SilverStone SST-ST70EF [6/12] Over current protection

SilverStone SST-ST70EF [6/12] Over current protection
05
4.6.OVER-CURRENT PROTECTION
12V1
Output Voltage
+3.3V
+5V
Max. overcurrent limit
35A
40A
30A
12V4
12V2
12V3
30A
30A
30A
12V5 30A
4.7.SHORT CIRCUIT PROTECTION
Output short circuit is defined to be a short circuit load of less than 0.1 ohm.
In the event of an output short circuit condition on +3.3V, +5V ,+12V1,+12V2,+12V3 or 12V4 12V5
output, the power supply will shutdown and latch off without damage to the power supply.The power.
supply shall return to normal operation after the short circuit has been removed and the power switch
has been turned off for more than 2 secondsthen turn-on again.
In the event of an output short circuit condition on –12V output, the power supply will not be damaged.
The power supply shall return to normal operation as soon as the short circuit has been removed.And
the power switch has been turned off for more than 2 seconds then turn-on again.
4.8. POWER SIGNAL
POWER GOOD @ 115/230V, FULL LOAD
POWER FAIL @115/230V, FULL LOAD
100 –500mSec.
1 mSec. minimum
DC OUTPUT
P.G. SIGNAL
Figure 1
T2 : RISETIME < 20mS
T3 : POWER GOOD DELAY TIME 100mS-500mS
T4 : POWER FAIL DELAY TIME > 1mS
T5 : POWER GOOD RISETIME < 10mS