7. PLUMBING FIXTURE
The heater is designed for flow (non-pressurised) plumbing system. This system enables water withdrawal
from one point only. Connection has to be performed as indicated on the figure for connecting to water
supply network. For flow connection system you need to use a combination faucet designed to this
purpose. Water inflow and outflow is indicated with different colours on the heater tubes. Cold water
inflow is indicated with blue, hot water outflow is indicated with red. Return valve has to be fixed on the
inflow tube in front of the combination faucet in order to avoid water outflow from the boiler if there is a
lack of water within the network.
If the water pressure in the water supply network exceeds 5 bars, a reduction valve must be installed in
front of the combination faucet.
When choosing a flow faucet pay special attention to the information provided by the manufacturer
regarding pressure reduction due to resistance that occurs when water passes through the combination
faucet. If the drain valve is fully opened, it must not exceed 0.2 bar. You are not allowed to fix any water
driven device or a water disperser on the combination faucet drain tube since this might cause increase of
the pressure in the heater boiler. Should you fail in adhering to these instructions, the heater may get
damaged.
The “above-supply-point” version The “below-supply-point” version
Explanation:
1 shut-off valve
2 reduction valve
3 back pressure valve H cold water
4, 4a flow combination faucet T - hot water
BTO 5 UP
BTO 5 IN
BTO 10 UP
BTO 5 IN
BTO 10 IN
BTO 10 IN