Timberk AC TIM 36LC CF1/CF1-O1 [12/16] Ill i i
Содержание
- Household air conditioner 1
- Timberk 1
- Кондиционер бытовой 1
- Модели models 1
- Руководство по эксплуатации instruction manual 1
- Lililí i 2
- Важная информация 2
- Меры предосторожности 2
- ______ дуд_______ 3
- __ф2д 1ьй__ 3
- А _________________ 3
- Модель______________________________ 3
- Плреблммм наш кос обогрев вт 3
- Раоюд маема нюжнйт биж мз ч________ 3
- Технические характеристики 3
- Ж кий 5
- Il illi 6
- I i i i i i i i 8
- Сертификация 8
- Ill ii 9
- Hat btehmthb 1яунм1__________ 10
- Ill i i 10
- Power indicator 11 indicator of ventilation defrosting 12 the timer indicator 13 indicator alarm status 14 button controls in the absence remote control 15 the receiver of infrared signals from the remote control 11
- Ill i i 12
- Lililí 13
- I i i i i i i i 14
- Timberk 15
- Timberk 16
Похожие устройства
- PocketBook Pro 602 Burgundy Инструкция по эксплуатации
- Timberk AC TIM 48LC CF1/CF1-O1 Инструкция по эксплуатации
- Drazice OKHE 80-4kW Инструкция по эксплуатации
- PocketBook Pro 602 Grey Инструкция по эксплуатации
- Drazice OKHE 100-4kW Инструкция по эксплуатации
- Timberk AC TIM 60LC CF1/CF1-O1 Инструкция по эксплуатации
- PocketBook Pro 602 White Инструкция по эксплуатации
- Drazice OKHE 125-4kW Инструкция по эксплуатации
- Timberk AC TIM 09HDN S5/S5-01 Инструкция по эксплуатации
- PocketBook Pro 612 Grey Инструкция по эксплуатации
- Drazice OKHE 160-4kW Инструкция по эксплуатации
- Timberk TEC.PF2 EL IN Инструкция по эксплуатации
- PocketBook Pro 612 White Инструкция по эксплуатации
- Drazice OKHE 80-SMART Инструкция по эксплуатации
- Timberk TEC.PS1 EL IN Инструкция по эксплуатации
- PocketBook Pro 622 Black/White Инструкция по эксплуатации
- Drazice OKHE 100-SMART Инструкция по эксплуатации
- Timberk TEC.PS1 PGE IN Инструкция по эксплуатации
- Sony PRS-T1 Black Инструкция по эксплуатации
- Drazice OKHE 125-SMART Инструкция по эксплуатации
Ill Emergency control shall be used if the remote control board is lost or broken or batteries are low Using an emergency control button situated on the indoor unit control panel you may select COOL or AUTO mode of the conditioner work Pressing this button select a mode of the conditioner work AUTO COOL the conditioner is OFF AUTO again etc Figure 3 Description of the remote control board I I 21 Button AIR FLOW Using this button you may turn the blind swinging on and off 22 Button TIMER Using this button you may set the time for turning the conditioner on and off from 1 to 24 hours If the conditioner is off you may set the timefor automatic turning on in a set time interval And vice versa if the conditioner is on you may set the time for automatic turning off 23 Button SLEEP Using this button you may turn the sleep mode on and off In this mode thefan speed will be low 24 Button TURBO Using this button you may turn the turbo mode on and off In this mode the conditioner shows the maximum cooling in cool mode or heating in heat mode capacity This mode cannot be used in modes Auto Dry Fan 25 Button HOLD Using this button you may lock all other buttons of the control board including the button on indoor unit control panel To unlock this mode you should press this button once more 26 Button CLEAN This button is not used for th is series of conditioners 27 Button LAMP This button is not used for this series of conditioners Indication of the control board display shall correspond to selected modes Work with remote control board Mounting and replacement of batteries mount two LR03 batteries according to polarity indicated on the remote control board 16 Select mode button MODE Using this button you may select a required mode Auto Cool Dry Heat Fan 17 Button TEMP decrease increase for setting of the required air temperature from 16 to 32 C Using this button you may set the required airtemperature indoors 18 Button ON OFF Using this button you may turn the conditioner on or off 19 Button FAN SPEED Using this button you may select rotation speed of the indoor unitfan Auto High Middle Low In Auto mode the fan speed will change automatically In dry mode the fan speed will remain unchanged Low 20 Button SWING Using this button you may regulate position of air relief blinds and forward treated air to various directions alkaline In order to avoid malfunction of the remote control board do not insert used batteries or batteries of various types If the conditioner is not used for a long time remove batteries from the board orelse electrolyte may leak and damage the board In normal operation of the conditioner average service life of batteries will be about a half year Replace batteries if command receiving is not confirmed with an audio signal or if the display does not show a sign of command transfer When generating commands from the remote control board point an IRradiator on a remote control signal receiver situated on the indoor unit Hold the remote control board at the distance of no more than 8 m from the indoor unit