Daikin FLXS35BVMB [135/180] Procedure

Daikin FLX35BVMB [135/180] Procedure
Indoor Unit SiBE05-311
126 Removal Procedure
1.8 Removal of the Fan Rotor / Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1
Remove the three fan
rotor covers. (Securing
hooks are located at A
and B-section.)
The right illustration
shows the opposite
side.
2
Disconnect the two
connection wirings
located at the rear side
of the fan motor and
unclamp the harness
from the clip.
Fan rotor
Fan rotor cover
A-section
(R3014)
B-section
(R3015)
Hooks at A-section
Hooks at B-section
(R3016)
Fan motor
(R3017)