Icom IC-F80T [31/48] I position data transmission

Icom IC-F80T [31/48] I position data transmission
27
4
BIIS OPERATION
Available characters
NOTE: A decimal point can only be written with the CS-
F70/F1700
CLONING SOFTWARE
. Pre-programmed charac-
ters can be rewritten with the 10-keypad, except for the
decimal point, as it is not included in the transceiver char-
acter list, and cannot be displayed again.
Position data transmission
When the optional cable (OPC-966) and a GPS receiver is
connected to the transceiver, the position (longitude and lati-
tude) data can be transmitted automatically.
Ask your dealer or system operator for connection details.
The position data is transmitted when;
Status 24 message is received
*When the status 24 message, GPS request, is received.
Fully automatic
When automatic position transmission is enabled, send
the position data according to Time Marker and Interval
Timer settings.
PTT is released
When Send with Logoff is enabled.
-Set the Log-In/Offitem as L-OFF.
After sending a status message
When Send with Status is enabled.
After sending an SDM
When Send with SDM is enabled.
After sending status 22 (Emergency)
When Send with Emergency is enabled.
Key Characters
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
4