Daikin EHVZ08S18CB3V [17/28] Configuration

Daikin EHVZ16S18CB3V [17/28] Configuration
5 Configuration
Installation manual
17
EHVZ04~16S18CB3V
Daikin Altherma – Low temperature split
4P401672-1E – 2018.02
Leaving water temperature: Emitter type
# Code Description
[A.3.1.1.7] [9-0B] Reaction time of the system:
Set for the main temperature zone
0: Quick. Example: Small water
volume and fan coils.
1: Slow. Example: Large water
volume, floor heating loops.
Depending on the system water volume
and the heat emitters type, the heat up
of a space can take longer. This setting
can compensate for a slow or a quick
heating system by adjusting the unit
capacity during the heat up cycle.
5.2.6 Domestic hot water control
# Code Description
[A.4.1] [6-0D] Domestic hot water Type:
0 (Reheat only): Only reheat operation
is allowed.
1 (Reheat + sched.): Same as 2, but
between the scheduled heatup cycles,
reheat operation is allowed.
2 (Scheduled only): The domestic hot
water tank can ONLY be heated
according to a schedule.
[A.4.5] [6-0E] The maximum temperature that users
can select for the domestic hot water.
You can use this setting to limit the
temperature at the hot water taps.
INFORMATION
There is a risk of space heating capacity shortage/comfort
problem (in case of frequent domestic hot water operation,
frequent and long space heating interruption will happen)
when selecting [6‑0D]=0 ([A.4.1] Domestic hot water
Type=Reheat only).
5.2.7 Contact/helpdesk number
# Code Description
[6.3.2] N/A Number that users can call in case of
problems.