Metabo BasicAir 350 [13/109] Generating compressed air

Metabo BasicAir 350 [13/109] Generating compressed air
ENGLISH
13
Use only extension cables with suffi-
cient lead cross section (see "Technical
Sp
ecifications").
Do not stop the compressor by unplug-
ging, but switch OFF using the switch.
Unplug after use.
5.4 Generating compressed
air
1. Switch on the machine (42 or 43).
Wait until the maximum tank pres-
sure is reached (the compressor
shuts OFF
).
The tank pressure is indicated on the
tan
k pressure gauge (47).
BasicAir 250/350
PowerAir 350
2. Set pressure regulator (44) to re-
quired working pressure. The cur-
rent working pressure is indicated
on the regu
lated pressure gauge
(46).
A Caution!
The regulated pressure may not be set
hi
gher than the max. working pressure
of the connected air tools!
3. Connect air hose to compressed air
outlet
(45).
4. Connect air tool. You are now ready
to work with th
e air tool.
5. Switch the compressor OFF, if you
d
o not continue working immediate-
ly afterwards. Unplug after switching
OF
F.
6. Drain the condensate from the pres-
sure vessel once a day (48). To do
this, tilt the machine slightly.
ADanger!
Prior to all servicing:
Switch machine OFF.
Unplug power cable.
Wait until the compressor has come
to a comple
te stop.
Ensure the compressor and all air
too
ls and accessories connected to
it are relieved from pressure.
Let the device and all air tools and
accessories cool down.
After all servicing:
Check to see that all safety devices
a
re operational.
Make sure that no tools or other
parts
remain on or in the machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified spe-
cialists.
6.1 Periodic maintenance
A Caution!
On a new compressor pump, check the
tigh
tening torque of the cylinder head
bolts (see 'Technical Data') after the
first 50 and 250 hours of operation.
Prior to each use
Check air hoses for damage, re-
place if necessary.
Check all screwed connections for
tightness and tighten if necessary.
Check power supply cable for dam-
age and have replaced by a quali-
fied electrician if necessary.
Every 50 operating hours
Check air filter element (49) of com-
pressor pump, clean if necessary.
Check the oil level in the compressor
pump with the oil dip stick
(50)
and
refill oil if necessary.
(51)
Every 250 operating hours
Replace air intake filter element of
compressor pump.
Every 500 operating hours
Drain oil and fill with fresh oil.
Every 1000 operating hours
Have unit serviced by an authorized
service station. This will extend the
compressor's service life considera-
bly.
6.2 Machine storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all
con
nected air tools.
3. Drain condensate from pressure
vessel .
42 43
44
46
47
45
46
44
47
42
45
6. Care and Maintenance
48
49
50
51

Содержание

Скачать
Случайные обсуждения

Ответы 1

Какая мощность движка?
6 лет назад

Ответы 0

Стравливает воздух через реле
1 год назад

Ответы 1

Уровень масла в картере
4 года назад