Data Rebuilding Operation
Front Panel Storage FSR202
20
Hot-swap and auto rebuilding features
Off-line back up: When the data is stored in FSR202, user can remove one of the hard drives as back up drive for data such as system operation file, secured
files, seldom modified files or image and music files. User can periodically insert hard drive back into FSR202 to execute automatic backup to protect system
from being hit by computer virus or to avoid the risk of having both hard drives failing at the same time.
When one of the two hard drives fails in FSR202, hard drive failure alerts will show up in both LCD display and the monitoring software. User can remove the
failed hard drive from the system while the system is still in operation without shutting down. If the failed hard drive is replaced shortly, the system will
automatically execute the Auto Rebuilding function without affecting the system operation and also any operation command from the user.
When FSR202 detects one hard drive missing or failed, the Buzzer will start BEEPING with the
1. LCD displaying the following message:
2. After replacing a new hard drive with the failed one, LCD will display the following messages :
3. A few seconds after inserting a new hard drive, LCD will display the data rebuilding progress :
4. When FSR202 completes its rebuilding, LCD should display the following message :
Hot-Swap und automatische Wiederherstellung
Offline-Sicherung: Wenn Daten im FSR202 gespeichert sind, können Sie eine der Festplatten als Sicherungsfestplatten für Daten, wie Systembetriebsdateien,
gesicherte Dateien, selten modifizierte Dateien oder Bild- und Musikdateien, herausnehmen. Sie können Festplatten regelmäßig wieder in den FSR202
einsetzen und zum Schutz des Systems vor Computerviren oder zur Vermeidung der Gefahr eines gleichzeitigen Ausfalls beider Festplatten automatische
Sicherungen durchführen.
Wenn eine der beiden Festplatten im FSR202 ausfällt, erscheinen Alarmmeldungen auf dem LCD-Display und in der Überwachungssoftware. Sie können die
ausgefallene Festplatte bei laufendem Betrieb aus dem System entfernen, ohne es herunterfahren zu müssen. Falls die ausgefallene Festplatte zeitnah ersetzt
wird, führt das System automatisch eine automatische Wiederherstellung durch, ohne den Systembetrieb oder Nutzerbefehle zu beeinträchtigen.
1. Wenn der FSR202 erkennt, dass eine Festplatte fehlt oder ausgefallen ist, beginnt der Summer zu piepen und folgende Meldung erscheint auf dem LCD:
2. Nach Auswechslung einer ausgefallenen Festplatte zeigt das LCD folgende Meldung:
3. Einige Sekunden nach Einsetzen einer neuen Festplatte zeigt das LCD den Fortschritt der Datenwiederherstellung an:
4. Nach der Wiederherstellung sollte das LCD folgende Meldung anzeigen:
Cambio en caliente y características de reconstrucción
Copia de seguridad fuera de línea: Cuando los datos se almacenan en el FSR202, el usuario puede retirar uno de los discos duros como disco de copia de
seguridad de datos como el archivo de funcionamiento del sistema, archivos seguros, archivos raramente modificados o archivos de imágenes y música. El
usuario puede insertar de forma periódica el disco duro de nuevo en el FSR202 para ejecutar una copia de seguridad automática para proteger al sistema de
un ataque de un virus de ordenador o para evitar los riesgos de que ambos discos duros fallen a la vez.
Cuando uno o dos discos duros fallen en el FSR202, aparecerán alertas de fallo de disco duro en la pantalla LCD y el programa de control. El usuario puede
extraer el disco duro con fallos del sistema mientras el sistema todavía está en funcionamiento sin apagarlo. Si el disco duro con fallos se reemplaza en poco
tiempo, el sistema ejecutará de forma automática la función de Auto Reconstrucción sin afectar el funcionamiento del sistema y tampoco cualquier comando
del usuario.
1. Cuando el FSR202 detecta que falta o falla un disco duro, el indicador acústico empezará a PITAR mientras el LCD muestra el siguiente mensaje:
2. Tras reemplazar el disco duro con fallo por un nuevo disco duro, el LCD mostrará los siguientes mensajes:
3. Unos segundos después de insertar un nuevo disco duro, el LCD mostrará el progreso de reconstrucción de los datos:
4. Cuando el FSR202 completa su reconstrucción, el LCD mostrará el siguiente mensaje:
Echange à chaud et fonction de reconstruction automatique
Sauvegarde hors ligne: Lorsque des données sont stockées sur la baie FSR202, l’utilisateur peut retirer l’un des supports de stockage, utilisé pour sauvegarder
des données importantes du système, des fichiers sécurisés, des photos ou des fichiers audio. Ce support peut être réinséré dans la baie FSR202 pour une
sauvegarde automatique ou pour éviter que les deux supports de stockage subissent une défaillance en même temps.
