Daikin FTXG35EVMAW [3/30] Safety precautions
![Daikin FTXG35EVMAS [3/30] Safety precautions](/views2/1761920/page3/bg3.png)
2
READ BEFORE OPERATION
Safety precautions
•
Keep this manual where the operator can easily find them.
•
Read this manual attentively before starting up the unit.
•
For safety reason the operator must read the following cautions carefully.
•
This manual classifies precautions into WARNING and CAUTION. Be sure to follow all precautions below: they are all
important for ensuring safety.
WARNING
•
In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or
corrosive gases, are detected near the unit.
•
It is not good for health to expose your body to the air flow for a long time.
•
Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will
cause injury.
•
Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric
shocks, fire etc.
For repairs and reinstallation, consult your Daikin dealer for advice and information.
•
Do not insert fingers, poles, or other objects into the moving parts of the front panel or the outlet vent panel.
•
The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for
some reason any refrigerant happens to leak into the room, make sure it does not come in
contact with any flame as of gas heaters, kerosene heaters or gas range.
•
If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.
When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.
•
Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or
fire. For installation, consult the dealer or a qualified technician.
•
In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and
turn off the breaker. And call your dealer for instructions.
CAUTION
•
The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the
earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.
•
In order to avoid any quality deterioration, do not use the unit for cooling precision instru-
ments, food, plants, animals or works of art.
•
Never expose little children, plants or animals directly to the air flow.
•
Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the
indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.
WARNING
If you do not follow these instructions exactly, the unit may
cause property damage, personal injury or loss of life.
CAUTION
If you do not follow these instructions exactly, the unit may
cause minor or moderate property damage or personal injury.
Never do. Be sure to follow the instructions.
Be sure to earth the air conditioner.
Never cause the air conditioner (including the remote
controller) to get wet.
Never touch the air conditioner (including the remote
controller) with a wet hand.
01_EN_3P166462-1.fm Page 2 Tuesday, September 20, 2005 5:08 PM
Содержание
- Daikin room air conditioner 1
- Models 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- I indoor unit 5
- Names of parts 5
- I outdoor unit 6
- I remote controller 7
- Attention 8
- I to set the batteries 8
- Preparation before operation 8
- Attention 9
- Caution 9
- Choose a place from where the signals reach the unit 9
- I to fix the remote controller holder on the wall 9
- I to operate the remote controller 9
- I turn on the power breaker 9
- Place the remote controller in the remote controller holder 9
- Preparation before operation 9
- Be careful not to cool heat the room too much keeping the temperature setting at a moderate level helps save energy cover windows with a blind or a curtain blocking sunlight and air from outdoors increases the cooling heating effect clogged air filters cause inefficient operation and waste energy clean them once in about every two weeks 10
- I to set the clock 10
- If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off 10
- Operation outside this humidity or temperature range may cause a safety device to disable the system 10
- Outdoor temperature 10 to 46 c indoor temperature 18 to 32 c indoor humidity 80 max 10
- Outdoor temperature 15 to 20 c indoor temperature 10 to 30 c 10
- Press clock button 10
- Recommended temperature setting 10
- The air conditioner always consumes 15 35 watts of electricity even while it is not operating 10
- Use the air conditioner in the following conditions 10
- _en_3p166462 1 fm page 9 tuesday september 20 2005 5 08 pm 10
- Auto dry cool heat fan operation 11
- I to change the temperature setting 11
- I to start operation 11
- I to stop operation 11
- Press mode selector button and select a operation mode 11
- Press on off button 11
- Press on off button again 11
- Press temperature adjustment button 11
- I to change the air flow rate setting 12
- Press fan setting button 12
- Adjusting the air flow direction 13
- I to 3 d airflow 13
- I to adjust the horizontal blade flap 13
- I to adjust the vertical blades louvers 13
- I to cancel 3 d airflow 13
- Cool dry the flap will go up heat the flap will go down 14
- I to cancel comfort airflow operation 14
- I to start comfort airflow operation 14
- Press comfort airflow button 14
- Press comfort airflow button again 14
- The flap orientation will change preventing air from blowing directly on the occupants of the room 14
- I to cancel powerful operation 15
- I to start powerful operation 15
- Powerful operation 15
- I to cancel outdoor unit silent operation 16
- I to start outdoor unit silent operation 16
- Outdoor unit silent operation 16
- I to cancel the intelligent eye operation 17
- I to start intelligent eye operation 17
- Intelligent eye operation 17
- Press sensor button 17
- Press sensor button again 17
- Caution 18
- Intelligent eye is useful for energy saving 18
- Notes on intelligent eye 18
- I to cancel the off timer operation 19
- I to use off timer operation 19
- Timer operation 19
- Attention 20
- I to cancel on timer operation 20
- I to combine on timer and off timer 20
- I to use on timer operation 20
- Press cancel button 20
- Press on timer button 20
- Press on timer button again 20
- Press timer setting button until the time setting reaches the point you like 20
- Care and cleaning 21
- Caution 21
- I front panel 21
- I indoor unit outdoor unit and remote controller 21
- Filters 22
- I air filter 22
- Maintenance 22
- Replacement 22
- Titanium apatite photocatalytic air purifying filte 22
- After operation stops turn off the breaker for the room air conditioner 23
- Clean the air filters and set them again 23
- I before a long idle period 23
- Operate the fan only for several hours on a fine day to dry out the inside 23
- Take out batteries from the remote controller 23
- Case explanation 24
- These cases are not troubles 24
- Trouble shooting 24
- Case check 25
- Check again 25
- Call the service shop immediately 26
- Disposal requirements 26
- I the power cord is abnormally hot or damaged i an abnormal sound is heard during operation i the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently i a switch or a button often fails to work properly i there is a burning smell i water leaks from the indoor unit 26
- Turn the breaker off and call the service shop 26
- Warning 26
- We recommend periodical maintenance 26
- P166462 1 m05b042 30
- _cv_3p166462 1 fm page 2 monday october 3 2005 7 50 pm 30
Похожие устройства
- Daikin FTXG35EVMAW Сервис мануал
- Daikin FTXG25EVMAW Сервис мануал
- Daikin FTXG35EVMAS Инструкция по эксплуатации
- Daikin FTXG35EVMAS Сервис мануал
- Daikin FTXG25EVMAW Инструкция по эксплуатации
- Samsung SGH-J700 Руководство по эксплуатации
- Daikin 2MXS52E2V1B Инструкция по монтажу
- Daikin 2MXS52E2V1B Технические данные
- Daikin 3MXS52E2V1B Инструкция по монтажу
- Daikin 3MXS52E2V1B Технические данные
- Daikin 3AMX52E2V1B Инструкция по монтажу
- Daikin 2MXS52E3V1B Инструкция по монтажу
- Daikin 3MXS52E3V1B Инструкция по монтажу
- Daikin 3MXS52E3V1B Технические данные
- Daikin 3MXS52E3V1B Сервис мануал
- Daikin 3AMX52E3V1B Инструкция по монтажу
- Daikin 3AMX52E3V1B Сервис мануал
- Daikin 3AMX52E4V1B Инструкция по монтажу
- Daikin 3AMX52E4V1B2 Инструкция по монтажу
- Philips SHO9554 Инструкция по эксплуатации