Metabo SKN 50 Инструкция по эксплуатации онлайн [11/44] 70470

Metabo SKN 50 Инструкция по эксплуатации онлайн [11/44] 70470
11
Your choices for lubrication:
a) by mist oiler
A complete service unit
includes a mist oiler and is
tted at the compressor.
b) by line oiler
A line oiler is installed on the
tool’s air inlet, which provides
the necessary oil for lubri-
cation.
O-rings damages or soiled.
Clean or replace O-rings, tighten
screws fully..
A. Air escapes between lid and housing:
Faults and possible causes Remedy
B. Fasteners are not driven all the way in:
Working pressure too low.
Cross section of air hose too small.
Tool not lubricated.
Increase air pressure in 0.5 bar
increments, until fasteners are
properly driven.
Min. 6 mm inner diameter required.
Clean parts and lubricate.
C. Fasteners are driven too far into the material:
Working pressure too high.
Reduce working pressure in steps
of 0.5 bar.
D. Fasteners project or are bend:
Tool not held down fi rmly enough.
Hold down tool more fi rmly or increase
working pressure, if necessary.
Nail strip jams and will not advance fully
forward.
Open bayonet lock. Remove jammed
nails and properly load suitable
nails.
E. Driver jammed with nail strip
5.2 Trouble shooting
c) manual lubrication
If neither a service unit nor
a line oiler exists in the pres-
surised air system, 3 -5
drops of pneumatic oil must
be given into the air inlet
before each use.
Store air tools in dry
rooms only.
Скачать