Lorsque l’un des deux supports de stockage insérés dans la baie FSR202 est défaillant, une alerte s’affiche sur l’écran LCD et dans le logiciel de contrôle.
L’utilisateur peut retirer le support défaillant sans éteindre le système au préalable. Si le support est remplacé rapidement, le système lancera la fonction de
reconstruction automatique du volume sans affecter les opérations effectuées par l’utilisateur.
1. Lorsque la baie FSR202 détecte qu’un support de stockage est manquant ou défaillant, le haut-parleur commencera à émettre un signal sonore et l’écran
LCD affichera le message ci-dessous:
2. Après le remplacement du support défaillant, l’écran LCD affiche les messages ci-dessous:
3. Quelques secondes plus tard, l’écran LCD affiche l’état de la phase de reconstruction du volume:
4. Lorsque la reconstruction du volume est complète, le message ci-dessous s’affiche:
RAID-1 degraded
Pri : X Sec : O
1.
Pri HDD : OK
Sec HDD : OK
4.
2.
3.
Pri HDD : OK
Sec HDD : Insert
Pri HDD : Insert
Sec HDD : OK
Rebuilding
Sec → Pri 32%
Rebuilding
Pri → Sec 32%
Содержание
- Front panel storage 1
- Fsr202 1
- Installation and system optimization guide 2
- Manual fsr202 t179 v1 目錄 2
- Fits two 2 sata 6 gbit s drives in one 5 5 drive bay individual metal key lock for each drive for extra security configurable raid 0 and raid 1 modes friendly lcd display with led indicators for system monitoring during operation at all times independent drive status led built in cooling fan for excellent heat dissipation compatible with all 2 drives up to 15mm thickness fully supports sata hot swap function 3
- Front panel storage fsr202 3
- Introduction 3
- Packaging contents 3
- S with 3
- Special features 3
- Specifications 3
- To accommodate pc user s need for more storage flexibility and convenience silverstone created a line of front bay storage products called the fs series among the more unique products in the series the fsr202 can support dual 2 sata drives with release handle made for hot swapping thus exchanging drives is extremely quick and easy it also has raid 0 1 function with a user friendly interface and independent led indicators to let users quickly discern drive status finally for security each drive tray is equipped with metal key lock for those that need to upgrade their current pc with more drives with enhanced capability silverstone s fsr202 series is a great choice 3
- Front panel storage fsr202 4
- Introduction 4
- Manual fsr202 t179 v1 2 4
- Front panel storage fsr202 5
- Manual fsr202 t179 v1 3 5
- Package contents and product views 5
- Front panel storage fsr202 6
- Manual fsr202 t179 v1 4 6
- Package contents and product views 6
- Front panel storage fsr202 7
- Indicadores led 7
- Indicateurs led 7
- Indicatori led 7
- Led anzeigen 7
- Led indicators 7
- Manual fsr202 t179 v1 5 7
- Product view front and back 7
- Front panel storage fsr202 8
- Led индикаторы 8
- Led 표시등 8
- Ledインジケーター 8
- Manual fsr202 t179 v1 6 8
- Product view front and back 8
- 灯号一览表 8
- 燈號一覽表 8
- Front panel storage fsr202 9
- Manual fsr202 t179 v1 7 9
- Operation information 9
- Front panel storage fsr202 10
- Hardware requirements and precautions 10
- Manual fsr202 t179 v1 8 10
- Front panel storage fsr202 11
- Hardware requirements and precautions 11
- Manual fsr202 t179 v1 9 11
- Front panel storage fsr202 12
- Hardware requirements and precautions 12
- Manual fsr202 t179 v1 10 12
- Figure 1 figure 2 internal case 13
- Front panel storage fsr202 13
- Hardware installation procedure 13
- Manual fsr202 t179 v1 11 13
- Front panel storage fsr202 14
