
tion methods vary depending on the direction the piping is brought out.
1) Select the extension auxiliary pipe in accordance with the
direction of the piping. (This should be done without the
included piping for wall-mounted right-back piping and
ceiling-mounted upper right-side piping.)
2) Attach the heat insulation tube to the extension auxil-
iary pipe. (Make sure there are no gaps.)
3) Attach the extension auxiliary pipe to the product.
A
Mounting plateA
Electric component cover
(2 claws)
Front grille
M4 × 25L
J Side cover
(6 claws)
J Side cover
less than 1
A Mounting plate
Indoor unit
hook portion
Condition for installation
M
Bottom-
right piping
Right side
piping
2)
3)
N
01_EN_3P171284-2D.fm Page 7 Monday, August 23, 2010 2:33 PM
Содержание
- Flxs25bvmb flks25bvmb flxs35bvmb flks35bvmb flxs50bvmb flks50bvmb flxs60bvmb flks60bvmb flx25bvmb flk25bvmb flx35bvmb flk35bvmb flxs25bavmb flks25bavmb flxs35bavmb flks35bavmb flxs50bavmb flks50bavmb flxs60bavmb flks60bavmb 1
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries ltd 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 e 2
- Sb64526 4 2
- Shinri sada manager quality control department 1st of nov 2008 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- English 2 4
- Indoor unit 4
- Wireless remote controller 4
- Before installing the indoor unit 5
- English 5
- How to the different addresses 5
- In case of ceiling suspended use 5
- Installation tips 5
- Perform the following before installing the indoor unit 5
- Air filters 6
- B photocatalytic deodorizing filter c air purifying filter 6
- B photocatalytic deodorizing filter or c air purifying filter 6
- English 4 6
- Hold the recessed parts of the frame and unhook the four claws 6
- Indoor unit installation drawings 6
- Wrap the insulation pipe with the finishing tape from bottom to top 6
- Ceiling mounting 7
- English 7
- Indoor unit installation drawings 7
- Wall mounting 7
- Ceiling mounting 8
- English 6 8
- Indoor unit installation 8
- Installing indoor unit 8
- Installing the suspension bolt 8
- English 9
- Indoor unit installation 9
- Installation 9
- Wall mounting 9
- Commonality between ceiling mounting and wall mounting 10
- English 8 10
- Installing indoor unit 10
- Warning 10
- Wiring 10
- Drain piping 11
- English 11
- Indoor unit installation 11
- Insulation of refrigerant pipes 11
- Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches 12
- Caution 12
- Cut the pipe end with a pipe cutter 2 remove burrs with the cut surface facing down ward so that the chips do not enter the pipe 3 put the flare nut on the pipe 4 flare the pipe 5 check that the flaring is properly made 12
- Do not use mineral oil on flared part 2 prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 never use piping which has been used for previous installations only use parts which are delivered with the unit 4 do never install a drier to this r410a unit in order to guarantee its lifetime 5 the drying material may dissolve and damage the system 6 incomplete flaring may cause refrigerant gas leakage 12
- Flaring the pipe end 12
- Protect the open end of the pipe against dust and moisture 2 all pipe bends should be as gentle as possible use a pipe bender for bending 12
- Refrigerant piping 12
- Refrigerant piping work 12
- Use the flare nut fixed to the main unit to prevent cracking of the flare nut by aged deterioration 2 to prevent gas leakage apply refrigeration oil only to the inner surface of the flare use refrigeration oil for r410a 3 use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage 12
- Warning 12
- 2 selection of copper and heat insulation materials 13
- English 13
- Refrigerant piping work 13
- Test items 14
- Trial operation and testing 14
- Trial operation from remote controller 14
- P171284 2d m02b074j 15
Похожие устройства
- Daikin FLXS35BAVMB Инструкция по эксплуатации
- Daikin FLXS35BAVMB Сервис мануал
- Daikin FLXS50BAVMB Технические данные
- Daikin FLXS50BAVMB Инструкция по монтажу
- Daikin FLXS50BAVMB Инструкция по эксплуатации
- Daikin FLXS60BAVMB Технические данные
- Daikin FLXS60BAVMB Инструкция по монтажу
- Daikin FLXS60BAVMB Инструкция по эксплуатации
- Daikin FLXS60BAVMB Сервис мануал
- Daikin FLXS50BAVMB Сервис мануал
- MSI GS65 Stealth 9SD Руководство пользователя
- MSI GE66 Raider 10UG-418RU Руководство пользователя
- MSI GE66 Raider 10UH-416RU Руководство пользователя
- MSI GE66 Raider 10UH-417RU Руководство пользователя
- MSI Stealth 15M A11SEK-205RU Руководство пользователя
- MSI Stealth 15M A11UEK-083RU Руководство пользователя
- MSI GS66 Stealth 10UG-273RU Руководство пользователя
- MSI GS66 Stealth 10UH-420RU Руководство пользователя
- MSI GS66 Stealth 10UG-452RU Руководство пользователя
- MSI GS66 Stealth 10UG-453RU Руководство пользователя