Daikin EHVZ16S18CB3V [5/8] 5 04 08 _ 6 16 4p401673 1a 2017 4

Daikin EHVZ16S18CB3V [5/8] 5 04 08 _ 6 16 4p401673 1a 2017 4
5/8
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
└─ Heat sources
└─ Backup heater
A.5.1.1 [4-00] R/W 0~2
0: Disabled
1: Enabled
A.5.1.4 [5-01] R/W -15~35°C, step: 1°C
0°C
└─ System operation
└─ Auto restart
A.6.1 [3-00] R/W 0: No
1: Yes
└─ Preferential kWh rate
A.6.2.1 [D-00] R/W
0~3
0: None
2: BUH onl
y
A.6.2.2 [D-05] R/W 0: Forced off
1: As normal
└─ Pwr consumpt. Control
A.6.3.1 [4-08] R/W
0: No limitation
1: Continuous
2: Di
g
ital in
p
uts
A.6.3.2 [4-09] R/W 0: Current
1: Powe
r
A.6.3.3 [5-05] R/W 0~50 A, step: 1 A
50
A
A.6.3.4 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.5.1 [5-05] Amp. limits for DI Limit DI1 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.2 [5-06] Amp. limits for DI Limit DI2 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.3 [5-07] Amp. limits for DI Limit DI3 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.4 [5-08] Amp. limits for DI Limit DI4 R/W 0~50 A, step: 1 A
50
A
A.6.3.6.1 [5-09] kW limits for DI Limit DI1 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.2 [5-0A] kW limits for DI Limit DI2 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.3 [5-0B] kW limits for DI Limit DI3 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.4 [5-0C] kW limits for DI Limit DI4 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.7 [4-01] R/W
0~2
0: None
2: BUH
└─ Averaging time
A.6.4 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
└─ Boiler efficiency
A.6.A [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
└─ Emergency
A.6.C R/W
0: Manual
1: Automatic
└─ Overview settings
A.8 [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
A.8 [0-01] R/W [9-05]~[9-06]°C, step: 1°C
45°C
A.8 [0-02] R/W 10~25°C, step: 1°C
15°C
A.8 [0-03] R/W -40~5°C, step: 1°C
-10°C
A.8 [0-04] R/W
8
A.8 [0-05] R/W
12
A.8 [0-06] R/W
35
A.8 [0-07] R/W
20
A.8 [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
A.8 [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
A.8 [0-0D] R/W 10~25°C, step: 1°C
15°C
A.8 [0-0E] R/W -40~5°C, step: 1°C
-10°C
A.8 [1-00] R/W -40~5°C, step: 1°C
-10°C
A.8 [1-01] R/W 10~25°C, step: 1°C
15°C
A.8 [1-02] R/W
[9-01]~[9-00], step: 1°C
35°C
A.8 [1-03] R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
A.8 [1-04] R/W
1
A.8 [1-05] R/W
1
A.8 [1-06] R/W
20
A.8 [1-07] R/W
35
A.8 [1-08] R/W
22
A.8 [1-09] R/W
18
A.8 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
--
--
--
--
--
What is the averaging time for the outdoor temp?
Low ambient temp. for DHW WD curve.
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
--
--
--
--
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
--
Type
Amp. value
kW value
Priority
Equilibrium temp.
Allowed heaters
Forced pump OFF
Mode
Operation mode
(*5) *04/08*_
(*6) *16*
4P401673-1A - 2017.04