- Hardware installation procedure 14
- Manual fsr202 t179 v1 12 14
- Front panel storage fsr202 15
- Hardware installation procedure 15
- Manual fsr202 t179 v1 13 15
- Front panel storage fsr202 16
- Manual fsr202 t179 v1 14 16
- Raid mode setting 16
- Front panel storage fsr202 17
- Manual fsr202 t179 v1 15 17
- Raid mode setting 17
- Computer setup 18
- Front panel storage fsr202 18
- Manual fsr202 t179 v1 16 18
- Computer setup 19
- Front panel storage fsr202 19
- Manual fsr202 t179 v1 17 19
- 1 1 2 2 20
- Front panel storage fsr202 20
- Hard drive status on lcd screen 20
- Manual fsr202 t179 v1 18 20
- Pri hdd ok f sec hdd ok 20
- Pri hdd ok sec hdd ok 20
- Pri hdd ok sec hdd ok t 20
- Raid 0 failure pri m sec o 20
- Raid 1 degraded pri x sec o 20
- Raid 1 failure double source 20
- Raid 1 failure pri x sec x 20
- Rebuilding sec pri 32 20
- Sst fsr202 raid 1 vxxxxxx x 20
- Front panel storage fsr202 21
- Hard drive status on lcd screen 21
- Manual fsr202 t179 v1 19 21
- Data rebuilding operation 22
- Front panel storage fsr202 22
- Manual fsr202 t179 v1 20 22
- Pri hdd insert sec hdd ok 22
- Pri hdd ok sec hdd insert 22
- Pri hdd ok sec hdd ok 4 22
- Raid 1 degraded pri x sec o 1 22
- Rebuilding pri sec 32 22
- Rebuilding sec pri 32 22
- Data rebuilding operation 23
- Front panel storage fsr202 23
- Manual fsr202 t179 v1 21 23
- Front panel storage fsr202 24
- Gui monitoring software and firmware update 24
- Manual fsr202 t179 v1 22 24
- Front panel storage fsr202 25
- Gui monitoring software and firmware update 25
- Manual fsr202 t179 v1 23 25
- Front panel storage fsr202 26
- Gui monitoring software and firmware update 26
- Manual fsr202 t179 v1 24 26
- Front panel storage fsr202 27
- Gui monitoring software and firmware update 27
- Manual fsr202 t179 v1 25 27
- Front panel storage fsr202 28
- Gui monitoring software and firmware update 28
- Manual fsr202 t179 v1 26 28
- Front panel storage fsr202 29
- Manual fsr202 t179 v1 27 29
- Questions answers 29
- Front panel storage fsr202 30
- Manual fsr202 t179 v1 28 30
- Questions answers 30
- Front panel storage fsr202 31
- Manual fsr202 t179 v1 29 31
- Questions answers 31
- Front panel storage fsr202 32
- Manual fsr202 t179 v1 30 32
- Questions answers 32
- Front panel storage fsr202 33
- Manual fsr202 t179 v1 31 33
- Questions answers 33
- Front panel storage fsr202 34
- Manual fsr202 t179 v1 32 34
- Questions answers 34
- Manual fsr202 t179 v1 保固 產品合格證 35
- Warranty 35
- 产品合格证 35
- 多溴二苯醚 pbde 多溴联苯 pbb 六价铬 cr vi 镉 cd 汞 hg 铅 pb 35
- 有毒有害物质 元素及其化学含量表 外接式儲存裝置 35
- 部件名称 35
- Manual fsr202 t179 v1 封底 36
Похожие устройства
- SilverStone FSR202 Технические характеристики
- SilverStone SST-FSR202 Инструкция по эксплуатации
- SilverStone SST-FSR202 Технические характеристики
- SilverStone FS204 Инструкция по эксплуатации
- SilverStone FS204 Технические характеристики
- SilverStone SST-FS204B Инструкция по эксплуатации
- SilverStone SST-FS204B Технические характеристики
- SilverStone FS208 Инструкция по эксплуатации
- SilverStone FS208 Технические характеристики
- SilverStone SST-FS208B Инструкция по эксплуатации
- SilverStone SST-FS208B Технические характеристики
- SilverStone FS212 Инструкция по эксплуатации
- SilverStone FS212 Технические характеристики
- SilverStone SST-FS212B Инструкция по эксплуатации
- SilverStone SST-FS212B Технические характеристики
- SilverStone FS202 Инструкция по эксплуатации
- SilverStone FS202 Технические характеристики
- SilverStone SST-FS202B Инструкция по эксплуатации
- SilverStone SST-FS202B Технические характеристики
- SilverStone PTS01 Инструкция по эксплуатации