SilverStone ST70EF [5/12] Element st70ef

SilverStone SST-ST70F [5/12] Element st70ef
ELEMENT ST70EF
04
ELEMENT ST70EF
+3.3V
0.8A
1A
0.8A
1A
1A
1A
1A
1.5A
24A
24A
Condition_3
Condition_4
LOAD
Condition_1
Condition_2
Condition_5
Condition_6
Condition_7
Condition_8
Condition_9
Condition_10
+5V
1A
0.5A
0.5A
1A
2A
2A
15A
20A
10A
0.5A
12V1
1A
0A
0.5A
1A
10A
5.5A
3A
8A
8A
1A
12V2
1A
0A
0.5A
1A
10A
5.5A
3A
8A
8A
1A
12V3
1A
0.9A
0.5A
1A
10A
15A
3A
8A
10A
1A
12V4
1A
0.1A
0.5A
1A
5.5A
15A
3A
8A
10A
1A
12V5
1A
0.1A
0.5A
1A
5.5A
15A
3A
8A
8A
1A
-12V
0.1A
0A
0A
0.5A
0.1A
0.1A
0.1A
0.1A
0.5A
0A
+5VSB
3A
0.1A
3A
0.1A
0.1A
0.1A
0.1A
0.1A
3A
0.1A
4.3. HOLD-UP TIME (@ Full Load of Table 1)
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
The output voltage will remain within specification, in the event that the input power is removed or
interrupted. The interruption may occur at any point in the AC voltage cycle. The power good signal
shall remain high during this test.
4.4.OUTPUT RISE TIME
(10% TO 90% OF FINAL OUTPUT VALUE, @FULL LOAD)
115V-rms or 230V-rms + 5Vdc/3.3Vdc : 20ms Maximum
115V-rms or 230V-rms + 12Vdc : 20ms Maximum
115V-rms or 230V-rms + 5Vsb : 25ms Maximum
115V-rms or 230V-rms - 12Vdc : 20ms Maximum
4.5.OVER VOLTAGE PROTECTION
12VDC
Voltage Source
+3.3V
+5V
Protection Point
3.76V-4.8V
5.6V-7.0V
13.5V-16.5V
4.2. LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits DC include DC Output ripple& noise.

Содержание

Скачать